首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   85篇
  免费   1篇
安全科学   11篇
废物处理   1篇
环保管理   28篇
综合类   19篇
基础理论   4篇
评价与监测   22篇
灾害及防治   1篇
  2023年   1篇
  2022年   1篇
  2021年   1篇
  2020年   3篇
  2019年   1篇
  2016年   4篇
  2014年   7篇
  2013年   4篇
  2012年   7篇
  2011年   6篇
  2009年   11篇
  2007年   12篇
  2006年   3篇
  2005年   1篇
  2004年   4篇
  2003年   3篇
  2001年   2篇
  2000年   2篇
  1999年   1篇
  1998年   2篇
  1997年   4篇
  1996年   1篇
  1995年   1篇
  1994年   1篇
  1993年   3篇
排序方式: 共有86条查询结果,搜索用时 93 毫秒
31.
A hypothesis is proposed how Low Frequency Electromagnetic Field (LF EMF) exposure can stimulate an immune response, based on recent insights in immunology. We hypothesize that the Immunent EMF treatment induces mild stress to cells, which then produce cytokines that function as alarms or so called danger signals for the immune system. In this way EMF treatment takes the place of multiplying pathogens, and the damage these cause, in the triggering of an immune response. In a first series of experiments in␣vitro common carp head kidney-derived phagocytes were used to determine ROS production as a measure for immune activation. Exposure to LF EMF signals (200–5,000 Hz) at 5 μT or 1.5 mT led to 42 or 33% increase in immune activity, respectively, compared to negative control values. EMF could also additionally stimulate chemically pre-stimulated samples up to 18% (5 μT) or 22% (1.5 mT). Significance of increase in ROS production in the total series was: p < 0.0001. In a second series of experiments in␣vitro commercial goldfish were used. Groups of fish were housed under equal conditions in at least four control tanks and 8–16 EMF-exposed tanks. Exposure was done with a predominantly vertical field at field strengths (rms) between 0.15 and 50 μT. Without treatment mortality was about 50% after 18 days, while the treatment at 5 μT reduced it to 20% on average. At field strengths 0.15, 0.5, 1.5, 5, 15 and 50 μT an equally strong effect was found. Reducing the field strength to 0.05, 0.06, 0.01 and 0.003 μT showed a gradually decreasing effect, which only at 0.003 μT is no longer statistically significant. Finally, in␣vitro experiments were done with 560 commercial broiler chickens exposed to infection pressure from coccidiosis. EMF exposure at 6.5 μT reduced intestinal lesions by 40% and improved feed conversion by 8%.  相似文献   
32.
Strata pressures are common potential troubles during coal mining, serious ones can cause great catastrophe. This paper presents a new comprehensive electromagnetic radiation (EMR) monitoring technique to monitor and predict these disasters. In this paper, we studied the relationship of EMR emitted by various, uniaxially loaded, coal rock samples (coal, rock, roof-coal-floor composite) in their whole deformation and failure processes to the applied loads, and found that EMR signal is linearly related to the applied loads, while the number of EMR pulses is a third power function of the applied loads. Therefore, EMR signal is capable of reflecting the stress (load) state, deformation and fracture strength, and internal stress state of coal rock mass. Based on the above, we proposed three methods for measuring rock pressure distribution, periodic pressure, and internal stress distribution of coal rock mass on working faces, and conducted field measurements and verifications. The results showed that (i) EMR has a certain correspondence to support resistance of working faces, and can reflect more accurately the face pressure distribution; (ii) in the mining impacted area located within 100 m in the front of working face, the stress distribution has unimodal and bimodal forms; (iii) EMR signal changes periodically with periodic pressure, and can be used to qualitatively observe and evaluate periodic pressure; (iv) tested with antenna in the borehole into coal rock mass, EMR signal can effectively reflect the internal stress distribution and shifting, which was verified by using traditional drilling cuttings method. In addition, EMR can also be used to check the effect of destress blasting as one of the emergency measures. In conclusion, the results are of practical significance for using EMR to monitor rock pressure and guiding safe underground mining.  相似文献   
33.
结合当前我国电磁环境管理的需求,分析了现有电磁环境标准的制定情况及存在的问题,提出以环境质量为核心,构建具有5个不同层次的电磁环境标准体系,包括电磁环境质量标准、电磁辐射排放(控制)标准、电磁环境监测标准、电磁环境基础标准和电磁环境管理技术规范。根据标准的定位、作用、特征及相互关系,提出了电磁环境标准制修订的相关建议。  相似文献   
34.
Occupational exposure to radiofrequency (RF) and static magnetic fields at magnetic resonance imaging (MRI) suites is of continuing concern to personnel who routinely work in this environment. Questions regarding the levels of occupational RF and static field exposure have increased with the increasing demand for anesthetics to be administered in this environment. The present study was thus designed towards addressing the above-mentioned problem by gaining information regarding exposure levels of clinical personnel at MRI units in South Africa. Three 1.5 MRI units in Bloemfontein, South Africa were utilized to evaluate the exposure of clinical personnel to the electromagnetic fields present in the MRI environment over a period of time and during different clinical MRI procedures. Three rounds of measurements of RF fields in the MRI environment were done. All the three measurement rounds were focused on the low frequencies, 5 Hz–32 kHz, as well as on the high frequencies, 300 kHz–40 GHz. First round measurements were done to establish the background of the RF fields in and around the magnet room during an MRI examination. Second round RF field measurements were done at a specific location, 1 m away from the bore on the right-hand side of the bed, in the MRI room. The third round measurements were of the same format as the second round, but the specific location was against the magnet bore. Two pieces of Narda Safety Test Solution instruments, the EFA-300 and EMR-300, were used to measure the electromagnetic and magnetic exposure fields generated from the MRI scanners. Results of the measurements indicate that the electromagnetic fields measured during different clinical procedures do not exceed the International Commission on Non-Ionizing Radiation Protection (2000) guidelines in these units. Results from round two and three showed that the RF and gradient exposure 1 m and up against the bore entrance does not exceed these guidelines (rms average over 6 min). Ongoing new developments in MRI scanning create the need for continuously monitoring exposure of patients and workers to the EMF fields in the MRI environment.  相似文献   
35.
The utility and the safety of the extremely low frequencies (ELF) electromagnetic fields in the treatment of numerous diseases have been demonstrated. Moreover, the effects of these fields seem to depend on their respective codes (frequency, intensity, waveform). We want to value the effects and the safety of the therapeutic application of a musically modulated electromagnetic field (TAMMEF) system, which field is piloted by a musical signal and its parameters (frequency, intensity, waveform) are modified in time, randomly varying within the respective ranges, so that all possible codes can occur during a single application. Sixty subjects, affected by shoulder periarthritis were enrolled in the study and randomly divided into three groups of 20 patients each: the first exposed to TAMMEF, the second exposed to ELF, the third exposed to a simulated field. All subjects underwent a cycle of 15 daily sessions of 30 min each and a clinical examination upon enrolment, after 7 days of therapy, at the end of the cycle and at a follow-up 30 days later. All the patients of TAMMEF group and ELF group completed the therapy without the appearance of side effects: they presented a significant improvement of the subjective pain and the functional limitation, which remained stable at the follow-up examination. In those exposed to a simulated field group, there was no improvement of the pain symptoms or articular functionality. This study suggests that the TAMMEF system is efficacious and safe in the control of pain symptoms and in the reduction of functional limitation in patients with shoulder periarthritis. Moreover, the effects of the TAMMEF system cover those produced by the ELF field.  相似文献   
36.
This article presents methods and results of interlaboratory comparison in the electromagnetic field (EMF) survey measurements performed by Electromagnetic Environment Protection Laboratory. Based on the results, the author analyzed factors affecting the precision of EMF measurements, in particular—difficult to estimate—the “human factor”. In practice, the human factor has never been taken into account in the EMF measurements accuracy estimations budget, and the author estimate the importance of this factor that may include even up to half of the total uncertainty of measurements. Taking into account all factors depredating the accuracy of measurements, the uncertainty of the survey EMF measurements was estimated at the level of 2–4 dB.  相似文献   
37.
卫星地球站电磁环境的影响预测   总被引:2,自引:0,他引:2  
陆继根 《上海环境科学》1998,17(6):38-39,41
对某卫星地球站划定近场,远场后,对近场内最大功率密度,远场轴向功率密度,近场地面功率密度作了预测,对天线轴向前方建筑物高度作了特别考虑,结果表明:近场内最大功率密度为629uw/m2,是GB8702-88《电磁辐射防护规定》职业照射导出限值的1.5倍,远场轴向3400米后,功率密度降到GB8702-88规定的公众照射导出限值的1/5以下;天线对地面的辐射环境影响较小,但轴向前方建筑物必须实行限高保护。  相似文献   
38.
广州市区广播电视发射塔电磁辐射调查   总被引:3,自引:1,他引:3  
为了解广州市区广东电视发射塔和广州电视发射塔电磁辐射状况,广州市环境监测中心站对电视发射塔周围的环境进行了监测。结果表明.两座电视发射塔周围电磁辐射水平随着距离的增加,呈现下降的趋势;两座广播电视发射塔周围高层建筑敏感点窗外电磁辐射水平随着楼层的增加.呈现上升的趋势。  相似文献   
39.
电磁处理水实验平台建设与研究   总被引:3,自引:0,他引:3  
通过对国内外磁处理水技术发展的调研工作,自行组建了一套可调节电源额定电压、电源频率、电场强度、磁化流速、磁作用时间的利用高梯度磁场处理工业水的实验平台,用该平台对炼铁厂循环冷却水进行了模拟处理实验,实验结果分析表明,该实验技术可以用来对磁作用机理作深入分析,并优化系统工艺参数.  相似文献   
40.
此文对板材电磁成形进行了较全面的实验研究,并对板材在成形过程中变形规律进行了分析,同时对成形效率进行了讨论,为电磁成形技术的推广应用奠定了基础。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号