全文获取类型
收费全文 | 256篇 |
免费 | 3篇 |
国内免费 | 66篇 |
专业分类
安全科学 | 17篇 |
废物处理 | 5篇 |
环保管理 | 19篇 |
综合类 | 194篇 |
基础理论 | 37篇 |
污染及防治 | 43篇 |
评价与监测 | 7篇 |
社会与环境 | 3篇 |
出版年
2023年 | 8篇 |
2022年 | 6篇 |
2021年 | 12篇 |
2020年 | 11篇 |
2019年 | 16篇 |
2018年 | 9篇 |
2017年 | 8篇 |
2016年 | 12篇 |
2015年 | 19篇 |
2014年 | 12篇 |
2013年 | 10篇 |
2012年 | 13篇 |
2011年 | 17篇 |
2010年 | 7篇 |
2009年 | 11篇 |
2008年 | 10篇 |
2007年 | 20篇 |
2006年 | 17篇 |
2005年 | 21篇 |
2004年 | 18篇 |
2003年 | 8篇 |
2002年 | 11篇 |
2001年 | 6篇 |
2000年 | 10篇 |
1999年 | 12篇 |
1998年 | 7篇 |
1997年 | 3篇 |
1996年 | 2篇 |
1995年 | 2篇 |
1994年 | 4篇 |
1992年 | 1篇 |
1991年 | 1篇 |
1987年 | 1篇 |
排序方式: 共有325条查询结果,搜索用时 0 毫秒
81.
In this paper we tested if treating the lichen Xanthoria parietina with Sb-containing solutions causes Sb bioaccumulation as well as physiological and ultrastructural changes. Total and intracellular antimony content in Sb-treated samples increased progressively with increasing concentration in the treatment solutions. Incubation of X. parietina thalli with Sb at concentrations as low as 0.1 mM caused a decrease in sample viability, measured as intensity of respiratory activity, and damage to cell membranes, expressed in terms of membrane lipid peroxidation, as well as ultrastructural changes such as plasmolysis, impairment of the thylakoid system of the alga and cytoplasmic lipid droplets. The photosynthetic system hardly responded, at least under the tested experimental conditions. 相似文献
82.
The increasing use of nanomaterials incorporated into consumer products leads to the need for developing approaches to establish “quantitative structure–activity relationships” (QSARs) for various nanomaterials. However, the molecular structure as rule is not available for nanomaterials at least in its classic meaning. An possible alternative of classic QSAR (based on the molecular structure) is the using of data on physicochemical features of TiO2 nanoparticles. The damage to cellular membranes (units L−1) by means of various TiO2 nanoparticles is examined as the endpoint. 相似文献
83.
Nathalie Tanne Rui Xu Mingyue Zhou Pan Zhang Xiaomao Wang Xianghua Wen 《Frontiers of Environmental Science & Engineering》2019,13(2):19
84.
Tiezheng Tong Kenneth H. Carlson Cristian A. Robbins Zuoyou Zhang Xuewei Du 《Frontiers of Environmental Science & Engineering》2019,13(4):63
85.
50Hz低频环境磁场对细胞增殖的影响及其机理探讨 总被引:8,自引:0,他引:8
本文以细胞株LO2(人肝细胞)和CHL(中国仓鼠肺成纤维细胞)为研究对象,用50Hz正弦磁场以不同强度、不同时间作用于细胞。长时间作用后,2种细胞的增殖均受到抑制,但抑制程度与磁场作用量并非呈简单的线性关系;磁场短时间作用对细胞增殖无明显影响,但细胞膜的流动性变差,在磁场撤去后膜的流动性又有所恢复。这一现象说明,低频弱磁场引起宏观生物效应需要时间的积累。同时观察到磁场短时间作用导致的CHL细胞上表皮生长因子受体(EGFR)的聚集,这可能是低频弱磁场引起宏观生物效应的一种机制。 相似文献
86.
87.
Recent improvements in oily wastewater treatment: Progress, challenges, and future opportunities 总被引:1,自引:0,他引:1
Oily wastewater poses significant threats to the soil, water, air and human beings because of the hazardous nature of its oil contents. The objective of this review paper is to highlight the current and recently developed methods for oily wastewater treatment through which contaminants such as oil, fats, grease, and inorganics can be removed for safe applications. These include electrochemical treatment, membrane filtration, biological treatment, hybrid technologies, use of biosurfactants, treatment via vacuum ultraviolet radiation, and destabilization of emulsions through the use of zeolites and other natural minerals. This review encompasses innovative and novel approaches to oily wastewater treatment and provides scientific background for future work that will be aimed at reducing the adverse impact of the discharge of oily wastewater into the environment. The current challenges affecting the optimal performance of oily wastewater treatment methods and opportunities for future research development in this field are also discussed. 相似文献
88.
Municipal sewage from an oxidation ditch was treated for reuse by nanofiltration (NF) in this study. The NF performance was optimized, and its fouling characteristics after different operational durations (i.e., 48 and 169 hr) were analyzed to investigate the applicability of nanofiltration for water reuse. The optimum performance was achieved when transmembrane pressure = 12 bar, pH = 4 and flow rate = 8 L/min using a GE membrane. The permeate water quality could satisfy the requirements of water reclamation for different uses and local standards for water reuse in Beijing. Flux decline in the fouling experiments could be divided into a rapid flux decline and a quasi-steady state. The boundary flux theory was used to predict the evolution of permeate flux. The expected operational duration based on the 169-hr experiment was 392.6 hr which is 175% longer than that of the 48-hr one. High molecular weight (MW) protein-like substances were suggested to be the dominant foulants after an extended period based on the MW distribution and the fluorescence characteristics. The analyses of infrared spectra and extracellular polymeric substances revealed that the roles of both humic- and polysaccharide-like substances were diminished, while that of protein-like substances were strengthened in the contribution of membrane fouling with time prolonged. Inorganic salts were found to have marginally influence on membrane fouling. Additionally, alkali washing was more efficient at removing organic foulants in the long term, and a combination of water flushing and alkali washing was appropriate for NF fouling control in municipal sewage treatment. 相似文献
89.
As a routine measurement to alleviate membrane fouling, hydraulic cleaning is of great significance for the steady operation of ultrafiltration (UF) systems in water treatment processes. In this work, a comparative study was performed to investigate the effects of the composition of backwash water on the hydraulic cleaning performance of UF membranes fouled by humic acid (HA). Various types of backwash water, including UF permeate, Milli-Q water, NaCl solution, CaCl2 solution and HA solution, were compared in terms of hydraulically irreversible fouling index, total surface tension and residual HA. The results indicated that Milli-Q water backwash was superior to UF permeate backwash in cleaning HA-fouled membranes, and the backwash water containing Na+ or HA outperformed Milli-Q water in alleviating HA fouling. On the contrary, the presence of Ca2 + in backwash water significantly decreased the backwash efficiency. Moreover, Ca2 + played an important role in foulant removal, and the residual HA content closely related to the residual Ca2 + content. Mechanism analysis suggested that the backwash process may involve fouling layer swelling, ion exchange, electric double layer release and competitive complexation. Ion exchange and competitive complexation played significant roles in the efficient hydraulic cleaning associated with Na+ and HA, respectively. 相似文献
90.
The distribution of metallic elements in a submerged membrane bioreactor(MBR) was revealed at different temperatures using inductively coupled plasma-optical emission spectrometry(ICP-OES), and the role of extracellular polymeric substances(EPS) was probed by integrating scanning electron microscopy(SEM) with confocal laser scanning microscopy(CLSM) over long-term operation. More metallic elements in the influent were captured by suspended sludge and built up in the fouling layer at lower temperature. The concentration of metallic elements in the effluent was 5.60 mg/L at 10°C operational temperature, far lower than that in the influent(51.35 mg/L). The total contents of metallic elements in suspended sludge and the membrane fouling layer increased to 40.20 and 52.19 mg/g at 10°C compared to 35.14 and 32.45 mg/g at 30°C, and were dominated by the organically bound fraction. The EPS contents in suspended sludge and membrane fouling layer sharply increased to 37.88 and 101.51 mg/g at 10°C, compared to 16.87 and 30.03 mg/g at 30°C. The increase in EPS content at lower temperature was responsible for the deposition of more metallic ions. The strong bridging between EPS and metallic elements at lower temperature enhanced the compactness of the fouling layer and further decreased membrane flux. This was helpful for understanding the mechanism of membrane fouling at different operational temperatures and the role of EPS, and also of significance for the design of cleaning strategies for fouled membranes after long-term operation. 相似文献