Constructed wetland (CW) is the preferred means of controlling water quality because of its natural treatment mechanisms and
function as a secondary or tertiary treatment unit. CW is increasingly applied in Korea for secondary e uent of livestock wastewater
treatment. This study was conducted to recognize the characteristics of contaminants in the accumulated sediment at the bottom soil
layer and to reduce the phosphorus release from sediments of the free water surface CW for the treatment of secondary piggery
wastewater e uent from a livestock wastewater treatment facility. The results revealed that the dominant phosphorus existence types
at near the inlet of the CW were non-apatite phosphorus (59%) and residual phosphorus (32%) suggesting that most of the particles of
the influent are made up of inorganic materials and dead cells. Sediment accumulation is important when determining the long-term
maintenance requirements over the lifetime of CW. Continuous monitoring will be performed for a further assessment of the CW
system and design. 相似文献
Objectives: In this article, we evaluate the sensitivity to cognitive load of 3 versions of the Detection Response Task method (DRT), proposed in ISO Draft Standard DIS-17488.
Methods: We present a user study with 30 participants in which we compared the sensitivity to cognitive load of visual, audio, and tactile DRT in a simulated driving environment. The amount of cognitive load was manipulated with secondary n-back tasks at 2 levels of difficulty (0-back and 1-back). We also explored whether the DRT method is least sensitive to cognitive load when the stimuli and secondary task are of the same modality. For this purpose, we used 3 forms to present the n-back task stimuli: visual, audio, and tactile. Responses to the task were always vocal. The experiment was based on a between-subject design (the DRT modalities) with 2 levels of within-subject design study (modalities and difficulty of the secondary n-back tasks). The participants' primary task in the study was to drive safely, and a second priority was to answer to DRT stimuli and perform secondary tasks.
Results: The results indicate that all 3 versions of the DRT tested were sensitive to detecting the difference in cognitive load between the reference driving period and driving and engaging in the secondary tasks. Only the visual DRT discriminated between the 0-back and 1-back conditions on mean response time. Contrary to expectations, no interaction was observed between DRT modality and the stimuli modality used for presentation of the secondary tasks.
Conclusions: None of the 3 methods of presenting DRT stimuli showed a consistent advantage in sensitivity in differentiating multiple levels of cognitive load if all response times, hit rates, and secondary task performance are considered. If only response time is considered, the visual presentation of the DRT stimulus used in this study showed some advantages. In interpreting these data, it should be noted that the methods of DRT stimulus presentation varied somewhat from the currently proposed draft ISO standard and it is possible that the relative salience level of the visual DRT stimulus influenced the findings. It is further suggested that more than 2 levels of difficulty of the n-back task should be considered for further investigation of the relative sensitivity of different DRT stimuli modalities. Parameters that indicate change in cognitive load (response time, hit rate, task performance) should be analyzed together in assessing the overall impact on the driver and not individually, in order to obtain a fuller insight of the assessed cognitive load. 相似文献
采用ClO_2三相催化氧化工艺对焦化污水二沉池出水的处理进行了中试研究,考察了进水量、供气量、加药量等参数对焦化污水COD处理效果的影响,得出的最佳工艺条件为:进水量0.2 m~3/h,有效催化剂用量0.5 m~3,供气量10 m~3/h,盐酸投加量60 m L/h,氯酸钠投加量30 m L/h。最佳工艺条件下,平均出水COD为44 mg/L,平均去除率为80.3%,能达到国家一级排放标准。 相似文献
The aim of this study is to investigate the denitrification potential enhancement by addition of external carbon sources and to estimate the denitrification potential for the predenitrification system using nitrate utilization rate (NUR) batch tests. It is shown that the denitrification potential can be substantially increased with the addition of three external carbon sources, i.e. methanol, ethanol, and acetate, and the denitrification rates of ethanol, acetate, and methanol reached up to 9.6, 12, and 3.2 mgN/(g VSS.h), respectively, while that of starch wastewater was only 0.74 mgN/(g VSS,h). By comparison, ethanol was found to be the best external carbon source. NUR batch tests with starch wastewater and waste ethanol were carried out. The denitfification potential increased from 5.6 to 16.5 mg NO3-N/L owing to waste ethanol addition. By means of NUR tests, the wastewater characteristics and kinetic parameters can be estimated, which are used to determine the denitrification potential of wastewater, to calculate the denitrification potential of the plant and to predict the nitrate effluent quality, as well as provide information for developing carbon dosage control strategy. 相似文献