全文获取类型
收费全文 | 78篇 |
免费 | 3篇 |
国内免费 | 5篇 |
专业分类
安全科学 | 1篇 |
废物处理 | 9篇 |
环保管理 | 1篇 |
综合类 | 16篇 |
基础理论 | 10篇 |
污染及防治 | 37篇 |
评价与监测 | 10篇 |
社会与环境 | 2篇 |
出版年
2021年 | 1篇 |
2020年 | 3篇 |
2019年 | 1篇 |
2018年 | 1篇 |
2017年 | 2篇 |
2016年 | 1篇 |
2014年 | 2篇 |
2013年 | 9篇 |
2012年 | 5篇 |
2011年 | 9篇 |
2010年 | 2篇 |
2009年 | 4篇 |
2008年 | 3篇 |
2007年 | 5篇 |
2006年 | 10篇 |
2005年 | 2篇 |
2004年 | 2篇 |
2003年 | 2篇 |
2002年 | 10篇 |
2001年 | 5篇 |
2000年 | 1篇 |
1998年 | 3篇 |
1996年 | 2篇 |
1995年 | 1篇 |
排序方式: 共有86条查询结果,搜索用时 62 毫秒
11.
Chun Wai Lee Dennis G. Tabor Kenneth A. Cowen 《Journal of Material Cycles and Waste Management》2008,10(1):38-45
The performance of four dioxin emission monitors, including two long-term sampling devices, the Dioxin-MonitoringSystem (DMS)
and AMESA (the adsorption method for sampling dioxins and furans), and two semireal-time continuous monitors, the resonance
ionization with multimirror photon accumulation time-of-flight mass spectrometer (RIMMPA-TOFMS) and the jet resonance-enhanced
multiphoton ionization (jet-REMPI) system were tested. A package boiler burning a simulated chlorinated hazardous waste was
used for a total of nine tests. Reference samples were collected during each test and analyzed for polychlorinated dibenzodioxins
and dibenzofurans (PCDDs/Fs) using gas chromatography mass spectrometry. The PCDD/F concentrations of the reference samples
measured by EPA Method 23 ranged from 0.9 to 6.0 ng toxic equivalence (TEQ)/dry standard cubic meter. The relative accuracies
achieved by DMS, AMESA, and jet-REMPI varied from 22.6% to 78.2%, with 100% data completeness. The RIMMPA-TOFMS produced no
quantifiable results due to various difficulties associated with the instrument during the testing. The two long-term samplers
were easy to install and operate and provided a cumulative, averaged emission for the sampling period. The operations of the
two semi-real-time continuous monitors were relatively complex, but one of them provided on-site, real-time data for PCDD/F
emissions from measurement of a TEQ correlative indicator compound. This article summarizes results from the individual Environmental
Technology Verification reports for the four dioxin monitors.
This work was presented, in part, at the Fourth International Conference on Combustion, Incineration/Pyrolysis and Emission
Control (i-CIPEC) 相似文献
12.
生活垃圾焚烧发电厂周边环境二噁英污染水平及人群暴露评估 总被引:1,自引:0,他引:1
选取某典型生活垃圾焚烧发电厂为研究对象,监测其周边环境空气、土壤、地下水、农作物等环境介质中二噁英的浓度水平,初步评估周边人群二噁英暴露水平。研究结果表明,该厂周边环境空气、土壤、地下水中二噁英测定值分别为0. 236 pg TEQ/m3~0. 331 pg TEQ/m3、1. 94 ng TEQ/kg~2. 71 ng TEQ/kg、0. 17 pg TEQ/L~0. 26 pg TEQ/L,企业排放的二噁英对周边环境影响较小;成人和儿童在暴露介质中摄入二噁英总量分别为0. 959 pg TEQ/(kg·d)和1. 59 pg TEQ/(kg·d),均低于4 pg TEQ/(kg·d)的标准,经大米和面粉摄入二噁英的量超过总暴露量的90%,提示食物是人群二噁英暴露的主要介质。 相似文献
13.
14.
15.
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are formed during waste incineration and in waste-to-energy boilers. Incomplete combustion, too short residence times at low combustion temperatures (<700 °C), incineration of electronic waste and plastic waste containing chlorine are all factors influencing the formation of PCDD/Fs in boilers. The impact of chlorine and catalysing metals (such as copper and iron) in the fuel on PCDD/F formation was studied in a 12 MWth circulating fluidised bed (CFB) boiler. The PCDD/F concentrations in the raw gas after the convection pass of the boiler and in the fly ashes were compared. The fuel types were a so-called clean biomass with low content of chlorine, biomass with enhanced content of chlorine from supply of PVC, and solid recovered fuel (SRF) which is a waste fuel containing higher concentrations of both chlorine, and catalysing metals. The PCDD/F formation increased for the biomass with enhanced chlorine content and it was significantly reduced in the raw gas as well as in the fly ashes by injection of ammonium sulphate. A link, the alkali chloride track, is demonstrated between the level of alkali chlorides in the gas phase, the chlorine content in the deposits in the convection pass and finally the PCDD/F formation. The formation of PCDD/Fs was also significantly reduced during co-combustion of SRF with municipal sewage sludge (MSS) compared to when SRF was fired without MSS as additional fuel. 相似文献
16.
Levels of PCDD/Fs were measured at four different sites in Zagreb, capital of Croatia. Also one sample was taken during spontaneously initiated open fire on a landfill and one sample where garden waste of unknown content was burnt. Over period 1997–2000, 28 samples were collected and levels ranged between 9 and 306 fg I-TEQ m−3, except in the sample collected during landfill fire. Air PCDD/F levels in Zagreb at four sites were different and the highest levels were observed in industrial area. Seasonal variation of levels is also evident with higher levels in winter than in summer. Our results show that PCDD/F levels in ambient air collected in Zagreb are at lower end of the published data range. In general, homologue profiles were quite similar for all locations, the concentration of PCDD homologues increased while the concentration of PCDF homologues decreased with increasing degree of chlorination. PCDD/F levels in the landfill fire sample was 13 200 fg I-TEQ m−3 which are much higher than levels in garden waste burning sample or in sample collected at industrial site. During landfill fire, the concentration of 2,3,7,8-TCDF becomes even higher than the concentration of OCDF and is equal to the concentration of 1,2,3,4,6,7,8-HpCDF. 相似文献
17.
国内外二恶英研究初探 总被引:5,自引:0,他引:5
总结了国际上近年来环境中二恶英的研究成果及进展概况。主要分挤二恶英的毒性及来源,综合国内外有关二恶英的绝大部分研究成果,并简要提出二恶英的防治措施。 相似文献
18.
以三种树叶焚烧测定结果为例,分析了植物燃烧过程中产生的二类。研究结果表明,不同植物焚烧排放的二类浓度不同,含氯高时排放二类浓度也较高。二类对生态环境和人类健康有巨大的危害,分析二类污染物的农业面源情况,对于进一步有效控制和降低二类的排放,有重要的现实意义。 相似文献
19.
K. Nakamiya T. Furuichi K. Ishii 《Journal of Material Cycles and Waste Management》2003,5(1):0063-0068
The optimal soil-washing conditions for dioxins were estimated on a soil sample from the circumference of an incinerator
in Nose City, Osaka, Japan. The solvents ethanol, methanol, and acetone, together with a surfactant (100% of each) could extract
40% of the dioxins from contaminated soil at room temperature. From among these solvents, ethanol was chosen for a study on
how to optimize the extraction conditions because of its low toxicity and its economic advantages. The time-course of the
agitation showed that the extraction rate increased for 1 min, and thereafter the rate decreased. Therefore, the agitation
time was fixed at 1 min. To estimate the effect of temperature on the extraction rate, the extraction temperature was changed.
The amount of dioxins extracted was largest at the boiling point of ethanol (78.3°C), giving about 76% extraction. Furthermore,
at this temperature, almost 100% of the dioxins in the contaminated soil were extracted when the ratio of water to ethanol
was 20%.
Received: March 6, 2002 / Accepted: September 9, 2002 相似文献
20.
Pietro Tundo Stefano Raccanelli Laila A. Reda Mohamed Tawic Ahmed 《Chemistry and Ecology》2004,20(4):257-265
Lake Temsah is one of the main wetlands in the Suez Canal region, and the main source for fish for the area. The lake is the end-point of several wastewater effluents. In the present study, residues of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs), dioxin-like polychlorinated biphenyl (PCB) and polycyclic aromatic hydrocarbons (PAH) were monitored in the sediment of the lake. Samples were collected from six different sampling stations around the lake using a box-corer sampler, then kept frozen. Samples were extracted and cleaned up before residue determination was conducted using an HRGC/HRMS. An HP 6890 plus gas chromatograph was coupled to a Micromass Autospec Ultima mass spectrometer operating in EI mode at 35 eV and with a resolution of 10.000 (5% valley). PCDDs and PCDFs were detected in all sediment samples collected from various sampling stations. Results showed some progressive increase in PCDDs concentrations relevant to increase in chlorination. In the PCDD group of congeners, 1, 2, 3, 4, 6, 7, 8, 9 octa-CDD had the highest detected concentrations in all samples, while 2, 3, 7, 8 tetra-CDD showed the lowest concentrations. The World Health Organization toxicity equivalents ranged from 0.387 to 11.20 ng kg-1 d.w. For PCDD homologues, hexa-CDD was the most dominant homologue in all sediment samples analysed. Regarding dioxin-like PCBs, results showed that IUPAC No. 118 congener, 2, 3, 4, 4, 5, pentachlorobiphenyl was the most concentrated of all detected congeners, with concentrations ranging between 0.039 and 43.201 µg kg-1. For polycyclic aromatic hydrocarbons, benzo(b+k+j)fluoranthene had the highest concentrations in almost all sampling stations. However, fluorene was the smallest detected concentration in almost all stations. This result would indicate that PAH contamination of the lake seems to be coming from one main source in all sampling stations. The present work is the first record of PCCDs, PCCFs, and dioxin-like PCBs in the Temsah lake. The concentrations of the contaminants monitored in this study, especially those of PAHs, are rather alarming. Efforts should be made to stop point sources that contaminate the lake. 相似文献