全文获取类型
收费全文 | 733篇 |
免费 | 7篇 |
国内免费 | 63篇 |
专业分类
安全科学 | 196篇 |
废物处理 | 19篇 |
环保管理 | 53篇 |
综合类 | 359篇 |
基础理论 | 35篇 |
污染及防治 | 82篇 |
评价与监测 | 53篇 |
社会与环境 | 4篇 |
灾害及防治 | 2篇 |
出版年
2023年 | 13篇 |
2022年 | 12篇 |
2021年 | 31篇 |
2020年 | 38篇 |
2019年 | 17篇 |
2018年 | 8篇 |
2017年 | 14篇 |
2016年 | 22篇 |
2015年 | 37篇 |
2014年 | 49篇 |
2013年 | 41篇 |
2012年 | 30篇 |
2011年 | 55篇 |
2010年 | 21篇 |
2009年 | 48篇 |
2008年 | 37篇 |
2007年 | 44篇 |
2006年 | 48篇 |
2005年 | 49篇 |
2004年 | 23篇 |
2003年 | 26篇 |
2002年 | 21篇 |
2001年 | 19篇 |
2000年 | 17篇 |
1999年 | 17篇 |
1998年 | 14篇 |
1997年 | 9篇 |
1996年 | 14篇 |
1995年 | 8篇 |
1994年 | 11篇 |
1993年 | 2篇 |
1992年 | 3篇 |
1991年 | 1篇 |
1990年 | 2篇 |
1987年 | 1篇 |
1973年 | 1篇 |
排序方式: 共有803条查询结果,搜索用时 0 毫秒
31.
A comprehensive study of the degradation of monuron, one of the phenylurea herbicides, was conducted by UV-Vis/WO3 process. It was found that hydroxyl radicals played a major role in the decay of monuron while other radicals (e.g. superoxide) and hole might also contribute to the decomposition of monuron. The oxidation path likely plays a major role in the generation of hydroxyl radicals. The effects of initial pH level, initial concentration of monuron, and inorganic oxidants on the performance of UV-Vis/WO3 process were also investigated and optimized. Comparison between monuron decay pathways by UV-Vis/WO3 and UV/TiO2 was conducted. The decay mechanisms, including N-terminus demethylation, dechlorination and direct hydroxylation on benzene ring, were observed to be involved in the oxidation of monuron in these two processes. Sixteen intermediates were identified during the photodegradation of monuron and degradation pathways were proposed accordingly. 相似文献
32.
Ozonation as final wastewater (WW) polishing step, following conventional activated sludge treatment is increasingly implemented in sewage treatment for contaminant degradation to prevent surface water pollution. While the oxidative degradation of chemicals has been extensively investigated, the in vivo toxicological characteristics of ozonated whole effluents are rarely a matter of research.In the present study, whole effluents were toxicologically evaluated with an in vivo test battery before and after full-scale ozonation and subsequent sand filtration on site at a treatment plant. One aquatic plant (duckweed, Lemna minor) and five invertebrate species of different systematic groups (Lumbriculus variegatus, Chironomus riparius, Potamopyrgus antipodarum, Daphnia magna) were exposed to the effluents in a flow-through-designed test system with a test duration of 7-28 d.None of the considered toxicity endpoints correlated with the pollutant elimination. A tendency towards an increased toxicity after ozonation was apparent in three of the test systems showing [statistically] significant adverse effects in the L. variegatus toxicity test (decrease in reproduction and biomass). After sand filtration, adverse effects were reduced to a similar level like after conventional treatment. Solely the Daphnia reproduction test revealed beneficial effects after ozonation in combination with sand filtration.Results of the test battery indicate the formation of adverse oxidation products during WW ozonation. L. variegatus appeared to be the most sensitive of the five test species. Sand filtration effectively removes or detoxifies toxic oxidation products, as toxic effects were subsequently reduced to the level after conventional treatment. 相似文献
33.
H.C. Arredondo ValdezG. García Jiménez S. Gutiérrez GranadosC. Ponce de León 《Chemosphere》2012,89(10):1195-1201
The degradation of paracetamol in aqueous solutions in the presence of hydrogen peroxide was carried out by photochemistry, electrolysis and photoelectrolysis using modified 100 pores per inch reticulated vitreous carbon electrodes. The electrodes were coated with catalysts such as TiO2 and CuO/TiO2/Al2O3 by electrophoresis followed by heat treatment. The results of the electrolysis with bare reticulated vitreous carbon electrodes show that 90% paracetamol degradation occurs in 4 h at 1.3 V vs. SCE, forming intermediates such as benzoquinone and carboxylic acids followed by their complete mineralisation. When the electrolysis was carried out with the modified electrodes such as TiO2/RVC, 90% degradation was achieved in 2 h while with CuO/TiO2/Al2O3/RVC, 98% degradation took only 1 h. The degradation was also carried out in the presence of UV reaching 95% degradation with TiO2/RVC/UV and 99% with CuO/TiO2/Al2O3/RVC/UV in 1 h. The reactions were followed by spectroscopy UV-Vis, HPLC and total organic carbon analysis. These studies show that the degradation of paracetamol follows a pseudo-first order reaction kinetics. 相似文献
34.
35.
Liqun Lv Yunshan Ge Zhe Ji Jianwei Tan Xin Wang Lijun Hao Zhiwei Wang Mengzhu Zhang Chunjie Wang Haidan Liu 《环境科学学报(英文版)》2020,32(2):155-164
On-road driving emissions of six liquefied natural gas(LNG) and diesel semi-trailer towing vehicles(STTVs) which met China Emission Standard IV and V were tested using Portable Emission Measurement System(PEMS) in northern China.Emission characteristics of these vehicles under real driving conditions were analyzed and proved that on-road emissions of heavy-duty vehicles(HDVs) were underestimated in the past.There were large differences among LNG and diesel vehicles, which also existed between China V vehicles and China IV vehicles.Emission factors showed the highest level under real driving conditions, which probably be caused by frequent acceleration, deceleration, and start-stop.NOx emission factors ranged from 2.855 to 20.939 g/km based on distance-traveled and 6.719–90.557 g/kg based on fuel consumption during whole tests, which were much higher than previous researches on chassis dynamometer.It was inferred from tests that the fuel consumption rate of the test vehicles had a strong correlation with NOx emission, and the exhaust temperature also affected the efficiency of Selected Catalytic Reduction(SCR) aftertreatment system, thus changing the NOx emission greatly.THC emission factors of LNG vehicles were 2.012–10.636 g/km, which were much higher than that of diesel vehicles(0.029–0.185 g/km).Unburned CH_4 may be an important reason for this phenomenon.Further on-road emission tests, especially CH_4 emission test should be carried out in subsequent research.In addition, the Particulate Number(PN) emission factors of diesel vehicles were at a very high level during whole tests, and Diesel Particulate Filter(DPF)should be installed to reduce PN emission. 相似文献
36.
Quinete NS de Oliveira Edos S Fernandes DR Avelar Ade S Santelli RE 《Environmental pollution (Barking, Essex : 1987)》2011,159(12):3604-3612
A superficial water quality survey in a watershed of the Paraíba do Sul River, the main water supply for the most populated cities of southeastern Brazil, was held in order to assess the impact of the expansion of agricultural activity in the near border of the Atlantic Rain Forest. The aim of this study was to investigate the presence of priority organochlorine pollutants in soils and superficial waters of Atlantic rainforest fragments in Teresópolis, Rio de Janeiro State. Soil sample preparations were compared by using ultrasound, microwave assisted extraction and Soxhlet extraction. Recoveries of matrix spiked samples ranged from 70 to 130%. Analysis of a certified soil material showed recoveries ranging from 71 to 234%. Although low concentrations of organochlorine residues were found in water and soil samples, this area is of environmental importance and concern, thus demanding a monitoring program of its compartments. 相似文献
37.
Polycyclic aromatic hydrocarbons are very stable compounds and tend to bioaccumulate in the environment due to their high degree of conjugation and aromaticity. Hydrous pyrolysis is explored as a technique for the treatment of industrial water containing PAH, using anthracene as a model compound. The reactivity of anthracene under a range of temperatures and durations are studied in this paper. Aliquots of 1.0-10.0 mg of anthracene in a range of 1.0-5.0 mL of H2O are subjected to hydrous pyrolysis under varied conditions of temperature, reagents and duration. The conditions include oxidising systems comprising distilled water, hydrogen peroxide and Nafion-SiO2 solid catalyst in water; and reducing systems of formic acid and formic acid/Nafion-SiO2/Pd-C catalysts to assess a range of redox reaction conditions. Oxygen in air played a role in some of the reaction conditions. Pyrolysed products were identified and quantified by the use of Gas Chromatography-Mass Spectrometry (GC-MS). The major products were anthrone, anthraquinone, xanthone from oxidation; and multiple hydro-anthracene derivatives from reductive hydogenation. The nature of reaction conditions influenced the extent of anthracene degradation. The products formed are more reactive (less stable) as compared to anthracene the starting material and will therefore be less persistent in the environment. 相似文献
38.
39.
煤与瓦斯突出影响因素评价分析的模糊层次分析方法 总被引:3,自引:3,他引:3
在综合分析煤与瓦斯突出的影响因素的基础上,采用模糊层次分析法(FAHP)建立了煤与瓦斯突出模糊层次分析模型并进行了实例分析,确定了煤与瓦斯突出各影响因素的权重系数。评价结果表明:地应力、地质构造、瓦斯压力等是影响煤与瓦斯突出的主要因素。为制定相应的煤与瓦斯突出防治措施,提供了科学的理论依据和切合实际情况的评价方法。 相似文献
40.
In the last two decades, several serious accidents at large-scale technological systems that have had grave consequences, such as that at Bhopal, have primarily been attributed to human error. However, further investigations have revealed that humans are not the primary cause of these accidents, but have inherited the problems and difficulties of working with complex systems created by engineers. The operators have to comprehend malfunctions in real time, respond quickly, and make rapid decisions to return operational units to normal conditions, but under these circumstances, the mental workload of operators rises sharply, and a mental workload that is too high increases the rate of error. Therefore, cognivitive human features such as situation awareness (SA)—one of the most important prerequisite for decision-making—should be considered and analyzed appropriately. This paper applys the SA Error Taxonomy methodology to analyze the role of SA in three different accidents: (1) A runaway chemical reaction at Institute, West Virginia killing two employees, injuring eight people, and requiring the evacuation of more than 40,000 residents adjacent to the facility, (2) The ignition of a vapor cloud at Bellwood, Illinois that killed one person, injured two employees, and caused significant business interruption, and (3) An explosion at Ontario, California injuring four workers and caused extensive damage to the facility. In addition, the paper presents certain requirements for cognitive operator support system development and operator training under abnormal situations to promote operators’ SA in the process industry. 相似文献