首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   30篇
  免费   0篇
  国内免费   2篇
安全科学   1篇
废物处理   6篇
环保管理   2篇
综合类   14篇
污染及防治   6篇
评价与监测   2篇
社会与环境   1篇
  2017年   1篇
  2014年   1篇
  2013年   4篇
  2012年   1篇
  2011年   2篇
  2010年   1篇
  2009年   2篇
  2008年   1篇
  2007年   2篇
  2006年   1篇
  2005年   2篇
  2004年   2篇
  2003年   3篇
  2002年   1篇
  2001年   3篇
  2000年   1篇
  1999年   2篇
  1998年   1篇
  1995年   1篇
排序方式: 共有32条查询结果,搜索用时 18 毫秒
11.
Chang MB  Chi KH  Chang-Chien GP 《Chemosphere》2004,55(11):1457-1467
Partitioning of PCDD/F congeners between gaseous and particulate phases and removal efficiencies of the air pollution control devices (APCDs) for PCDD/Fs at an existing municipal waste incinerator (MWI) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP), wet scrubbers (WS) and selective catalytic reduction system (SCR) as APCDs. The average PCDD/F concentration of stack gas is 1.49 ng/N m3, and the International Toxic Equivalent Quantity (I-TEQ) is 0.043 ng-I-TEQ/N m3. The EP increases PCDD/F concentration by 174.0% while the average removal efficiency of WS + SCR system for PCDD/Fs reaches 99.1%. In addition, the PCDF removal efficiency achieved with WS + SCR system (97.1–99.8%) is higher than that for PCDDs (96.5–99.3%). The results obtained on gas/particulate partitioning in flue gas indicate that the particulate-phase PCDD/Fs accounted for 65% at the inlet of EP, 20% at the outlet of EP and 50% at the stack, respectively, of the total PCDD/F concentrations. This study also indicates that as the chlorination level of PCDD/F congeners increases, the percentage of PCDD/Fs existing in gas phase decreases in all flue gas samples.  相似文献   
12.
主要介绍了齐齐哈尔医疗废物焚烧装置的运行及管理;针对焚烧装置的运行要求阐述了焚烧装置运行操作的注意事项及必要的管理措施。  相似文献   
13.
Thiobacillus ferrooxidans to leach metals from APCR to render them nonhazardous. The multistage solubilization process involves an alkaline aqueous phase that removes some Pb. In the second phase, the APCR are acidified to pH 4 with H2SO4, then inoculated with a bacterial culture that has been acclimated in the presence of 2% Fe (FeCl3). Several rinses and decantings achieve removal of the leachable metals. The final step involves the addition of Ca(H2PO4)2 and an increase in the treatment pH prior to the final filtration. Viability of thiobacilli in APCR was poor. Despite this problem, the removal of Pb was 35.9%, 46.0%, and 68.7% (for APCR containing 1594, 3026, and 5038 mg Pb/kg, respectively), which demonstrates greater metal removal with increased APCR contamination. Zn removal varied from 68.2% (8273 mg Zn/kg APCR) to 79.5% (16,873 mg Zn/kg APCR), which was positively correlated to the level of residue contamination, whereas Cu was removed in the proportions of 26.9% (495 mg Cu/kg APCR) to 68.2% (465 mg Cu/kg APCR). Cadmium removal appeared to be independent of the level of Cd in the APCR; Cd was removed to the greatest degree, with a variation of 92.0% (129 mg Cd/kg APCR) to 94.7% (267 mg Cd/kg APCR). The treated APCR were tested using four different leachate tests. The APCR released 43 mg Pb/liter during contact with water, and 7.40 mg Cd/liter during TCLP [the toxicity characterization leaching procedure of the United States Environmental Protection Agency (US EPA)]. After biological treatment, the leachate from TCLP was within the acceptance criteria of the US EPA, if the pH of the APCR was increased to pH 5 after the biological treatment. In the case of the Transport Canada leaching test, a betterment of the process is required in order to satisfy the stringent regulatory level of 0.5 mg Cd/liter (0.68 and 0.57 mg/liter).  相似文献   
14.
In a bulk chemical plant producing resins, a flashback from an incinerator through the vent system into the reactor hall occurred during commissioning of a newly installed vent header system. The original design of the vent header system was seriously flawed not being in line with current practice. Subsequently the vent header was re-designed into a rich/lean vent header system. This paper explores the reasons behind a number of incidents and near misses that occurred during both the commissioning of a vent header system and its recommissioning following system re-design. Furthermore, it reflects on some broader implications for approaches to safety around what can be recognised as complex socio-technical systems.  相似文献   
15.
介绍二噁的毒性及其在环境中的存在状态,并就在垃圾焚烧中如何控制二噁(口英)的产生及焚烧后残渣、飞灰的处理进行了探讨。  相似文献   
16.
医疗垃圾与医疗垃圾的处理   总被引:3,自引:0,他引:3  
本文论述了医疗垃圾的特性及处理方法,联系国外对医疗垃圾的管理及处理方法的发展,对我国医疗垃圾的管理及处理现状加以分析.  相似文献   
17.
Management of natural aggregate resources has become one of the most important challenges in construction, especially for high demand applications such as roads. Incinerator bottom ash (IBA), which is produced from burning domestic waste, has been considered a useful solution to the shortage of natural resources. In this research, IBA was mixed with limestone to produce an acceptable blend for use as a road foundation layer. Novel and traditional additives were adopted to improve the mechanical properties of IBA blends. The study focused on the treatment effect of additives on the mechanical characteristics of IBA blends under monotonic and cyclic triaxial stresses. The investigation evaluated fundamental material properties, including resilient modulus, initial Young's modulus and Poisson's ratio. Two nonlinear empirical models were adopted to depict the experimental resilient modulus results of the IBA blends. An approach has been proposed to predict realistic and representative values of resilient modulus for the material. In addition, a new relationship has been established between Young's modulus, resilient modulus and Poisson's ratio. Triaxial test results revealed that additives are more efficient with the control limestone blend than with the IBA blends. Novel additives, such as enzyme I and silica fume, produced a noticeable improvement in IBA properties in comparison to traditional additives.  相似文献   
18.
The stack gases of a municipal solid waste incinerator (MSWI), and ambient air were sampled in four locations around the plant for the analysis of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs). The sampling area was close to an industrial area near Trieste, in north-east Italy. The purpose of the study was to estimate the impact of the MSWI emissions and to distinguish the contribution of these emissions from other potential emission sources in the industrial area.PCDD/F atmospheric concentrations were similar to those generally detected in urban–rural areas with one location about 2–3 times more contaminated than the others. Since the most contaminated location was inside the industrial area but upwind of the MSWI, principal component analysis (PCA) was used to establish whether other sources were the cause. This analysis clearly showed that a local steel plant’s emission was the main source of PCDDs/Fs in ambient air. This study highlights the usefulness of multivariate data analysis such as PCA to identify, among different potential emission sources, the one really responsible for the contamination.  相似文献   
19.
A new iron oxide catalyst, which has a superior oxidation activity in carbon monoxide and polyethylene (PE) combustion, was synthesized by an aqueous solution reaction. Catalytic oxidation of carbon monoxide over six kinds of hematite obtained from the goethite was done using a microcatalytic pulse reactor, and the composition of the hematite with the highest oxidation activity was determined. With the aim of suppressing dioxin formation on combustion, incineration tests of solid wastes in PE refuse bags with and without the goethite were carried out using a commercial semibatch-type incinerator with a combustion chamber of 6.2 m3. The result confirmed that the concentration of dioxins in the flue gas decreased considerably when the refuse was incinerated in PE bags manufactured with goethite. Received: July 24, 2000 / Accepted: October 18, 2000  相似文献   
20.
The use of sophisticated air pollution modeling systems to evaluate the impact of different industrial plant emissions is currently done in an extensive way. MM5-CMAQ (PSU/NCAR and EPA, USA) is one of the most applicable air quality modeling systems to evaluate those impacts. In this contribution we present the methodology and results obtained when applying the MM5-CMAQ air quality modeling system for evaluating the potential impact of an incinerator in San Sebastián (Basque Country, Spain). We have used the EMIMO (UPM, Spain) emission model to simulate the emissions from biogenic and anthropogenic sources including traffic and tertiary sector sources. The study includes the air quality impact of a highway located near the incinerator named A8 and 6 industrial plants which already exist. The impact study has been compared with the results obtained from this highway impact and the 6 industrial plants which are normally operating during the last 30 years. The system has been prepared to simulate also Cadmium, Arsenic, Nickel, Lead and Benzo(a)pyrene air quality impacts. The PCDD/F air concentrations have been determined for the 16 toxic dioxins and furans as determined in the bibliography. The criteria pollutants such as CO, NOx, SO(2), PM(10) and O(3) have also been determined according to the different EU Directives which limit the values of such a pollutants for different periods of time.  相似文献   