ABSTRACT: Streamflow for 67 years was simulated for Coon Creek at Coon Valley, Wisconsin, for three conditions in the drainage basin: (1) conditions in the 1930s; (2) conditions in the 1970s, excluding flood-detention reservoirs; and (3) conditions in the 1970s, including flood-detention reservoirs. These simulations showed that the changes in agricultural practices over 40 years (1940–80) reduced the 100-year flood by 53 percent (from 38,900 to 18,300 cubic feet per second). The flood-detention reservoirs reduced the 100-year flood by an additional 17 percent (to 15,100 cubic feet per second). The simulation was accomplished by calibrating a precipitation-runoff model to observed rainfall and runoff during two separate periods (1934–40 and 1978–81). Comparisons of model simulations showed that differences between the model calibrations for the two periods were statistically significant at the 95 percent confidence level. 相似文献
ABSTRACT: Atrazine and atrazine-residue (atrazine + two metabolites - deethylatrazine and deisopropylatrazine) concentrations were examined to determine if consideration of these atrazine metabolites substantially adds to our understanding of the distribution of this pesticide in groundwater of the midcontinental United States. The mean of atrazine.residue concentrations was 53 percent greater than that of atrazine alone for those observations above the detection limit (> 0.05 μg/l). Furthermore, a censored regression analysis using atrazine-residue concentrations revealed significant factors not identified when only atrazine concentrations were used. Thus, knowledge of concentrations of these atrazine metabolites is required to obtain a true estimation of risk of using these aquifers as sources for drinking water, and such knowledge also provides information that ultimately may be important for future management policies designed to reduce atrazine concentrations in ground water. 相似文献
This paper describes the results from a series of fire tests that were carried out to measure the effect of defects in thermal protection systems on fire engulfed propane pressure vessels.
In North America thermal protection is used to protect dangerous goods rail tank-cars from accidental fire impingement. They are designed so that a tank-car will not rupture for 100 min in a defined engulfing fire, or 30 min in a defined torching fire. One common system includes a 13 mm blanket of high-temperature ceramic fibre thermal insulation covered with a 3 mm steel jacket. Recent inspections have shown that some tanks have significant defects in these thermal protection systems. This work was done to establish what levels of defect are acceptable from a safety standpoint.
The tests were conducted using 1890 l (500 US gallon) ASME code propane pressure vessels (commonly called tanks in the propane industry). The defects tested covered 8% and 15% of the tank surface. The tanks were 25% engulfed in a fire that simulated a hydrocarbon pool fire with an effective blackbody temperature of 870 °C.
The fire testing showed that even relatively small defects can result in tank rupture if the defect area is engulfed in a severe fire, and the defect area is not wetted by liquid from the inside. A wall failure prediction technique based on uniaxial high-temperature stress rupture test data has been developed and agrees well with the observed failure times. 相似文献