The increasing capacity of distributed electricity generation brings new challenges in maintaining a high security and quality of electricity supply. New techniques are required for grid support and power balance. The highest potential for these techniques is to be found on the part of the electricity distribution grid.
This article addresses this potential and presents the EEPOS project’s approach to the automated management of flexible electrical loads in neighborhoods. The management goals are (i) maximum utilization of distributed generation in the local grid, (ii) peak load shaving/congestion management, and (iii) reduction of electricity distribution losses. Contribution to the power balance is considered by applying two-tariff pricing for electricity.
The presented approach to energy management is tested in a hypothetical sensitivity analysis of a distribution feeder with 10 households and 10 photovoltaic (PV) plants with an average daily consumption of electricity of 4.54 kWh per household and a peak PV panel output of 0.38 kW per plant. Energy management shows efficient performance at relatively low capacities of flexible load. At a flexible load capacity of 2.5% (of the average daily electricity consumption), PV generation surplus is compensated by 34–100% depending on solar irradiance. Peak load is reduced by 30% on average. The article also presents the load shifting effect on electricity distribution losses and electricity costs for the grid user. 相似文献
In this study, an experimental investigation on the performance of a small-scale residential-size solar-driven adsorption (silica gel-water) cooling system that was constructed at Assiut University campus, Egypt is carried out. As Assiut area is considered as hot, arid climate, field tests for performance assessment of the system operation during the summer season are performed under different environmental operating conditions. The system consists of an evacuated tube with a reflective concentration parabolic surface solar-collector field with a total area of 36 m2, a silica gel-water adsorption chiller of 8 kW nominal cooling capacity, and hot and cold water thermal storage tanks of 1.8 and 1.2 m3 in volume, respectively. The results of summer season field test show that under daily solar insolation varying from 21 to 27 MJ/m2, the solar collectors employed in the system had high and almost constant thermal efficiency. The daily solar-collector efficiency during the period of system operation ranged from about 50% to 78%. The adsorption chiller performance shows that the chiller average daily coefficient of performance (COP) was 0.41 with the average cooling capacity of 4.4 kW when the cooling-water and chilled-water temperatures were about 31°C and 19°C, respectively. As the chiller cooling water is cooled by the cooling tower in the hot arid area, the cooling water is at a higher temperature than the design point of the chiller. Therefore, an experiment was carried out using the city water for cooling. The results show that an enhancement in the chiller COP by 40% and the chilling power by 17% has been achieved when the city water was 27.7°C. 相似文献