31.
C.S. Cheung Lei Zhu Zhen Huang 《Atmospheric environment (Oxford, England : 1994)》2009,43(32):4865-4872
Experiments were carried out on a diesel engine operating on Euro V diesel fuel, pure biodiesel and biodiesel blended with methanol. The blended fuels contain 5%, 10% and 15% by volume of methanol. Experiments were conducted under five engine loads at a steady speed of 1800 rev min−1 to assess the performance and the emissions of the engine associated with the application of the different fuels. The results indicate an increase of brake specific fuel consumption and brake thermal efficiency when the diesel engine was operated with biodiesel and the blended fuels, compared with the diesel fuel. The blended fuels could lead to higher CO and HC emissions than biodiesel, higher CO emission but lower HC emission than the diesel fuel. There are simultaneous reductions of NOx and PM to a level below those of the diesel fuel. Regarding the unregulated emissions, compared with the diesel fuel, the blended fuels generate higher formaldehyde, acetaldehyde and unburned methanol emissions, lower 1,3-butadiene and benzene emissions, while the toluene and xylene emissions not significantly different. 相似文献
32.
Residual levels of DDTs and PAHs in freshwater and marine fish from Hong Kong markets and their health risk assessment 总被引:12,自引:0,他引:12
Axial and ventral muscle from 10 each species of freshwater and marine fish purchased from markets in Hong Kong were analyzed for dichlorodiphenyltrichloroethane (total DDTs including DDE, DDD and DDT) and polycyclic aromatic hydrocarbons (PAHs). Among the 10 freshwater fish species, rice field eel (Monopterus albus) showed significantly higher levels of DDTs in both ventral (125 ng/g wet wt) and axial muscle (127 ng/g wet wt) than the other species. The highest concentration of PAHs was detected in catfish (Clarias fuscus), with 24.8 ng/g in ventral muscle and 9.1 ng/g in axial muscle. As to marine fish, snubnose pompano (Trachinotus blochii) showed significantly higher levels of DDT and its metabolites (1018 ng/g in ventral and 409 ng/g wet wt in axial tissues) than all other marine fish species. The overall concentrations of PAHs in marine fish species were 15.5-57.0 ng/g (axial muscle) and 18.1-118 ng/g wet wt (ventral muscle) where yellow seafin (Acanthopeyrus latus) and golden threadfin bream (Nemipterus virgatus) exhibited the highest concentrations of PAHs in the axial and ventral muscles, respectively. In general, results showed that levels of PAHs in Hong Kong market fish was low and do not expect to cause any concern for human consumption. However, the levels of DDTs in fish samples ranged from 1.10 to 1018 ng/g wet wt, and based on a fish consumption rate of 142.2g/day to calculate the screening value of 14.4 ng/g wet wt for human consumption (USEPA, 2000. Guidance for assessing chemical contaminant, data for use in fish advisories, vol. 1: fish sampling and analysis, third ed. EPA 823-R-95-007. Office of Water, Washington, DC), there were 9 out of 20 (45%) muscle samples of freshwater fish species and 14 out of 20 (70%) muscle samples of marine fish species had elevated levels of DDTs exceeded the screening value. It was also suggested to use ventral muscle for detecting concentrations of persistent organic pollutants in fish. 相似文献
33.
Assessment of Contamination By Percolation Of Septic Tank Effluent Through Natural and Amended Soils
Fly ash has been found to be a potential material for the treatment of municipal and industrial wastewater, and may be useful in the treatment of septic tank effluent. Laboratory columns (30 cm) were used to determine the sorption capacity and hydraulic properties of lagoon fly ash, loamy sand, sand, and sand amended by lagoon fly ash (30 and 60%) and red mud gypsum (20%). The removal of chemical oxygen demand (COD) was high in all column effluents (71–93%). Extent of nitrification was high in Spearwood sand, Merribrook loamy sand and 20% red mud gypsum amended Spearwood sand. However, actual removal of nitrogen (N) was high in columns containing lagoon fly ash. Unamended Spearwood sand possessed only minimal capacity for P sorption. Merribrook loamy sand and red mud gypsum amended sand affected complete P removal throughout the study period of 12 weeks. Significant P leakage occurred from lagoon fly ash amended sand columns following 6–10 weeks of operation. Neither lagoon fly ash nor red mud gypsum caused any studied heavy metal contamination including manganese (Mn), lead (Pb), zinc (Zn), cadmium (Cd) and chromium (Cr) of effluent. It can be concluded that Merribrook loamy sand is better natural soil than Spearwood sand as a filter medium. The addition of lagoon fly ash enhanced the removal of P in Spearwood sand but the efficiency was lower than with red mud gypsum amendment. 相似文献
34.
Cheung K Shafer MM Schauer JJ Sioutas C 《Journal of the Air & Waste Management Association (1995)》2012,62(5):541-556
To assess the impact of past, current and proposed air quality regulations on coarse particulate matter (CPM), the concentrations of CPM mass and its chemical constituents were examined in the Los Angeles Basin from 1986 to 2009 using PM data acquired from peer-reviewed journals and regulatory agency database. PM10 mass levels decreased by approximately half from 1988 to 2009 at the three sampling sites examined- located in downtown Los Angeles, Long Beach and Riverside. Annual CPM mass concentrations were calculated from the difference between daily PM10 and PM2.5 from 1999 to 2009. High CPM episodes driven by high wind speed/stagnant condition caused year-to-year fluctuations in the 99th/98th percentile CPM levels. The reductions of average CPM levels were lower than those of PM10 in the same period, therefore the decrease of PM10 level was mainly driven by reductions in the emission levels of PM2.5 (or fine) particles, as demonstrated by the higher annual reduction of average PM2.5 (0.92 microg/m3) compared with CPM (0.39 microg/m3) from 1999 to 2009 in downtown Los Angeles despite their comparable concentrations. This is further confirmed by the significant decrease of Ni, Cr, V and EC in the coarse fraction after 1995. On the other hand, the levels of several inorganic ions (sulfate, chloride and to a lesser extent nitrate) remained comparable. From 1995 to 2008, levels of Cu, a tracer of brake wear, either remained similar or decreased at a smaller rate compared with elements of combustion origins. This differential reduction of CPM components suggests that past and current regulations may have been more effective in reducing fugitive dust (Al, Fe and Si) and combustion emissions (Ni, Cr, V, and EC) rather than CPM from vehicular abrasion (Cu) and inorganic ions (NO3(-), SO4(2-) and Cl(-)) in urban areas. Implications: Limited information is currently available to provide the scientific basis for understanding the sources and physical and chemical variations of CPM, and their relations to air quality regulations and adverse health effects. This study investigates the historical trends of CPM mass and its chemical components in the Los Angeles Basin to advance our understanding on the impact of past and current air quality regulations on the coarse fraction of PM. The results of this study will aid policy makers to design more targeted regulations to control CPM sources to ensure substantial protection of public health from CPM exposure. Supplemental Materials: Supplemental materials are available for this article. Go to the publisher's online edition of the Journal of the Air & Waste Management Association for (1) details of the sampling sites and (2) the daily concentrations of high CPM/PM10 episodes. 相似文献
35.
The sorption of lead ions from aqueous solution onto chitosan has been studied. Equilibrium studies have been carried out to determine the capacity of chitosan for lead ions. The effects of solution pH and chitosan particle size on the sorption capacity have been studied.The experimental data were analyzed using three equilibrium isotherm correlations, namely, Langmuir, Freundlich and Redlich-Peterson equations. The linear correlation coefficients were determined for each isotherm and the Freundlich provided the best fit. In addition, error functions have been used to determine the alternative single component equilibrium isotherm parameters by non-linear regression due to the inherent bias in using the correlation coefficient from the linearization. This technique enables the "best fit" isotherm parameters to be used in the equilibrium equations for the sorption of lead ions on chitosan within the limits and assumptions of the various error analysis methods. 相似文献
36.
37.
A new method for collecting barnacle cement in the liquid state is described. This permits studies on the transformation of cement from liquid to solid states not heretofore possible. Preliminary analyses showed that polymerization, i.e., the in vitro change from a clear liquid to an opaque solid mass is not affected by temperatures ranging from-10° to 45°C, by diluting with distilled water up to two-fold, or by treating with selective enzymes; some chemical inhibitors induce the formation of a white precipitate, possibly indicating denaturation of the protein. It is concluded that the liquid cement contains all the necessary components for self-assembly, progressively changing from a clear liquid to an opaque rubbery insoluble mass. The polymerization process is time-dependent and requires no exogenous catalyst. A mechanism that may be involved in the adhesion process of the barnacle is suggested. 相似文献
38.
The ability of bone char to adsorb three metal ions, namely, copper(II), zinc(II) and cadmium(II) ions from wastewater has been studied. Three single-component equilibrium systems and three binary equilibrium systems have been measured experimentally. The three single-component equilibrium data were analyzed using the Langmuir and the Sips equilibrium isotherm equations. The Sips isotherm gave a better fit of the experimental data than the Langmuir isotherm based on the sum of squares errors (SSE) analysis. The Cu-Zn, Cu-Cd and Cd-Zn binary equilibrium experimental data were examined by incorporating the Langmuir and the Sips isotherm equations into the ideal adsorbed solution theory (IAST). The solution methods and the predicted results for the three binary systems at different metal ion compositions have been evaluated. In addition, the application of the IAST to the model prediction for the fixed bed system is presented. 相似文献
39.
Heavy metal concentrations in edible bivalves and gastropods available in major markets of the Pearl River Delta 总被引:6,自引:0,他引:6
IntroductionItisincreasinglydifficulttoconsidermarinepollutioninHongKongwithoutreferencetoGuangdongProvinceortheentirePearlRiverDelta.ThePearlRiverDeltaisnotonlyageomorphicalunitbutalsoageographicalunitandthescopeofthePearlRiverDeltashouldincludemajo… 相似文献
40.
Zhang W Bean M Benotto M Cheung J Ungar K Ahier B 《Journal of environmental radioactivity》2011,102(12):1065-1069
A high volume aerosol sampler ("Grey Owl") has been designed and developed at the Radiation Protection Bureau, Health Canada. Its design guidance is based on the need for a low operational cost and reliable sampler to provide daily aerosol monitoring samples that can be used as reference samples for radiological studies. It has been developed to provide a constant air flow rate at low pressure drops (∼3 kPa for a day sampling) with variations of less than ±1% of the full scale flow rate. Its energy consumption is only about 1.5 kW for a filter sampling over 22,000 standard cubic meter of air. It has been demonstrated in this Fukushima nuclear accident related aerosol radioactivity monitoring study at Sidney station, B.C. that the sampler is robust and reliable. The results provided by the new monitoring system have been used to support decision-making in Canada during an emergency response. 相似文献