In this paper, the assessment and modelling of alternative renewable energy systems for Masirah Island is considered. The hybrid system that is simulated comprises various combinations of wind turbines and/or photovoltaic (PV) supplemented with diesel generators and short-term battery storage. It was found from the analysis that the PV–wind–diesel hybrid system, with battery unit, has the lowest cost values as compared to solar-only or wind–diesel hybrid systems. Furthermore, the study illustrates that for a given hybrid system the presence of battery storage will reduce diesel consumption. The decrease in carbon emission, the percentage of fuel savings, the cost of energy production and the effect of wind and PV penetration are also addressed in this paper. The PV–wind–diesel hybrid option is techno-economically viable for the electrification of the Masirah Island. 相似文献
ABSTRACTThis work deals with the optimization of an hybrid energy system used to supply an isolated site. The proposed system combines a wind turbine, a photovoltaic panel, a diesel generator and a battery bank to electrify atypical home. An energy cost-effectiveness approach is adopted in accordance with meteorological data, time profile of energy consumption, and the cost of different alternative systems. A variety of performances is obtained through simulations within the Homer Pro environment. The selection of an optimal combination is based on the maximum integration of renewable energy in the suggested system with a minimum of gas emission. According to the obtained results, the overall cost of the selected installation is about 72,900 €, with 0.415€ the unit cost of a kWh electric energy provided with a contribution of renewable energy of around 86%. Simulations show a technical and financial benefits of the different configurations obtained to supply the target site. To control the proposed hybrid energy system, a supervision algorithm is developed and implemented on TMS320F28027 DSP platform. The proposed energy system aims to take advantages of renewable energy sources and shift to conventional sources only when necessary in order to ensure source autonomy and service continuity. 相似文献
This paper presents an aerosol generation technique developed to produce dry aerosol particles of various sizes from aqueous solutions of salt. The technique was tested with sodium chloride, lithium carbonate and uranyl acetate at various aqueous concentrations which produced particles in the size range of 0.13-1.37 microm Mass Median Diameter (MMD). The generated aerosols were acceptably monodisperse with a geometric standard deviation of 1.4-2. Both MMD and Mass Median Aerodynamic Diameter (MMAD) increased significantly (p<0.001) with increased concentration of the salt in solution. The technique can also be used to generate aerosols of different chemical species. The results obtained indicate that the system is convenient for use with various aerosol-forming materials, with a stable particle size distribution being maintained for a long period of steady operation. The technique was successfully applied in wind tunnel studies to simulate the release of submicron radioactive particles and their interception by crops, grass and tree canopies. The relevance and application of the technique in other areas of environmental assessment studies is discussed. 相似文献
ABSTRACT: A simple simulator was constructed, calibrated, programmed and used in management studies of a hydraulic system containing two pumping stations in series, connected by canals and reservoirs. The features of the model, its calibration and use are described, and comparisons between measured and computed hydraulic behavior are presented. 相似文献
The paper reviews large scale experiments with various fuels in air where successful deflagration to detonation transition (DDT) took place. This includes a recent experiment disclosed in the Buncefield R&D program, where DDT developed in the propane/air mixture. The DDT occurred in branches of deciduous trees in a premixed stagnant mixture. An internal R&D investigation programme was initiated to better understand the phenomena. A large scale experiment in an open space with ethane air mixture is presented in the paper. The premixed mixture was ignited at the edge of the congested three-dimensional rigs which consisted of vertical and horizontal pipes. After ignition, the flame accelerated in the congestion and transitioned to detonation at the end of congestion. Stable detonation propagated through the remaining open and uncongested space.The flame acceleration process leading to DDT is scale dependent. It also depends on many parameters leading to a large investigation array and, significant cost. However, such R&D efforts aimed toward a safer plant design, i.e. the prevention of occurrence of a major accident, are a small fraction of a real accident cost. 相似文献
Solar energy application in a large spectrum has the potential for high-efficiency energy conversion. Though, solar cells can only absorb photon energy of the solar spectrum near their band-gap energy, and the remaining energy will be converted into thermal energy. The use of the thermoelectric generator becomes a necessity for convert this thermal energy dissipated so as to increase efficiency conversion.
This paper analyses the feasibility of photovoltaic-thermoelectric hybrid system and reviews their performance in order to optimize harvested energy. Regarding the thermoelectric effect, a new method of the ambient energy harvesting is presented. This method combines thermoelectric generators and the effects of heat sensitive materials associated to photovoltaic cells in phase change for generating both energy day and night. Experimental measures have been conducted primarily in laboratory conditions for a greater understanding of hybridization phenomena under real conditions and to test the actual performance of devices made. Results show that the hybrid system can generate more power than the simple PV and TEG in environmental conditions. This hybrid technology will highlight the use of renewable energies in the service of the energy production. 相似文献