A nonstationary time-series model is used to examine the changes occurring at sampling stations on the Chicago Sanitary and Ship Canal. Using data from upstream sampling sites, downstream levels of dissolved oxygen, total dissolved solids, nitrates and nitrites, and ammonia are accurately predicted. The method is simple, insensitive to extreme values, and responsive to changes in the system. 相似文献
The oxygenated species, massively produced in the energy production plants based on combustion processes, constitute one of the most numerous categories of hazardous air pollutants. Therefore, development of real time diagnostic tools are needed in order to study their formation during combustion processes and to reveal their presence both in the exhaust and in the atmosphere. In this work, oxygenated compounds were identified inside fuel-rich premixed ethylene/air flames by means of ultraviolet fluorescence spectroscopy with the support of qualitative chemical analysis of the sampled combustion gases.
Strong band progression, typical of aldehydic functionality, were recognized in fluorescence spectra (λexc=355 nm) measured in the early oxidation region of premixed flames varying the equivalence ratio from 3.0 up 21.6. Downstream of the oxidation region, spectroscopic signatures of pyrolytic species were found to prevail on those peculiar of oxygenated compound. The position and the extension of the two main flame zones were found to depend on the flame conditions (C/O ratio) due to the effect of the C/O ratio on the temperature history along the flame axis. This correlation was interpreted on the basis of the measured axial temperature profiles. 相似文献