首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   140篇
  免费   10篇
  国内免费   17篇
安全科学   27篇
废物处理   2篇
环保管理   22篇
综合类   41篇
基础理论   25篇
污染及防治   24篇
评价与监测   21篇
社会与环境   4篇
灾害及防治   1篇
  2023年   3篇
  2020年   7篇
  2019年   6篇
  2018年   4篇
  2017年   11篇
  2016年   11篇
  2015年   8篇
  2014年   4篇
  2013年   15篇
  2012年   11篇
  2011年   9篇
  2010年   10篇
  2009年   9篇
  2008年   10篇
  2007年   7篇
  2006年   7篇
  2005年   2篇
  2004年   4篇
  2003年   5篇
  2002年   7篇
  2001年   1篇
  2000年   7篇
  1999年   2篇
  1998年   3篇
  1996年   1篇
  1993年   1篇
  1989年   1篇
  1982年   1篇
排序方式: 共有167条查询结果,搜索用时 31 毫秒
131.
ABSTRACT: The purpose of this study was to evaluate the Better Assessment Science Integrating Point and Nonpoint Sources (BASINS) watershed management system. BASINS data were used with the NPSM model to predict discharge and sediment concentrations at the outlet of a 103 km2 Ohio watershed. It was concluded that the NPSM model should always be calibrated but only a few of the parameters provided with BASINS needed to be calibrated. For a three‐year study period, there was a 2 percent underestimation of discharge using area weighted precipitation values and a 25 percent overestimation using the single station data in BASINS. A comparison of observed and predicted monthly discharge resulted in an r2 of 0.86 with area‐weighted precipitation and an r2 of 0.74 with the single station data. Calibrating the model to substantially improve sediment predictions was unsuccessful and we concluded that a calibration period of one year was too short. For the three‐year study period, the r2 for sediment was 0.36 with a slope of 0.37 and an intercept of 18.8 mg/l. The mean observed and predicted sediment concentrations were 27.1 mg/l and 22.6 mg/l, respectively.  相似文献   
132.
Long‐term simulations of agricultural watersheds have often been done assuming constant land use over time, but this is not a realistic assumption for many agricultural regions. This paper presents the soil and water assessment tool (SWAT)‐Landuse Update Tool (LUT), a standalone, user‐friendly desktop‐based tool for updating land use in the SWAT model that allows users to process multi‐year land use data. SWAT‐LUT is compatible with several SWAT model interfaces, provides users with several options to easily prepare and incorporate land use changes (LUCs) over a simulation period, and allows users to incorporate past or emerging land use categories. Incorporation of LUCs is expected to provide realistic model parameterization and scenario simulations. SWAT‐LUT is a public domain interface written in Python programming language. Two applications at the Fort Cobb Reservoir Experimental Watershed located in Oklahoma and pertinent results are provided to demonstrate its use. Incorporating LUCs related to implementation of recommended conservation practices over the years reduced discharge, evapotranspiration, sediment, total nitrogen, and total phosphorus loads by 59%, 9%, 68%, 53%, and 88%, respectively. The user’s manual is included in this article as Supporting Information. The SWAT‐LUT executable file and an example SWAT project with three land use rasters and the user’s manual are available at the United States Department of Agriculture‐Agricultural Research Service Grazinglands Research Laboratory website under Software. Editor’s note : This paper is part of the featured series on Optimizing Ogallala Aquifer Water Use to Sustain Food Systems. See the February 2019 issue for the introduction and background to the series.  相似文献   
133.
确保主要行业主要污染物排放总量数据的准确性对制定总量减排和区域环境质量改善规划尤为重要.以济南某石化企业为例,对石油加工业常减压、催化裂化、延迟焦化、柴油加氢、硫磺回收等工艺二氧化硫产排污系数开展验证研究.将产排污系数与监测结果对比分析,发现该企业通过产排污系数计算的二氧化硫排放量远大于实际排放量.在此基础上,提出石油加工业二氧化硫产排污系数修订建议.  相似文献   
134.
固体发动机药柱应力应变仿真与试验验证研究   总被引:2,自引:2,他引:0  
目的研究某导弹固体发动机药柱在不同环境温度下的性能演变规律。方法利用ABAQUS有限元分析软件,仿真计算了药柱在-40,20,50℃下的应力应变情况,在此基础上通过推进剂拉伸应力松弛试验对仿真结果进行验证分析。结果最大应力应变发生在头部人工脱粘层的根部,药柱内部沿径向越靠近内孔表面,应力应变的数值越大,沿药柱的轴向,内孔表面的最大应力应变发生在靠近药柱中间位置。结论线粘弹性本构关系模型在较低应变水平下可以很好地模拟出推进剂的力学行为,当应变水平在14.3%以下时,试验和仿真的相对误差能控制在10%以内。  相似文献   
135.
Since its inception, the STPA technique has gained increasing popularity among researchers and industry practitioners. Nevertheless, the validity of its application has not yet received much scientific attention. Although some informal validation approaches have been used by STPA users, no formalized validation framework has been elaborated for practical use. This paper investigates the reasonableness of the recently proposed STPA validation framework, which includes 15 validation tests, each focusing on a specific step of an STPA analysis. To do so, STPA experts in both academia and industry were interviewed. First, it is investigated what approaches they have been using for validating an STPA analysis, the findings of which were categorized and mapped with the proposed validation framework. This aims to investigate the similarities and dissimilarities between the theory-based validation framework and the informal methods applied by experts in current practice. Then, the proposed framework was presented to the interviewees to seek their judgments about its reasonableness. Feedback from practitioners indicated that the proposed STPA validation framework has certain strengths, while several opportunities exist for further improvement. In particular, the findings indicate that most of the proposed theory-based tests have been already used by STPA experts in an unstructured manner. The experts appreciated the framework in that it provides clear guidance on how to validate each step of an STPA analysis systematically, and found some additional theory-based tests interesting for consideration in practice. The results also suggest that further research is needed to develop systematic techniques for performing each test to facilitate its application by STPA experts.  相似文献   
136.
A method for determining atmospheric concentrations of eight pesticides applied to corn and soybean crops in Mato Grosso state, Brazil is presented. The method involved a XAD-2 resin cartridge coupled to a low volume air pump at 2 L min?1 over 8 hours. Pesticides were recovered from the resin using sonication with n-hexane:ethyl acetate and determined by GC-MS. Good accuracy (76–128%) and precision (CV < 20%) were obtained for atrazine, chlorpyrifos, alpha- and beta-endosulfan, endosulfan sulfate, flutriafol, malathion, metolachlor and permethrin. Method detection ranged from 9.0 to 17.9 ng m?3. This method was applied to 61 gas phase samples collected between December 2008 and June 2009. Atrazine and endosulfan were detected both in urban and rural areas indicating the importance of atmospheric dispersion of pesticides in tropical areas. The simple and efficient extraction method and sampling system employed was considered suitable for identifying pesticides in areas of intense agricultural production.  相似文献   
137.
不确定背景环境下车道检测技术的研究   总被引:1,自引:0,他引:1  
针对不确定背景的交通环境,提出一种新的车道检测算法。确定道路路面的色彩范围,提取车道标线的色彩信息,消除光照强度变化对车道标线信息提取过程的影响;通过对比车辆与车道标线在大小、形状和运动模式3方面的差异排除车道中车辆对车道线检测的干扰;单帧图像的车道检测结果存储于车道一致性确认模块中,运用车道标志线一致性确认提高车道检测结果的准确性。试验结果表明,该方法能够有效地检测各种天气条件下车道区域以及解决车道遮挡问题。  相似文献   
138.
安全仪表系统的开发与要求   总被引:1,自引:1,他引:0  
综述安全仪表系统的发展过程;对其主要组成、特点以及其各自要求进行研讨;给出安全仪表系统开发的简化流程;探讨安全仪表系统的经济性分析和仪表选择方法;对安全仪表系统整体生命周期中的计划编制、设计、实施、运行、维护和确认等各阶段活动的关键要求进行了讨论和研究。该研究对安全仪表系统的深入理解有指导作用,并为安全仪表系统的分析、设计、实施、运行和维护等活动提供参考。  相似文献   
139.
以《固体废物痕量金属元素的测定电感耦合等离子体发射光谱法》编制说明(征求意见稿)中精密度数据为例,方法标准编制单位在处理方法验证数据时,应按照《GB/T 6379.2—2004》离群值剔除方法处理异常数据,避免重复性限r和再现性限R计算错误。  相似文献   
140.
The work was carried out to develop and validate a method based on liquid chromatography tandem mass spectrometry (LC-MS/MS) for the simultaneous detection and quantification of five neonicotinoid insecticides: acetamiprid, clothianidin, imidacloprid, thiacloprid and thiamethoxam in groundwater samples for the purpose of a further column experiment. This experiment will be used to analyze breakthrough curves of neonicotinoids under a saturated water flow to set transport parameters, where the reliability of the results of chemical analysis plays an important role. The validation was performed in a concentration range from 0.09?µg L?1 to 100?µg L?1 using an Infinity 1290 (Agilent, USA) chromatograph coupled with a QTrap 5500 mass spectrometer (Sciex, Canada). The calibration curves were obtained on the basis of the results of six standard solution analyses. Linearity was not lower than 0.998. The limit of detection was set at the lowest concentration which can be determined with an acceptable accuracy and precision. All pesticides had recoveries in the range 85–109% with relative standard deviation values less than 8.1%. The estimated measurement uncertainty did not exceed 30%, so the LC-MS/MS method fits for the intended purpose.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号