A bioretention unit (BRU) or cell is a green infrastructure practice that is widely used as a low impact development (LID) technique for urban stormwater management. Bioretention is considered a good fit for use in China’s sponge city construction projects. However, studies on bioretention design, which incorporates site-specific environmental and social-economic conditions in China are still very much needed. In this study, an experimental BRU, consisted of two cells planted with Turf grass and Buxus sinica,was tested with eighteen synthesized storm events. Three levels (high, median, low) of flows and concentrations of pollutants (TN, TP and COD) were fed to the BRU and the performance of which was examined. The results showed that the BRU not only delayed and lowered the peak flows but also removed TN, TP and COD in various ways and to different extents. Under the high, medium and low inflow rate conditions, the outflow peaks were delayed for at least 13 minutes and lowered at least 52%. The two cells stored a maximum of 231 mm and 265 mm for turf grass and Buxus sinica, respectively. For both cells the total depth available for storage was 1,220 mm, including a maximum 110 mm deep ponding area. The largest infiltrate rate was 206 mm/h for both cells with different plants. For the eighteen events, TP and COD were removed at least 60% and 42% by mean concentration, and 65% and 49% by total load, respectively. In the reservoir layer, the efficiency ratio of removal of TN, TP and COD were 52%, 8% and 38%, respectively, within 5 days after runoff events stopped. Furthermore, the engineering implication of the hydrological and water quality performances in sponge city construction projects is discussed.
An uptake parameter u (L kg−1 d−1) and a loss rate parameter k (d−1) were estimated for the patterns of accumulation and loss of 133Cs by three fish species following an experimental 133Cs addition into a pond in South Carolina, USA. These u and k parameters were compared to similar estimates for fish from other experimental ponds and from lakes that received 137Cs deposition from Chernobyl. Estimates of u from ponds and lakes declined with increasing potassium concentrations in the water column. Although loss rates were greater in the experimental ponds, the times required to reach maximum Cs concentrations in fish were similar between ponds and lakes, because ponds and lakes had similar retentions of Cs in the water column. The maximum Cs concentrations in fish were largely determined by initial Cs concentrations in the water column. These maximum concentrations in fish and the times required to reach these maxima are potentially useful indicators for assessments of risks to humans from fish consumption. 相似文献
The objective of this study is to investigate the air ventilation impacts of the so called “wall effect” caused by the alignment of high-rise buildings in complex building clusters. The research method employs the numerical algorithm of computational fluid dynamics (CFD – FLUENT) to simulate the steady-state wind field in a typical Hong Kong urban setting and investigate pollutant dispersion inside the street canyon utilizing a pollutant transport model. The model settings of validation study were accomplished by comparing the simulation wind field around a single building block to wind tunnel data. The results revealed that our model simulation is fairly close to the wind tunnel measurements. In this paper, a typical dense building distribution in Hong Kong with 2 incident wind directions (0° and 22.5°) is studied. Two performance indicators are used to quantify the air ventilation impacts, namely the velocity ratio (VR) and the retention time (Tr) of pollutants at the street level. The results indicated that the velocity ratio at 2 m above ground was reduced 40% and retention time of pollutants increased 80% inside the street canyon when high-rise buildings with 4 times height of the street canyon were aligned as a “wall” upstream. While this reduction of air ventilation was anticipated, the magnitude is significant and this result clearly has important implications for building and urban planning. 相似文献
Anaerobic ammonium oxidation (ANAMMOX) technology has potential technical superiority and economical efficiency for the nitrogen removal from landfill leachate, which contains high-strength ammonium nitrogen (NH4 -N) and refractory organics. To complete the ANAMMOX process, a preceding partial nitritation step to produce the appropriate ratio of nitrite/ammonium is a key stage. The objective of this study was to determine the optimal conditions to acquire constant partial nitritation for landfill leachate treatment, and a bench scale fixed bed bio-film reactor was used in this study to investigate the effects of the running factors on the partial nitritation. The results showed that both the dissolved oxygen (DO) concentration and the ammonium volumetric loading rate (Nv) had effects on the partial nitritation. In the controlling conditions with a temperature of 30±1℃, Nv of 0.2-1.0 kg NH4 -N/(m3d), and DO concentration of 0.8-2.3 mg/L, the steady partial nitritation was achieved as follows: more than 94% partial nitritation efficiency (nitrite as the main product), 60%-74% NH4 -N removal efficiency, and NO2--N/NH4 -N ratio (concentration ratio) of 1.0-1.4 in the effluent. The impact of temperature was related to iVv at certain DO concentration, and the temperature range of 25-30癈 was suitable for treating high strength ammonium leachate. Ammonium-oxidizing bacteria could be acclimated to higher FA (free ammonium) in the range of 122-224 mg/L. According to the denaturing gradient gel electrophoresis analysis result of the bio-film in the reactor, there were 25 kinds of 16S rRNA gene fragments, which indicated that abundant microbial communities existed in the bio-film, although high concentrations of ammonium and FA may inhibit the growth of the nitrite-oxidizing bacteria and other microorganisms in the reactor. 相似文献
Ion mobility spectrometry (IMS) is a very fast, highly sensitive, and inexpensive technique, it permits efficient monitoring of volatile organic compounds like alcohols. In this article, positive ion mobility spectra for six alcohol organic compounds have been systematically studied for the first time using a high-resolution IMS apparatus equipped with a discharge ionization source. Utilizing protonated water cluster ions (H2O)nH^+ as the reactant ions and clean air as the drift gas, alcohol organic compounds, ethanol, 1- propanol, 2-propanol, 1-butanol, 1-pentanol and 2-octanol, all exhibit product ion characteristic peaks in their respective ion mobility spectrometry, that is a result of proton transfer reactions between the alcohols and reaction ions (H2O)nH^+. The mixture of these alcohols, including two isomers, has been detected, and the results showed that they could be distinguished effectively in the ion mobility spectrum. The reduced mobility values have been determined, which are in very well agreement with the traditional ^63Ni-IMS experimental values. The exponential dilution method was used to calibrate the alcohol concentrations, and a detection limit available for the alcohols is in order of magnitude of a few ng/L. 相似文献