21.
● Coupling merits of SEE and ERH were explored by a laboratory-scale device. ● SEE promotes the soil electrical conductivity and ERH process. ● Preheating soil by ERH improves the soil permeability and SEE. ● Combined method is more energy-efficient for perchloroethylene extraction. In situ thermal desorption (ISTD) technology effectively remediates soil contaminated by dense nonaqueous phase liquids (DNAPLs). However, more efforts are required to minimize the energy consumption of ISTD technology. This study developed a laboratory-scale experimental device to explore the coupling merits of two traditional desorption technologies: steam-enhanced extraction (SEE) and electrical resistance heating (ERH). The results showed that injecting high-density steam (> 1 g/min) into loam or clay with relatively high moisture content (> 13.3%) could fracture the soil matrix and lead to the occurrence of the preferential flow of steam. For ERH alone, the electrical resistance and soil moisture loss were critical factors influencing heating power. When ERH and SEE were combined, preheating soil by ERH could increase soil permeability, effectively alleviating the problem of preferential flow of SEE. Meanwhile, steam injection heated the soil and provided moisture for maintaining soil electrical conductivity, thereby ensuring power stability in the ERH process. Compared with ERH alone (8 V/cm) and SEE alone (1 g/min steam), the energy consumption of combined method in remediating perchloroethylene-contaminated soil was reduced by 39.3% and 52.9%, respectively. These findings indicate that the combined method is more favorable than ERH or SEE alone for remediating DNAPL-contaminated subsurfaces when considering ISTD technology.  相似文献   
22.
油和水物理性能的差异是设计浮油回收设备的基础。依据两者导电率差异研制出全自动浮油回收机,适用于粘度较低的浮油回收。利用两者粘度的不同,生产出收油效率较高的盘片式自动浮油回收设备,特别适合于粘度较高的浮油回收。  相似文献   
23.
对某厂采用普通型板式电除尘器处理l0万t锌沸腾焙烧烟气,在使用不到一年时间,造成设备腐蚀,甚至腐烂,严重影响了沸腾焙烧和制酸的正常生产,而被迫废弃的原因进行了较详细的叙述与剖析,并在此基础上重新设计研制了1台与实际生产相适应的GW1-55P-4 型电除尘器,于1998年9月建成并一次试车投产成功.  相似文献   
24.
ABSTRACT: An approach, based on the realization of the vertical components of flow is presented to determine the free surface of gravity wells and the shape of salt-water upconing in artesian aquifers. The transitional stages from pumping fresh water to pumping salt water at the critical condition are discussed. Vertical hydraulic resistances, being determined and included in the flow domain, allow the use of the finite-difference approximation in a simple form. The suggested approach implies the use of either simple modeling or computing techniques.  相似文献   
25.
PROBLEM: CFOI and SOII data show that 2,287 U.S. workers died and 32,807 workers sustained days away from work due to electrical shock or electrical burn injuries between 1992 and 1998. METHOD: The narrative, work activity, job title, source of injury, location, and industry for each fatal electrical accident were examined. A primary causal factor was identified for each fatality. RESULTS: Electrical fatalities were categorized into five major groups. Overall, 44% of electrical fatalities occurred in the construction industry. Contact with overhead power lines caused 41% of all electrical fatalities. DISCUSSION: Electrical shock caused 99% of fatal and 62% of nonfatal electrical accidents. Comprising about 7% of the U.S. workforce, construction workers sustain 44% of electrical fatalities. Power line contact by mobile equipment occurs in many industries and should be the subject of focused research. Other problem areas are identified and opportunities for research are proposed. IMPACT ON INDUSTRY: Improvements in electrical safety in one industry often have application in other industries.  相似文献   
26.
PROBLEM: It is estimated that 5 to 10 arc flash explosions occur in electric equipment every day in the United States. In the mining industry the largest single injury category of electrical injuries are caused by non-contact electrical arcs. METHOD: This investigation progressed in two phases: (a) 836 Mine Safety and Health Administration (MSHA) reports of electric arcing incidents that occurred over a period of 11 years were reviewed, and (b) personal interviews were conducted with 32 individuals. A theoretical Safe Job Performance Model guided the study. RESULTS: Behavioral dimensions were identified and included the effect of worker experience, judgment and decision-making ability, behavioral and organizational controls, and safety culture. SUMMARY: The National Institute for Occupational Safety and Health (NIOSH) conducted an investigation of behavioral components associated with arc flash incidents and developed recommendations for interventions based on findings. IMPACT ON INDUSTRY: This study fills a vacuum in electrical training with a focus on the organizational and behavioral aspects of arc flash incidents. The research is cross-cutting in its scope, in that the results apply not only to mining and construction, but many other industries employing electricians. Although the majority of mine electrical injuries are the results of burns from electrical arcs, few miners are aware that such a hazard exists. A safety training program, which includes a video and an instructor's discussion guide, was developed for electricians based on this study's findings. "Arc Flash Awareness" was released in 2007 (DHHS NIOSH Publication No.2007-116D) and is available through 1-800 CDC INFO. Phone: 1-800 232-4636 or email cdcinfo@cdc.gov. It is also available from MSHA at MSHADistribution@dol.gov or 304-256-3257 (DVD-576). Private industry is producing Portuguese and Spanish language translations.  相似文献   
27.
This study analyzes the cell temperature and current density fields of a solid oxide fuel cell stack, in which the inlet flow rate along the stacking direction of the fuel is either a curved profile derived through hydraulics or a progressively decreasing profile. The results show that the temperature field was neglibibly affected by the non-uniform inlet profile of the fuel, but the current density distribution was apparently affected. The difference in current density distribution between the curved profile and the progressively decreasing profile was small in the case of an solid oxide fuel cell (SOFC) with 10 stacks, but became larger in an SOFC with 20 stacks. In the 10-stack SOFC, the difference of current density between the uniform inlet flow and the curved inlet flow was less than 3%, whereas the deviation in the curved profile was less than 12%. However, in a 20-stack SOFC, the difference of current density was over 20%, whereas the deviation in the curved profile was more than 50%. Comparing the results between the curved and the progressively decreasing inlet profile indicates that the current density difference was over 20% in the 20-stack SOFC, but below 1% in the 10-stack SOFC. Therefore, a progressively decreasing inlet profile can replace a curved profile for analyzing an SOFC stack when the number of stacks is less than 10.  相似文献   
28.
• Graphite bipolar electrodes act as an appropriate bed for the CDI process. • Activated carbon Coating improves the application of the electrodes. • CDI is an environmentally friendly method to apply for brackish water. • Initial concentration is the most important parameter in the CDI method. • CDI process in a batch-mode setup needs more development. This research investigates a capacitive deionization method for salinity reduction in a batch reactor as a new approach for desalination. Reductions of cost and energy compared with conventional desalination methods are the significant advantages of this approach. In this research, experiments were performed with a pair of graphite bipolar electrodes that were coated with a one-gram activated carbon solution. After completing preliminary tests, the impacts of four parameters on electrical conductivity reduction, including (1) the initial concentration of feed solution, (2) the duration of the tests, (3) the applied voltage, and (4) the pH of the solution, were examined. The results show that the maximum efficiency of electrical conductivity reduction in this laboratory-scale reactor is about 55%. Furthermore, the effects of the initial concentration of feed solution are more significant than the other parameters. Thus, using the capacitive deionization method for water desalination with low and moderate salt concentrations (i.e., brackish water) is proposed as an affordable method. Compared with conventional desalination methods, capacitive deionization is not only more efficient but also potentially more environmentally friendly.  相似文献   
29.
Mechanical pulping process is electrical energy intensive and results in low paper strength. Biomechanical pulping, defined as the fungal treatment of lignocellulosic materials prior to mechanical pulping, has shown at least 30% savings in electrical energy consumption, and significant improvements in paper strength properties compared to the control at a laboratory scale. In an effort to scale-up biomechanical pulping to an industrial level, 50 tons of spruce wood chips were inoculated with the best biopulping fungus in a continuous operation and stored in the form of an outdoor chip pile for 2 weeks. The pile was ventilated with conditioned air to maintain the optimum growth temperature and moisture throughout the pile. The control and fungus-treated chips were refined through a thermomechanical pulp mill (TMP) producing lightweight coated paper. The fungal pretreatment saved 33% electrical energy and improved paper strength properties significantly compared to the control. Since biofibers were stronger than the conventional TMP fibers, we were able to reduce the amount of bleached softwood kraft pulp by at least 5% in the final product. Fungal pretreatment reduced brightness, but brightness was restored to the level of bleached control with 60% more hydrogen peroxide. The economics of biomechanical pulping look attractive.  相似文献   
30.
This work focuses on the phenomenon of the immiscible two-phase flow of water and oil in saturated heterogeneous soil columns. The goal is to develop a fast and reliable method for quantifying soil heterogeneities for incorporation into the relevant capillary pressure and relative permeability functions. Such data are commonly used as input data in simulators of contaminant transport in the subsurface. Rate-controlled drainage experiments are performed on undisturbed soil columns and the transient response of the axial distribution of water saturation is determined from electrical measurements. The transient responses of the axial distribution of water saturation and total pressure drop are fitted with the multi-flowpath model (MFPM) where the pore space is regarded as a system of parallel paths of different permeability. The MFPM enables us to quantify soil heterogeneity at two scales: the micro-scale parameters describe on average the effects of pore network heterogeneities on the two-phase flow pattern; the macro-scale parameters indicate the variability of permeability at the scale of interconnected pore networks. The capillary pressure curve is consistent with that measured with mercury intrusion porosimetry over the low pressure range. The oil relative permeability increases sharply at a very low oil saturation (< 10− 3) and tends to a high end value. The water relative permeability decreases abruptly at a low oil saturation (~ 0.1), whereas the irreducible wetting phase saturation is quite high. The foregoing characteristics of the two-phase flow properties are associated with critical (preferential) flowpaths that comprise a very small percentage of the total pore volume, control the overall hydraulic conductivity, and are consistent with the very broad range of pore-length scales usually probed in soil porous matrix.  相似文献   