There is concern about the hazard of acute residential CO exposures from portable gasoline-powered generators, which can result in death or serious adverse health effects in exposed individuals. To address this hazard, the U.S. Consumer Product Safety Commission has developed low CO emission prototype generators by adapting off-the-shelf emission control technologies onto commercially available generators. A series of tests was conducted to characterize the indoor CO concentrations resulting from portable generators operating in the attached garage of a research house under seven different test house/garage configurations. The tested generators include both unmodified and modified low CO emission prototypes. It was found that CO concentrations varied widely, with peak house CO concentrations ranging from under 10 ppm to over 10,000 ppm. The highest concentrations in the house resulted from operation of the unmodified generator in the garage with the garage bay door closed and the house access door open. The lowest concentrations resulted from operation of a modified low CO emission prototype in the garage with the garage bay door open and the house access door closed. These tests documented reductions of up to 98% in CO concentrations due to emissions from two low CO emission portable generators compared to a stock generator.
Implications: Improper portable generator use has caused 800 U.S. deaths in the past 14 years. Generators operated in attached garages can cause CO to quickly reach deadly levels. Two low-emission prototypes generators were tested and had CO emissions reduced by up to 98%. Low-emission generators can reduce the risk of consumer poisonings and deaths. 相似文献
The only documentation on the building downwash algorithm in AERMOD (American Meteorological Society/U.S. Environmental Protection Agency Regulatory Model), referred to as PRIME (Plume Rise Model Enhancements), is found in the 2000 A&WMA journal article by Schulman, Strimaitis and Scire. Recent field and wind tunnel studies have shown that AERMOD can overpredict concentrations by factors of 2 to 8 for certain building configurations. While a wind tunnel equivalent building dimension study (EBD) can be conducted to approximately correct the overprediction bias, past field and wind tunnel studies indicate that there are notable flaws in the PRIME building downwash theory. A detailed review of the theory supported by CFD (Computational Fluid Dynamics) and wind tunnel simulations of flow over simple rectangular buildings revealed the following serious theoretical flaws: enhanced turbulence in the building wake starting at the wrong longitudinal location; constant enhanced turbulence extending up to the wake height; constant initial enhanced turbulence in the building wake (does not vary with roughness or stability); discontinuities in the streamline calculations; and no method to account for streamlined or porous structures.
Implications: This paper documents theoretical and other problems in PRIME along with CFD simulations and wind tunnel observations that support these findings. Although AERMOD/PRIME may provide accurate and unbiased estimates (within a factor of 2) for some building configurations, a major review and update is needed so that accurate estimates can be obtained for other building configurations where significant overpredictions or underpredictions are common due to downwash effects. This will ensure that regulatory evaluations subject to dispersion modeling requirements can be based on an accurate model. Thus, it is imperative that the downwash theory in PRIME is corrected to improve model performance and ensure that the model better represents reality. 相似文献
Flora of the still unchanged or slightly modified floodplains is particularly valuable. Such are the natural, periodically flooded riparian ecosystems within the Mid-Pripyat river valley in Belarus. Distinctive elements of that area are ‘periodic islands’, which arise from the most elevated parts of the riverbed during flooding and have a specific microtopography. The aim of the research was to recognize floristic composition and ecological conditions of the ‘islands.’ Noted plants were mainly photophilous, by clearly varied in soil moisture, acidity and fertility requirements. 相似文献
A study was made of the composition of wastes collected from the pipes of the stormwater drainage system of Sorocaba, SP, Brazil (600 thousand inhabitants). A total of 10 samples weighing at least 100 kg each were sorted into 19 items to determine the fraction that can be considered natural (earth/sand, stones, organic matter, and water, the latter determined after oven-drying the samples) and the anthropogenic fraction (the remaining 15 items, especially construction and demolition wastes and packaging). Soil/sand was found to be the main item collected (52.5 % dry weight), followed by the water soaked into the waste (24.3 %), which meant that all the other wastes were saturated in mud, whose contents varied from 6.4 % (glass) to 87.2 % (metalized plastics packaging). In general, 83 % of the collected wastes can be classified as “natural,” but the remaining 17 % represent 2,000 kg of the most varied types of wastes discarded improperly every day on the streets of the city. This is an alarming amount of wastes that may clog parts of the drainage systems, causing troubles for all the population (like flooding) and must be strongly considered in municipal solid wastes management and in environmental education programs. 相似文献
Seasonal dynamics of heart rate variability in individuals of late summer and autumn generations have been studied in three rodent species kept in a vivarium: the striped field mouse (Apodemus agrarius), bank vole (Clethrionomys glareolus), and northern red-backed vole (Cl. rutilus). It has been shown that the cardiac function of the rodents in autumn and winter is mainly controlled by autonomic mechanisms: the heart rate is slow, cardiovascular control systems are relaxed. During the winter-spring transition, the role of central cardiovascular circuits increases because of the necessity to activate all body systems by spring. 相似文献
Both the ‘cascade model’ of ecosystem service provision and the Driver-Pressure-State-Impact-Response framework individually contribute to the understanding of human–nature interactions in social–ecological systems (SES). Yet, as several points of criticism show, they are limited analytical tools when it comes to reproducing complex cause–effect relationships in such systems. However, in this paper, we point out that by merging the two models, they can mutually enhance their comprehensiveness and overcome their individual conceptual deficits. Therefore we closed a cycle of ecosystem service provision and societal feedback by rethinking and reassembling the core elements of both models. That way, we established a causal sequence apt to describe the causes of change to SES, their effects and their consequences. Finally, to illustrate its functioning we exemplified and discussed our approach based on a case study conducted in the Alpujarra de la Sierra in southern Spain.
Electronic supplementary material
The online version of this article (doi:10.1007/s13280-015-0651-y) contains supplementary material, which is available to authorized users. 相似文献
It is commonly assumed that atmospheric oxidation of hydrocarbon particles or hydrocarbon coatings on particles leads to polar products and increased water uptake, altering atmospheric visibility and increasing the likelihood they will act as cloud condensation nuclei (CCN). We show here through laboratory experiments that increased water uptake depends on the 3-dimensional structure of the particles. Laboratory studies of particles formed during ozonolysis of surface-bound alkenes, present as terminally unsaturated self-assembled monolayers (C8= SAM) on a silica substrate, were carried out at room temperature and 1 atm pressure. SAMs were exposed to ~1013 O3 molecules cm?3 for 40 min and resultant particles were analyzed using single particle Fourier transform infrared micro-spectroscopy (micro-FTIR) and secondary ion mass spectroscopy (SIMS). Spectroscopy results show that –COOH and other polar groups are formed but are buried inside a hydrophobic shell, consistent with earlier observations (McIntire et al., 2005, Moussa et al., 2009) that water uptake does not increase after reaction of the terminal alkene with O3. These insights into the 3-D structure of particles formed on oxidation have important implications for the ability of secondary organic aerosols to act as CCN. In addition, the nature of the surface of the particles is expected to determine their uptake into biological systems such as the surface of the lungs. 相似文献