When accounting the CO2 emissions responsibility of the electricity sector at the provincial level in China,it is of great significance to consider the scope of both producers’ and the consumers’ responsibility,since this will promote fairness in defining emission responsibility and enhance cooperation in emission reduction among provinces.This paper proposes a new method for calculating carbon emissions from the power sector at the provincial level based on the shared responsibility principle and taking into account interregional power exchange.This method can not only be used to account the emission responsibility shared by both the electricity production side and the consumption side,but it is also applicable for calculating the corresponding emission responsibility undertaken by those provinces with net electricity outflow and inflow.This method has been used to account for the carbon emissions responsibilities of the power sector at the provincial level in China since 2011.The empirical results indicate that compared with the production-based accounting method,the carbon emissions of major power-generation provinces in China calculated by the shared responsibility accounting method are reduced by at least 10%,but those of other power-consumption provinces are increased by 20% or more.Secondly,based on the principle of shared responsibility accounting,Inner Mongolia has the highest carbon emissions from the power sector while Hainan has the lowest.Thirdly,four provinces,including Inner Mongolia,Shanxi,Hubei and Anhui,have the highest carbon emissions from net electricity outflow- 14 million t in 2011,accounting for 74.42% of total carbon emissions from net electricity outflow in China.Six provinces,including Hebei,Beijing,Guangdong,Liaoning,Shandong,and Jiangsu,have the highest carbon emissions from net electricity inflow- 11 million t in 2011,accounting for 71.44% of total carbon emissions from net electricity inflow in China.Lastly,this paper has estimated the emission factors of electricity consumption at the provincial level,which can avoid repeated calculations when accounting the emission responsibility of power consumption terminals(e.g.construction,automobile manufacturing and other industries).In addition,these emission factors can also be used to account the emission responsibilities of provincial power grids. 相似文献
Unlike the European Union emission trade system (EU ETS), China’s pilot ETSs implemented diversified policy designs instead of using a uniform framework. Variance ratio test is used to evaluate the Efficient Market Hypothesis (EMH) in China’s carbon trading markets. The results of two versions of variance ratio tests indicate that the carbon trading market in Hubei is considered weak form efficient, and the socialist market economy does not necessarily lead to market inefficiency in carbon trading markets. Thin trading activities generate market frictions and bias the Efficient Market Hypothesis (EMH) tests. 相似文献
The increasing capacity of distributed electricity generation brings new challenges in maintaining a high security and quality of electricity supply. New techniques are required for grid support and power balance. The highest potential for these techniques is to be found on the part of the electricity distribution grid.
This article addresses this potential and presents the EEPOS project’s approach to the automated management of flexible electrical loads in neighborhoods. The management goals are (i) maximum utilization of distributed generation in the local grid, (ii) peak load shaving/congestion management, and (iii) reduction of electricity distribution losses. Contribution to the power balance is considered by applying two-tariff pricing for electricity.
The presented approach to energy management is tested in a hypothetical sensitivity analysis of a distribution feeder with 10 households and 10 photovoltaic (PV) plants with an average daily consumption of electricity of 4.54 kWh per household and a peak PV panel output of 0.38 kW per plant. Energy management shows efficient performance at relatively low capacities of flexible load. At a flexible load capacity of 2.5% (of the average daily electricity consumption), PV generation surplus is compensated by 34–100% depending on solar irradiance. Peak load is reduced by 30% on average. The article also presents the load shifting effect on electricity distribution losses and electricity costs for the grid user. 相似文献
We test for evidence that energy efficiency features are capitalized into home prices in three U.S. metropolitan areas. Using hedonic regressions and multiple matching procedures, we find that Energy Star certification is associated with higher sales prices in two of the markets: the Research Triangle region of North Carolina and Portland, Oregon. We find that local “green” certifications in Portland and in Austin, Texas, are also associated with higher prices and that the estimated price impacts are larger than those from Energy Star. Matching on observables proves to be important in some cases, reducing the estimated impacts compared with models without matching. We calculate the implied energy savings from the estimated premiums and find that, in the Research Triangle market, the Energy Star premiums approximately equal the savings that program is designed to achieve, but in Portland, the premiums are slightly greater than the program's savings due to low energy costs in the region. 相似文献