全文获取类型
收费全文 | 117篇 |
免费 | 6篇 |
国内免费 | 1篇 |
专业分类
安全科学 | 1篇 |
废物处理 | 13篇 |
环保管理 | 9篇 |
综合类 | 3篇 |
基础理论 | 18篇 |
污染及防治 | 69篇 |
评价与监测 | 5篇 |
社会与环境 | 6篇 |
出版年
2022年 | 3篇 |
2021年 | 1篇 |
2019年 | 1篇 |
2018年 | 3篇 |
2017年 | 2篇 |
2016年 | 3篇 |
2015年 | 4篇 |
2014年 | 5篇 |
2013年 | 21篇 |
2012年 | 4篇 |
2011年 | 3篇 |
2010年 | 6篇 |
2009年 | 5篇 |
2008年 | 4篇 |
2007年 | 9篇 |
2006年 | 7篇 |
2005年 | 7篇 |
2004年 | 7篇 |
2003年 | 5篇 |
2002年 | 6篇 |
2001年 | 5篇 |
2000年 | 4篇 |
1999年 | 3篇 |
1997年 | 1篇 |
1978年 | 2篇 |
1977年 | 1篇 |
1973年 | 1篇 |
1971年 | 1篇 |
排序方式: 共有124条查询结果,搜索用时 15 毫秒
111.
Chiang BC Wey MY Liu KY 《Journal of the Air & Waste Management Association (1995)》2005,55(2):181-193
This study focuses on the control of particulates with a fluidized-bed filter in exhaust gas stream. The fluidized-bed filter classified in the granular bed filtration technology was employed to demonstrate the performance for removal of fly ash at indicated operating velocities, fixed bed heights, and bed temperatures; then the collecting mechanisms of particulates by fluidized-bed filter were studied. The size distribution of fly ash passing through the fluidized-bed filter was also analyzed. The results indicate that at higher operating velocities and fixed bed heights, the removal of fly ash is more efficient and inertial impaction is the main mechanism when the fluidized-bed is operated at room temperature (25 degrees C). While operating at higher temperatures (200 degrees C), efficiency of 93.2% to 99.4% can be achieved for submicron particles. It is supposed to be the diffusion mechanism that is responsible for collecting such small particles, and high temperature is a favorable condition because of diffusion. 相似文献
112.
The reuse of biosludge as an adsorbent from a petrochemical wastewater treatment plant 总被引:1,自引:0,他引:1
Chiang HL Choa CG Chen SY Tsai MC 《Journal of the Air & Waste Management Association (1995)》2003,53(9):1042-1051
Biosludge was obtained from a petrochemical industry's biological wastewater treatment plant. Zinc chloride (ZnCl2) was used as a sludge activation agent during the pyrolytic process. Scanning electron microscope (SEM) image photographs, element composition, surface functional group, and pore structure were analyzed for the sludge adsorbent characteristics. Results indicated the proper ZnCl2-immersed concentration, pyrolytic temperature, and time could produce adsorbent from the biosludge. The optimal conditions for a larger surface area adsorbent were 3 M ZnCl2-immersed sludge pyrolyzed at 600 degrees C for 30 min and washed with 3 N hydrochloric acid (HCl) solution and distilled water. The predominant pore size of the sludge adsorbent was the mesopore. 相似文献
113.
Chiang PC Chang EE Chang TC Chiang HL 《Journal of the Air & Waste Management Association (1995)》2005,55(3):326-341
This study investigated the relationships between meteorological data, pollution sources, and receptors over northern Taiwan. During the intensive sampling period in summer 1992, the weather was controlled predominantly by a Pacific subtropical high and by Typhoon Mark. During the other intensive sampling period in winter 1993, while a cold frontal system approached Taiwan, the northeasterly winds prevailed most of the time. The local circulation such as land-sea breeze only developed under weak synoptic environment. Particle concentrations and element composition in winter were higher than in summer. This can be attributed to the high convection of air mass, which leads to the vertical dispersion of pollutants in summer. In addition to the subtropical high pressure, typhoons are frequently accompanied with high-wind speeds and unstable weather conditions that also dilute and eliminate the pollutants. In winter, the prevailing northeasterlies might carry pollutants from Midland China. Furthermore, the anticyclone system develops a stagnant condition that easily leads to pollutant accumulation. In this case, the wind direction affected the source contribution of the receptor and the PM10 displays a higher correlation with coarse and fine particulate than meteorological parameters in summer. In addition, the mixing height shows a high correlation with PM10 in winter. 相似文献
114.
Methyl tert-butyl ether (MTBE) has been used as a fuel additive at levels of 2–11% in Taiwan for the past decade. The purpose of this additive is to enhance the octane, replace the use of lead-based anti-knock gasoline additives and reduce aromatic hydrocarbons. However, it is possible that oxygenated fuel has a potential health impact. To determine the air quality impact of MTBE, measurements were made of ambient MTBE and other gasoline constituents at a service station. Additionally, environmental conditions (wind speed, wind direction, and temperature, etc.) that could affect concentrations of emission constituents were measured. Gas samples were analyzed for target MTBE and volatile organic compounds, e.g., benzene and toluene. Ambient samples were collected using Tenax adsorbent tubes for mass spectrometric analysis at a service station located in Changhua County, Taiwan. The resulting measured ambient air concentrations were compared with Taiwans regulatory standards for hazardous air pollutants. Subsequently, the factors controlling the formation of high-VOC levels at the service station and in the residential neighborhoods were identified. Additionally, the results can provide the Environmental Protection Agency (EPA) of Taiwan with useful information and prompt them to mandate this gas service station to install a refueling vapor recovery system. 相似文献
115.
Analysis of respirometric graphs for system diagnosis has recently drawn much attention due to the nature of the test being a fast method with reliable oxygen uptake (Ou) data. In this study, a new graphical analysis procedure is proposed, using the oxygen uptake rate (OUR) vs. Ou respirogram because of its distinct characteristics that provides easy visual inspection. The OUR plot is typically divided into two respiration phases, and each one of these phases can be simulated by a previously derived analytical equation. Based on the 2-phase model, five characteristic parameters (CPs) were derived for the OUR respirogram. Mathematically the 5 CPs can be related to the system parameters (SPs), including the four Monod kinetic parameters and two operating conditions (initial substrate and biomass concentration). Sensitivity analyses were then conducted to assess the 5 CPs for the level of effect caused by system parameters (SPs). This study also conducted respirometric tests under batch operation to evaluate the applicability of the graphical analysis method. Based on the 5 CPs estimated from the OUR respirogram of the tests, it can be concluded that respirometric tests normally experience the problems associated with initial lag, non-uniform seeding, and inadequate mixing. 相似文献
116.
The adsorption of volatile organic compounds (VOCs), exemplified by benzene and methylethylketone (MEK), onto seven different types of activated carbon was investigated. Results show that for benzene adsorption the adsorption characteristic energy, enthalpy, free energy and entropy are in the range 17.12-36.86, -20.8 to -44.7, -11.89 to -16.22 kJ/mole and -29.4 to -85.3 J/mole/K, respectively. For the adsorption of MEK, the adsorption characteristic energy, enthalpy, free energy and entropy are in the range 14.47-32.34, -18.3 to -40.8, -10.78 to -15.56 kJ/mole and -24.8 to approximately -60.3 J/mole/K, respectively. The adsorption enthalpy can be calculated indirectly from statistical thermodynamic method and directly from the immersion enthalpy method. The adsorption characteristic energy is calculated by the Dubinin-Astokhov equation. The free energy is calculated by the measured equilibrium adsorption constant. 相似文献
117.
The dechlorination of 2,4,6-trichlorophenol (TCP) in municipal sewage sludge with a chlorophenol (CP)-adapted consortium was investigated. Results show that dechlorination rates differed according to the source of the sludge samples used in the batch experiments. No significant differences in 2,4,6-TCP dechlorination were observed following treatment with inoculum at densities ranging from 10% to 50% (V/V), but a significant delay was noted at 5% (V/V) density. Overall, results show that the higher the 2,4,6-TCP concentration, the slower the dechlorination rate. The addition of acetate, lactate, pyruvate, vitamin B12 or manganese dioxide did not results in a significant change in 2,4,6-TCP dechlorination. Data collected from a bioreactor experiment revealed that pH 7.0 and a total solid concentration of 10 g/L were optimal for dechlorination. Dechlorination rates decreased significantly at higher agitation speeds. 2,4,6-TCP dechlorination was enhanced under methanogenic conditions, but it was inhibited under denitrifying and sulfate-reducing conditions. 相似文献
118.
Ying-Liang Chen Juu-En Chang Pai-Haung Shih Ming-Sheng Ko Yi-Kuo Chang Li-Choung Chiang 《Journal of environmental management》2010,91(9):1892-1897
The purpose of this study was to combine the physical pretreatments of grinding, sieving, and magnetic-separation processes to reclaim iron-rich materials from the desulfurization slag, and to use the remainder for cement clinker production. The iron-rich materials can be separated out efficiently by grinding for 30 min and sieving with a 0.3 mm mesh. The non-magnetic fraction of the particles smaller than 0.3 mm was in the majority, and proved to be suitable for use as a cement raw material. The raw mixes prepared with a pretreated desulfurization slag had a relatively high reactivity, and the temperature at which alite forms was significantly reduced during the clinkerization process. The clinkers produced with 10% desulfurization slag had a high level of alite and good grindability. Generally, the improvements in clinkerization and clinker grindability are beneficial to energy conservation in cement manufacture. 相似文献
119.
120.
In this study, samples were taken from six conventional water treatment plants for disinfection by‐products analysis. Results from the analysis revealed that trihalomethanes (THMs) concentrations in all samples were below regulatory levels (100 μg/L). Although the national standard for haloacetic acids (HAA5) has not yet been promulgated in Taiwan, samples from two water plants contained HAA5 concentrations exceeding the USEPA limit (MCL of HAA5 of Stage 1, 60 μg/L). THMs and HAA5 were found to be the major disinfection by‐products in all water treatment plants. It was noted that the concentration of HAA5 in most samples was higher than that of the trihalomathanes. However, the formation potential of THM (THMFP) was found to be higher than that of HAA (HAAFP). Good correlation also was found between THMFP (or THMFP) and HAA5 (or THMs). In evaluating the performance of the treatment processes, it was found that conventional water treatment processes followed by activated carbon were effective in removing disinfection by‐products (DBPs) from source water with pre‐ozonation. The treatment processes were at their optimum performance in removing contaminants when O3/TOC0 was held at 0.75. 相似文献