PROBLEM: Parents are an important potential influence on the driving safety of their children. This study examined the relationship of parental driving record on male and female offspring's at-fault collision risk. METHOD: Drivers aged 16-21 on the date of full licensure were selected from driver records and a matching process was used to identify putative parents in two-parent households. Poisson regression models were developed to predict at-fault collisions of male and female youth in the three years following full licensure from parents' at-fault collisions, speeding offenses, and other moving offenses in the four years prior to children's licensure. One set of models examined the relative risk associated with increasing numbers of maternal and paternal at-fault collisions and offenses. Other models examined the joint versus separate maternal and parental contributions. RESULTS: Controlling for region of residence, both mothers' and fathers' at-fault collisions were associated with an increased risk in both male and female youth at-fault collisions. Mothers' and fathers' speeding offenses were also associated with increased relative risk of at-fault collisions for both sons and daughters, while fathers' other moving offenses increased collision risk for sons but not daughters. DISCUSSION: Further research is required to identify how parental driving risk is transmitted to children. IMPACT ON INDUSTRY: (a) Parents of young children should be informed of their role in influencing their children's future driving risk; (b) The results identify risk factors that could be of interest to licensing authorities and the insurance industry. 相似文献
INTRODUCTION: Cycling accidents in Australia, especially those resulting in head injuries, are a substantive cause of death and disability; but despite legislation and evidence that helmets reduce the risk of head injury, few adolescents wear them. METHOD: This study employed a revised version of the Theory of Planned Behavior (TPB; [Ajzen, I. (1991). The theory of planned behavior. Organizational Behavior and Human Decision Processes, 50, 179-211]) to investigate the determinants of helmet use among a sample of adolescents. Participants in the initial data collection were 294 high school students in Year 8 and Year 11, with 266 completing a follow-up questionnaire measuring behavior over the previous two weeks. RESULTS: Social norms, perceptions of control, and past behavior significantly predicted intentions to use helmets and perceptions of control and past behavior predicted actual helmet use. CONCLUSIONS: Strengthening the routine of helmet use and building young people's confidence that they can overcome any perceived barriers to helmet use will improve adherence to helmet wearing behavior. 相似文献
Large cooking oil pool fires, occurring in industrial oil cookers, present a severe hazard to food processing plants due to their size and the large amount of hot oil involved. This paper reports a series of full-scale fire experiments conducted in a large industrial oil cooker mock-up. The characteristics of large cooking oil pool fires and the effect of oil depth and hood position in the oil cooker on fire growth were studied. The use of water mist for extinguishing large oil pool fires and their extinguishing performance under different discharge pressure and with different types of water mist systems were investigated. Experimental results showed that the cooking oil underwent a substantial expansion in volume during heating. The fires developed quickly once the oil auto-ignited. The fire growth rate was affected by the oil depth in the pan and the hood position in the oil cooker. The water mist fire suppression systems effectively extinguished large cooking oil fires and prevented them from re-igniting. Their extinguishing performance was determined by the type of water mist system, discharge pressure and hood position in the oil cooker. 相似文献
This paper presents detailed data on the thermal response of two 500 gal ASME code propane tanks that were 25% engulfed in a hydrocarbon fire. These tests were done as part of an overall test programme to study thermal protection systems for propane-filled railway tank-cars.
The fire was generated using an array of 25 liquid propane-fuelled burners. This provided a luminous fire that engulfed 25% of the tank surface on one side. The intent of these tests was to model a severe partially engulfing fire situation.
The paper presents data on the tank wall and lading temperatures and tank internal pressure. In the first test the wind reduced the fire heating and resulted in a late failure of the tank at 46 min. This tank failed catastrophically with a powerful boiling liquid expanding vapour explosion (BLEVE). In the other test, the fire heating was very severe and steady and this tank failed very quickly in 8 min as a finite rupture with massive two-phase jet release. The reasons for these different outcomes are discussed. The different failures provide a range of realistic outcomes for the subject tank and fire condition. 相似文献
This paper describes the results from a series of fire tests that were carried out to measure the effect of defects in thermal protection systems on fire engulfed propane pressure vessels.
In North America thermal protection is used to protect dangerous goods rail tank-cars from accidental fire impingement. They are designed so that a tank-car will not rupture for 100 min in a defined engulfing fire, or 30 min in a defined torching fire. One common system includes a 13 mm blanket of high-temperature ceramic fibre thermal insulation covered with a 3 mm steel jacket. Recent inspections have shown that some tanks have significant defects in these thermal protection systems. This work was done to establish what levels of defect are acceptable from a safety standpoint.
The tests were conducted using 1890 l (500 US gallon) ASME code propane pressure vessels (commonly called tanks in the propane industry). The defects tested covered 8% and 15% of the tank surface. The tanks were 25% engulfed in a fire that simulated a hydrocarbon pool fire with an effective blackbody temperature of 870 °C.
The fire testing showed that even relatively small defects can result in tank rupture if the defect area is engulfed in a severe fire, and the defect area is not wetted by liquid from the inside. A wall failure prediction technique based on uniaxial high-temperature stress rupture test data has been developed and agrees well with the observed failure times. 相似文献
The aim of the work is to outline a procedure of finding force-velocity (F–V) characteristics (F = f(V)) of individual skeletal muscles of the human locomotor system. The presentation is based on an example concerning extensors of the elbow joint: the lateral and long heads of triceps brachii (TBCIat and TBCIong). The experimental part of the procedure involves a natural movement of using the upper extremity to push an external object of variable, adjustable load, engaging both the elbow and shoulder joint.Five men aged 23 took part in the experiment. Their task was to push the handle of a physical pendulum whose moment of inertia could be adjusted within the range of 58 kg m2-450 kg m2, so as to give it maximum angular velocity. During each trial the movement of the trunk, of the upper extremity and of the pendulum was video recorded and the force applied with the hand to the handle of the pendulum was measured.In order to find the F–V characteristics a simulation model SHOULDER was used, which is capable of solving the synergy problem for muscles of the arm and the shoulder girdle.It was found that despite considerable dispersion of experimental points the respective regression lines revealed a clear tendency of decreasing muscle force for increased shortening velocity of the monoarticular head (TBCIat) and of increasing muscle force for increased lengthening velocity of the biarticular head (TBCIong) of the triceps brachii muscle. 相似文献
The study aimed to find out the influence of sweating on footwear insulation with a thermal foot model. Simultaneously, the influence of applied weight (35 kg), sock, and steel toe cap were studied. Water to 3 sweat glands was supplied with a pump at the rate of 10 g/hr in total. Four models of boots with steel toe caps were tested. The same models were manufactured also without steel toe. Sweating reduced footwear insulation 19–25% (30–37% in toes). During static conditions, only a minimal amount of sweat evaporated from boots. Weight affected sole insulation: Reduction depended on compressibility of sole material. The influence of steel toe varied with insulation. The method of thermal foot model appears to be a practical tool for footwear evaluation. 相似文献
This paper deals with research aimed at developing a method for ergonomic analysis of the driver’s workplace in an electric locomotive. It presents the structure of the diagnosis and its assumptions, and includes a re-evaluation of the questionnaire-expert method in ergonomic research. The article presents research data on weights and evaluations including their standard deviations for particular priority features. Ergonomic levels of the studied operator’s cabin in locomotives are compared. 相似文献