The removal of MCPA (4-chloro-2-methyl phenoxyacetic acid) from aqueous solutions by activated spent bleaching earth (SBE) was studied as a function of time, initial concentration, adsorbent concentration, and temperature. The Langmuir and Freundlich isotherms were fitted by the adsorption data obtained. The values of Langmuir and Freundlich constants were determined. The adsorption kinetics was described by the Lagergren equation. Mass transfer coefficient and thermodynamic parameters were also calculated. Column experiments were conducted and brekthrough capacities were found for different concentrations and different flow rates. The study demonstrates that acid-treated SBE could be used as an efficient adsorbent for the removal of MCPA-bearing wastewater effluents.  相似文献   
13.
In the current study it was aimed to investigate the toxicity of low doses of imidacloprid (IMI) on the reproductive organ systems of adult male rats. The treatment groups received 0.5 (IMI-0.5), 2 (IMI-2) or 8 mg IMI/kg body weight by oral gavage (IMI-8) for three months. The deterioration in sperm motility in IMI-8 group and epidydimal sperm concentration in IMI-2 and IMI-8 groups and abnormality in sperm morphology in IMI-8 were significant. The levels of testosterone (T) and GSH decreased significantly in group IMI-8 compared to the control group. Upon treatment with IMI, apoptotic index increased significantly only in germ cells of the seminiferous tubules of IMI-8 group when compared to control. Fragmentation was striking in the seminal DNA from the IMI-8 group, but it was much less obvious in the IMI-2 one. IMI exposure resulted in elevation of all fatty acids analyzed, but the increases were significant only in stearic, oleic, linoleic and arachidonic acids. The ratios of 20:4/20:3 and 20:4/18:2 were decreased and 16:1n-9/16:0 ratio was increased. In conclusion, the present animal experiments revealed that the treatment with IMI at NOAEL dose-levels caused deterioration in sperm parameters, decreased T level, increased apoptosis of germ cells, seminal DNA fragmentation, the depletion of antioxidants and change in disturbance of fatty acid composition. All these changes indicate the suppression of testicular function.  相似文献   
14.

Introduction

This study presents the performance evaluation of a tailor-made passive sampler developed for the monitoring of tropospheric ozone.

Methods

The performance of the passive sampler was tested in the field conditions in terms of accuracy, precision, blank values, detection limit, effects of some parameters such as sampling site characteristics and sampling period on the field blanks, self-consistency, experimental and theoretical uptake rates, shelf life and comparison with commercial passive samplers.

Results

There was an agreement (R 2?=?0.84) between the responses of passive sampler and the continuous automatic analyser. The accuracy of the sampler, expressed as percent relative error, was obtained lower than 15%. Method precision in terms of coefficient of variance for three simultaneously applied passive samplers was 12%. Sampler detection limit was 2.42???g?m?3 for an exposure period of 1?week, and the sampler can be stored safely for a period of up to 8?weeks before exposure. Satisfactory self-consistency results showed that extended periods gave the same integrated response as a series of short-term samplers run side by side. The uptake rate of ozone was found to be 10.21?mL?min?1 in a very good agreement with the theoretical uptake rate (10.32?mL?min?1). The results of the comparison study conducted against a commercially available diffusion tube (Gradko diffusion tube) showed a good linear relationship (R 2?=?0.93) between two passive samplers.

Conclusions

The sampler seems suitable to be used in large-scale measurements of ozone where no data are available or the number of existing automated monitors is not sufficient.  相似文献   
15.
This study describes the field evaluation of a tailor-made new glass passive sampler developed for the determination of NO(2), based on the collection on triethanolemine (TEA)-coated fibre filter paper. The sampler has been derived from a Palmes design. The overall uncertainty of the sampler was determined by using Griess-Saltzman ASTM D 1607 standard test method as a reference method. The agreement between the results of the passive sampler and the reference method was +/-7.90% with the correlation coefficient of 0.90. Method precision in terms of coefficient of variance (CV) for three simultaneously applied passive samplers was 8.80%. The uptake rate of NO(2) was found to be 2.49 ml/min in a very good agreement with the value calculated from theory (2.63 ml/min). Sampler detection limit was 1.99 microg/m(3) for an exposure period of 1 week and the sampler can be stored safely for a period of up to 6 weeks before exposure. A comparison of the sampler performance was conducted against a commercially available diffusion tube (Gradko diffusion tube). The results from the applied statistical paired t test indicated that there was no significant difference between the performances of two passive samplers (R (2) > 0.90). Also, another statistical comparison was carried out between the dark and transparent glass passive samplers. The results from the dark-colour sampler were higher than that from the transparent sampler (approximately 25%) during the summer season because of the possible photodegradation of NO(2)-TEA complex.  相似文献   
16.
Ambient gas and particle phase samples were collected during two sampling periods from a residential area of an industrialized city, Kocaeli, Turkey. The sampling occurred during winter months when structures were being heated, and summer months when structures were not being heated. Σ(13)PAH (gas + particle) concentrations ranged between 6.2 ng m(-3) (DahA) and 98.6 ng m(-3) (Phe) in the heating (winter) period and 3.0 ng m(-3) (BaA) and 35.1 ng m(-3) (Phe) in the non-heating (summer) period. Phe, Flt and Pyr were found to be at high concentrations in both sampling periods. Winter time to summer time concentration ratios for individual ambient PAH concentration ratios ranged between 1.2 (DahA) and 17.5 (Flu), indicating the effect of the emissions from residential heating on measured concentrations of PAHs, but great industrial plants and the only incinerator facility of Turkey are other important pollution sources around the city. Temperature dependence of gas phase PAHs was investigated using the Clausius-Clapeyron equation. A high slope obtained (5069.7) indicated the effect of the local sources on measured gas phase PAHs. Correlation of the supercooled vapor pressure (P) with the gas particle partitioning coefficient (K(p)) and particle phase fraction was also evaluated. The relationship between the meteorological parameters and individual PAH (gas + particle) concentrations was investigated further by multiple linear regression analysis. It was found that the temperature had a significant effect on all of the measured PAH concentrations, while the effects of the wind speed and direction were not significant on the individual PAHs. On the other hand, PAH concentrations showed a strong linear relationship with the ventilation coefficient (VC) which showed the influence of local sources on measured PAHs. Benzo[a]pyrene toxic equivalent (BaP(eq.)) concentrations were used for health risk assessment purposes. The winter period risk level (2.92 × 10(-3)) due to the respiratory exposure to PAHs was found to be almost 3 times higher than in the summer period (1.15 × 10(-3)).  相似文献   
17.
18.
19.
In this study, PM10 concentrations and elemental (Al, Fe, Sc, V, Cr, Mn, Co, Ni, Cu, Zn, As, Se, Mo, Ag, Cd, Sn, Sb, Ba, Pb, and Bi) contents of particles were determined in Düzce, Turkey. The particulate matter samplings were carried out in the winter and summer seasons simultaneously in both urban and sub-urban sampling sites. The average PM10 concentration measured in the winter season was 86.4 and 27.3 μg/m3, respectively, in the urban and sub-urban sampling sites, while it was measured as 53.2 and 34.7 μg/m3 in the summer season. According to the results, it was observed that the PM10 levels and the element concentrations reached higher levels, especially at the urban sampling site, in the winter season. The positive matrix factorization model (PMF) was applied to the data set for source apportionment. Analysis with the PMF model revealed six factors for both the urban (coal combustion, traffic, oil combustion, industry, biomass combustion, and soil) and sub-urban (industry, oil combustion, traffic, road dust, soil resuspension, domestic heating) sampling sites. Loadings of grouped elements on these factors showed that the major sources of the elements in the atmosphere of Düzce were traffic, fossil fuel combustion, and metal industry-related emissions.  相似文献   