This paper assesses the status of coastal zones in the context of expected climate change and its related impacts, as well as current and future socioeconomic pressures and impacts. It is argued that external stresses and shocks relating to sea-level rise and other changes will tend to exacerbate existing environmental pressures and damage in coastal zones. Coastal zones are under increasing stress because of an interrelated set of planning failures including information, economic market, and policy intervention failures. Moves towards integrated coastal zone management are urgently required to guide the coevolution of natural and human systems. Overtly technocentric claims that assessments of vulnerability undertaken to date are overestimates of likely future damages from global warming are premature. While it is the case that forecasts of sea-level rise have been scaled down, much uncertainty remains over, for example, combined storm, sea surge, and other events. In any case, within the socioeconomic analyses of the problem, resource valuations have been at best only partial and have failed to incorporate sensitivity analysis in terms of the discount rates utilized. This would indicate an underestimation of potential damage costs. Overall, a precautionary approach is justified based on the need to act ahead of adequate information acquisition, economically efficient resource pricing and proactive coastal planning. 相似文献
This paper describes the results from a series of fire tests that were carried out to measure the effect of defects in thermal protection systems on fire engulfed propane pressure vessels.
In North America thermal protection is used to protect dangerous goods rail tank-cars from accidental fire impingement. They are designed so that a tank-car will not rupture for 100 min in a defined engulfing fire, or 30 min in a defined torching fire. One common system includes a 13 mm blanket of high-temperature ceramic fibre thermal insulation covered with a 3 mm steel jacket. Recent inspections have shown that some tanks have significant defects in these thermal protection systems. This work was done to establish what levels of defect are acceptable from a safety standpoint.
The tests were conducted using 1890 l (500 US gallon) ASME code propane pressure vessels (commonly called tanks in the propane industry). The defects tested covered 8% and 15% of the tank surface. The tanks were 25% engulfed in a fire that simulated a hydrocarbon pool fire with an effective blackbody temperature of 870 °C.
The fire testing showed that even relatively small defects can result in tank rupture if the defect area is engulfed in a severe fire, and the defect area is not wetted by liquid from the inside. A wall failure prediction technique based on uniaxial high-temperature stress rupture test data has been developed and agrees well with the observed failure times. 相似文献