全文获取类型
收费全文 | 118篇 |
免费 | 0篇 |
专业分类
安全科学 | 4篇 |
废物处理 | 4篇 |
环保管理 | 8篇 |
综合类 | 30篇 |
基础理论 | 10篇 |
污染及防治 | 50篇 |
评价与监测 | 8篇 |
社会与环境 | 4篇 |
出版年
2017年 | 2篇 |
2016年 | 2篇 |
2015年 | 1篇 |
2013年 | 12篇 |
2012年 | 9篇 |
2011年 | 8篇 |
2010年 | 2篇 |
2009年 | 6篇 |
2008年 | 6篇 |
2007年 | 11篇 |
2006年 | 13篇 |
2005年 | 11篇 |
2004年 | 4篇 |
2003年 | 7篇 |
2002年 | 6篇 |
2001年 | 6篇 |
2000年 | 3篇 |
1999年 | 1篇 |
1995年 | 1篇 |
1994年 | 2篇 |
1993年 | 1篇 |
1991年 | 1篇 |
1990年 | 1篇 |
1989年 | 1篇 |
1983年 | 1篇 |
排序方式: 共有118条查询结果,搜索用时 343 毫秒
101.
102.
103.
Yu-Ling wei Huei-Fang Hsieh Yao-Wen Yang Jyh-Fu Lee Wei-Shun Liang 《Journal of the Air & Waste Management Association (1995)》2013,63(4):411-436
Abstract Clay that contains kaolinite has been used extensively as a raw material for manufacturing of bricks and china at 900–1100 °C. This study used clay to stabilize the contaminant chromium(VI) [Cr(VI)] through a heating process at 500–1100 °C. X-ray absorption spectroscopic results indicated that the 500–900 °C heating process transformed hazardous Cr(VI) to nontoxic Cr(III); Cr2O3 was the species detected as most abundant. The 1100 °C heating process caused the formation of Cr2SiO5, which was not detected in the samples heated at 500–900 °C. Fourier transformed extended X-ray absorption fine structure spectra were fitted by use of WinXAS software. Phase shifts and backscatter(ing) amplitudes for specific atom pairs, based on the crystallographic data for CrO3 and Cr2O3, were theoretically calculated with the FEFF software. The processed XAS data show that the first shell coordination numbers were similar to each other as the temperature was increased from 500 to 900 °C and 1100 °C, implying that their Cr(III) crystallite size was relatively similar. The interatomic distance between the target center element and the first shell for the 500– 1100 °C samples was 1.98Å. The Debye-Waller factor for the 1100 °C sample was increased compared with the 500 and 900 °C samples and probably indicates the formation of Cr2SiO5. 相似文献
104.
In recent times, the State of New Jersey (USA) has been making attempts at promoting recycling as an environmentally friendly means of attaining self-sufficiency at waste disposal, and the state has put in place a 50% recycling target for its municipal solid waste stream. While the environmental benefits of recycling are obvious, a recycling program must be cost effective to ensure its long-term sustainability. In this paper, a linear programming model is developed to examine the current state of recycling in selected counties in Northern New Jersey and assess the needs to achieve the state's recycling goal in these areas. The optimum quantities of waste to be sent to the different waste facilities, which include landfills, incinerators, transfer stations, recycling and composting plants, are determined by the model. The study shows that for these counties, the gap between the current waste practices where the recycling rate stands at 32% and the state's goal can be bridged by more efficient utilization of existing facilities and reasonable investment in expanding those for recycling activities. 相似文献
105.
The purposes of this study were to assess the quality of rainstorm runoffs from an industrial park developed to accommodate
general industries in Taiwan and to investigate the possible contributors of pollutants in the runoffs. Rainstorm runoffs
from this industrial park were found to contain COD and TSS with average event mean concentrations of two events of 2,202.6
± 1,356 and 784.7 ± 409 mg/l, respectively. The pollution level of these runoffs was found to be tens of times higher than
that which may be contributed by accumulation of pollutants in top soils. Other possible sources of the pollutants were those
accumulated in rainwater discharge channels and those which overflow from individual pre-treatment plants within the industrial
lots. The assessment results are useful in devising the best management practices for the stormwater discharges. The heavy
loadings suggest that installations of additional runoff pollution control practices at different zones are necessary at this
and similar industrial parks. 相似文献
106.
Hsieh MK Chien SH Li H Monnell JD Dzombak DA Vidic RD 《Water environment research》2011,83(9):807-814
Passively treated abandoned mine drainage (AMD) is a promising alternative to fresh water as power plant cooling water system makeup water in mining regions where such water is abundant. Passive treatment and reuse of AMD can avoid the contamination of surface water caused by discharge of abandoned mine water, which typically is acidic and contains high concentrations of metals, especially iron. The purpose of this study was to evaluate the feasibility of reusing passively treated AMD in cooling systems with respect to corrosion control through laboratory experiments and pilot-scale field testing. The results showed that, with the addition of the inhibitor mixture orthophosphate and tolyltriazole, mild steel and copper corrosion rates were reduced to acceptable levels (< 0.127 mm/y and < 0.0076 mm/y, respectively). Aluminum had pitting corrosion problems in every condition tested, while cupronickel showed that, even in the absence of any inhibitor and in the presence of the biocide monochloramine, its corrosion rate was still very low (0.018 mm/y). 相似文献
107.
Industrial wastewater sludge was treated by microwave processes to enhance the stabilization of laden copper. The effects of additives, processing time, microwave adsorbents, moisture content, reaction atmosphere, and cooling gas were investigated. The stabilization results were significantly enhanced by metal powder additives, prolonged microwave processing time, proper moisture content, the addition of carbonaceous materials, and a reaction environment with inert gas. It was also found that the moisture content would increase the homogeneity of applied microwave energy, and thus achieve a better overall efficiency between stabilizing agents and copper. The added metal powders may reduce Cu(II) to Cu(0) in the sludge or TCLP. The resulting thermal energy of microwave radiation, and microarcing process and the oxidation heat of Al powder may also assist the transformation of Cu(II) into CuO and CuAl2O4 phases. Part of the sludge was vitrified within inert gas environment when the processing time was longer than 18 min and active carbon dosage was more than 3g. Reduction reactions also occurred in the hybrid microwave processes, leading to the reduction of sulfates and metal ions, and the formation of Cu2S and FeS. Moreover, the microwave radiation can also enhance the feasibility of co-treating of inorganic and organic solid waste. 相似文献
108.
Meng PJ Lee HJ Wang JT Chen CC Lin HJ Tew KS Hsieh WJ 《Environmental pollution (Barking, Essex : 1987)》2008,156(1):67-75
Before 2001, the ecological protection area in the Kenting National Park (KTNP), southern Taiwan, was poorly described. In this study, a set of four-year data (2001-2004) of seawater qualities at 19 sampling sites around the Nanwan Bay in the KTNP was used to explore anthropogenic impacts to ecological environment, especially coral reefs. The parameters of water quality were analyzed immediately after collection. The results showed that higher values of nutrients and suspended solids were attributed to the higher run-off around Nanwan Bay. The fluxes of nutrients and suspended solids were consistently correlated to rainfall. Hence, equations were developed to calculate nutrient fluxes and suspended solids by using only rainfall data. Our results show that suspended solids and ammonia were the dominant factors leading to the drop in coral coverage. In summary, the water quality in the intertidal zone of Nanwan Bay has been degraded and required greater attention. 相似文献
109.
PAH emission from the incineration of three plastic wastes 总被引:10,自引:0,他引:10
A batch-type, controlled-air incinerator was used for the treatment of polyvinyl chloride (PVC), high-density polyethylene (HDPE), and polypropylene (PP) plastic wastes. The concentration and composition of 21 individual polycyclic aromatic hydrocarbons (PAHs) in the raw wastes, flue gas (gas and particle phases), and ash were determined. Stack flue-gas samples were collected by a PAH stack-sampling system. Twenty-one individual PAHs were analyzed primarily by a gas chromatograph/mass spectrometer (GC/MS). The CO concentration correlated well with the total PAH (R2 > .89), and thus can be used as a surrogate indicator for PAH emission. Excess amounts of air supply in the incineration of plastic wastes could decrease not only the concentration of the PAHs in the bottom ash but also the emission factor (EF) of the total PAH in the stack flue gas. Of the three plastic wastes, HDPE was found to have the highest mean EF of the total PAHs (462.3 mg/kg waste) from the stack flue gas. Incinerating PVC would result in a higher EF of PAHs (195.4 mg/kg waste) in the bottom ash. When PVC plastic wastes were incinerated, higher-ringed PAHs constituted a larger percentage in the bottom ash as compared to those from PP and HDPE plastics. By judging the output and input (O/I) ratio of the PAHs from the incineration trials of plastic wastes, the PAHs involved in incineration of three plastic wastes were almost entirely destroyed; and a low residual amount between 0.00018 and 0.00032 remained in the emission. 相似文献
110.
A pregnant woman has two children affected by moderately severe Hb H disease due to compound heterozygosity of South-east Asian deletion and Constant Spring mutation. In her third pregnancy, transabdominal chorionic villus sampling was performed at the tenth gestational week to obtain fetal DNA. The polymerase chain reaction was used for detection of both the South-east Asian deletion and the Constant Spring mutation. Hb H disease was diagnosed in the fetus. After genetic counselling, the couple elected to have the pregnancy terminated. 相似文献