T-2 toxin (T-2), one of the naturally occurring mycotoxins, often accumulates in aquatic animals from contaminated feed. Shrimp (n?=?30 per group) were fed with different concentrations (0, 0.5, 1.5, 4.5 and 13.5?mg kg?1) of T-2 for 20?days. Changes in histopathology, fatty acid and water distribution of shrimp muscle were analyzed. Histopathology of shrimp muscle showed dose-dependent marked degenerative and necrotic changes on exposure to dietary T-2. The T-2 significantly (P?<?0.05) affected the muscle fatty acid composition. ∑SFA, ∑MUFA and ∑PUFA initially decreased and then increased slowly in the high-dosed groups. C16:0, C18:1n-9 and C18:2n-6 were the main saturated fatty acid (SFA), monounsaturated fatty acid (MUFA) and polyunsaturated fatty acid (PUFA), respectively. Also, T-2 significantly affected water distribution in shrimp muscle. High doses of T-2 reduced free water content, resulting in a reduction in the water holding capacity and hence changes to the shrimp muscle quality. Collectively, these results illustrated that T-2 significantly affects the fatty acid and water distribution, and also muscle histopathology, all of which would result in a reduction in the quality and nutritional value of shrimp. 相似文献
The increasing capacity of distributed electricity generation brings new challenges in maintaining a high security and quality of electricity supply. New techniques are required for grid support and power balance. The highest potential for these techniques is to be found on the part of the electricity distribution grid.
This article addresses this potential and presents the EEPOS project’s approach to the automated management of flexible electrical loads in neighborhoods. The management goals are (i) maximum utilization of distributed generation in the local grid, (ii) peak load shaving/congestion management, and (iii) reduction of electricity distribution losses. Contribution to the power balance is considered by applying two-tariff pricing for electricity.
The presented approach to energy management is tested in a hypothetical sensitivity analysis of a distribution feeder with 10 households and 10 photovoltaic (PV) plants with an average daily consumption of electricity of 4.54 kWh per household and a peak PV panel output of 0.38 kW per plant. Energy management shows efficient performance at relatively low capacities of flexible load. At a flexible load capacity of 2.5% (of the average daily electricity consumption), PV generation surplus is compensated by 34–100% depending on solar irradiance. Peak load is reduced by 30% on average. The article also presents the load shifting effect on electricity distribution losses and electricity costs for the grid user. 相似文献