In the last years many efforts were made to transform standardized algal test protocols into low-cost microplate assays. While advantages were pointed out frequently, limitations are not systematically addressed, thus hindering a widespread utilisation. In this study a group of organic substances with a wide distribution of volatility (log KAW from −6.53 to −2.13) and lipophilicity (log KOW from 1.26 to 4.92) was investigated with respect to the influence of these physicochemical properties on their algal toxicity in different assays. Therefore the EC50 values were determined with a microplate assay based on ISO 8692 protocol and the results were compared with those of an established algal growth inhibition test conducted in air tight glass vessels. Using the ratio of the EC50 values, a clear connection between biological response and volatility as well as lipophilicity of test substances could be detected. Chemicals with a log KOW higher than 3 or a Henry coefficient log KAW higher than −4 were identified as less effective in the microplate assay than in the comparative assay. The loss in nominal concentration due to physicochemical properties could be shown to contribute to this using HPLC analysis. Consequently, when using microplate assay’s one should be aware that lipophilic and volatile chemicals might be underestimated in their toxicity, which could be indicated from evaluating related physicochemical properties modelled from structural information prior to an experimental investigation. 相似文献
This study focuses on the verification of test interpretations for different state analyses of diffusion experiments. Part 1 of this study identified that steady, quasi-steady and equilibrium state analyses for the through- and in-diffusion tests with solution reservoirs are generally feasible where the tracer is not highly sorptive. In Part 2 we investigate parameter identifiability in transient-state analysis of reservoir concentration variation using a numerical approach. For increased generality, the analytical models, objective functions and Jacobian matrix necessary for inverse analysis of transient-state data are reformulated using unified dimensionless parameters. In these dimensionless forms, the number of unknown parameters is reduced and a single dimensionless parameter represents the sorption property. The dimensionless objective functions are evaluated for individual test methods and parameter identifiability is discussed in relation to the sorption property. The effects of multiple minima and measurement error on parameter identifiability are also investigated. The main findings are that inverse problems for inlet and outlet reservoir concentration analyses are generally unstable and well-posed, respectively. Where the tracer is sorptive, the inverse problem for the inlet reservoir concentration analysis may have multiple minima. When insufficient measurement data is collected, multiple solutions may result and this should be taken into consideration when inversely analyzing data including that of inlet reservoir concentration. Verification of test interpretation by cross-checking different state analyses is feasible where the tracer is not highly sorptive. In an actual experiment, test interpretation validity is demonstrated through consistency between theory and practice for different state analyses. 相似文献
Objective: A novel anthropomorphic test device (ATD) representative of the 50th percentile male soldier is being developed to predict injuries to a vehicle occupant during an underbody blast (UBB). The main objective of this study was to develop and validate a finite element (FE) model of the ATD lower limb outfitted with a military combat boot and to insert the validated lower limb into a model of the full ATD and simulate vertical loading experiments.
Methods: A Belleville desert combat boot model was assigned contacts and material properties based on previous experiments. The boot model was fit to a previously developed model of the barefoot ATD. Validation was performed through 6 matched pair component tests conducted on the Vertically Accelerated Loads Transfer System (VALTS). The load transfer capabilities of the FE model were assessed along with the force-mitigating properties of the boot. The booted lower limb subassembly was then incorporated into a whole-body model of the ATD. Two whole-body VALTS experiments were simulated to evaluate lower limb performance in the whole body.
Results: The lower limb model accurately predicted axial loads measured at heel, tibia, and knee load cells during matched pair component tests. Forces in booted simulations were compared to unbooted simulations and an amount of mitigation similar to that of experiments was observed. In a whole-body loading environment, the model kinematics match those recorded in experiments. The shape and magnitude of experimental force–time curves were accurately predicted by the model. Correlation between the experiments and simulations was backed up by high objective rating scores for all experiments.
Conclusion: The booted lower limb model is accurate in its ability to articulate and transfer loads similar to the physical dummy in simulated underbody loading experiments. The performance of the model leads to the recommendation to use it appropriately as an alternative to costly ATD experiments. 相似文献