In order to investigate the role of the microbial community in aquatic ecology and nutrient transformations in the development of eutrophication in large shallow freshwater lakes along Yangtze River, the microbial community in the depth-related sediment in Lake Chaohu and Lake Longganhu were compared. Lake Chaohu is one of the three most polluted lakes in China. However, the neighboring Lake Longganhu, a mesotrophic lake, is relatively pristine. The total phosphorous (TP) and total nitrogen (TN) concentration in water was detected at 0.193 mgl(-1) and 3.035 mgl(-1) for Lake Chaohu, 0.051 mgl(-1) and 0.774 mgl(-1) for Lake Longganhu, respectively. The population of the microorganisms with various ecological nutrient transforming functions (e.g. phosphate solubilizing, denitrifying and cellulose decomposing) and a batch of environmental parameters concerning the nutrient accumulating and transforming (e.g. total organic carbon, total nitrogen, and total phosphorous concentrations) were assayed in the depth-related sediment samples from several defined points in both lakes. The sediment samples from Lake Chaohu showed higher density of actinomycetes (P<0.05) and phosphate-solubilizing bacteria (P<0.001) and less profusion of denitrifying bacteria (P<0.05) and cellulolytic microbes (P<0.001), compared with those of Lake Longganhu. The data suggested that the current microbial community in the sediment of Lake Chaohu is in favor of sustaining or further accelerating the process of the lake eutrophication. A possible positive feedback loop which consists of sustained growth of microorganisms and gradual decline of lake eutrophic status is worth further discussing. 相似文献
Environmental Science and Pollution Research - Municipal solid waste incineration (MSWI) fly ash has been classified as hazardous waste and needs treatment in an environmentally safe manner.... 相似文献
The aim of this study was to investigate the influence of chemical leaching on permeability and Cd removal from fine-grained polluted soils. Column leaching experiments were conducted using two types of soils (i.e., artificially Cd-polluted loam and historically polluted silty loam). Chemical agents of CaCl2, FeCl3, citric acid, EDTA, rhamnolipid, and deionized water were used to leach Cd from the soils. Results showed that organic agents reduced permeability of both soils, and FeCl3 reduced permeability of loam soil, compared with inorganic agents and deionized water. Entrapment and deposition of colloids generated from the organic agents and FeCl3 treatments reduced the soil permeability. The peak Cd effluence from the artificially polluted loam columns was retarded. For the artificially polluted soils treated with EDTA and the historically polluted soils with FeCl3, Cd precipitates were observed at the bottom after chemical leaching. When Cd was associated with large colloid particles, the reduction of soil permeability caused Cd accumulation in deeper soil. In addition, the slow process of disintegration of soil clay during chemical leaching might result in the retardation of peak Cd effluence. These results suggest the need for caution when using chemical-leaching agents for Cd removal in fine-grained soils.
Ultrafine particles (UFPs) pose a human health risk as they can penetrate deep into the respiratory system. The Harvard supersite in Boston, MA provides one of the longest time series of UFP concentrations. This study examined the hypothesis that long-term reductions in PM2.5 mass and sulfur have influenced UFP trends by limiting the ability of UFPs to coagulate onto the accumulation mode via polydisperse coagulation with larger particles. The study used Generalized Additive Models (GAMs) to assess whether changes in PM2.5 mass and sulfur concentrations resulted in smaller than expected (assuming no change in PM2.5 mass or sulfur) decreases in daily UFP trends over the 20-year period from 1999 to 2018. The impact of PM2.5 mass and sulfur changes were represented as UFP penalties. Bootstrapping was applied to calculate standard errors for the different trend and penalty estimates. Results showed that PM2.5 mass and sulfur concentrations declined significantly over the study period. The analysis found an estimated 7.3% (95% CI: 3.5, 11.1%) UFP penalty due to long-term PM2.5 mass trends, and a 9.9% (95% CI: 6.2, 13.7%) UFP penalty due to long-term sulfur trends. Findings from this study suggest that future UFP control efforts should account for the role of PM2.5 mass and sulfur changes. 相似文献
Organic carbon (OC) and elemental carbon (EC) in fine particles (PM2.5) at two background sites, Kosan and Kangwha in Korea were measured during intensive field studies between 1994 and 1999. Fine particles were collected on pre-fired quartz filters in a low-volume sampler and analyzed using the selective thermal oxidation method with MnO2 catalyst. The OC and EC concentrations at Kosan located at western tip of Cheju Island in southern Korea are lower than those at Kangwha located at western coastal area in mid-Korean peninsula. Still, the OC concentrations at Kosan are generally higher than those at other background areas in Japan and USA. The EC concentrations at Kosan are lower than or comparable to those at other background areas. The total carbon (TC, sum of OC and EC) to EC ratio values at both sites were higher than those at other background areas in Japan and USA. At Kosan, the OC and EC concentrations when air parcels were from southern China were higher than those when air parcels were coming from northern China. However, at Kangwha, the differences were statistically not clear since most air parcels were from northern China. Except when air parcels were from the North Pacific during summer, the OC and EC concentrations are well correlated indicating that both OC and EC share the same emission/transport characteristics. From the gaseous hydrocarbon data and the OC and EC relationship, it was found that during summer local biogenic emissions of OC might be significant at Kosan. 相似文献
The obvious disadvantages of biotrickling filters (BTFs) are the long start-up time and low removal efficiency (RE) when treating refractory hydrophobic volatile organic compounds (VOCs), which limits its industrial application. It is worthwhile to investigate how to reduce the start-up period of the BTF for treating hydrophobic VOCs. Here, we present the first study to evaluate the strategy of toluene induction combined with toluene-styrene synchronous acclimatization during start-up in a laboratory-scale BTF inoculated with activated sludge for styrene removal, as well as the effects of styrene inlet concentration (0.279 to 2.659 g·m?3), empty bed residence time (EBRT) (i.e., 136, 90, 68, 45, 34 sec), humidity (7.7% to 88.9%), and pH (i.e., 4, 3, 2.5, 2) on the performance of the BTF system. The experiments were carried out under acidic conditions (pH 4.5) to make fungi dominant in the BTF. The start-up period for styrene in the BTF was shortened to about 28 days. A maximum elimination capacity (ECmax) of 126 g·m?3·hr?1 with an RE of 80% was attained when styrene inlet loading rate (ILR) was below 180 g·m?3·hr?1. The highest styrene RE(s) [of BTF] that could be achieved were 95% and 93.4%, respectively, for humidity of 7.7% and at pH 2. A single dominant fungal strain was isolated and identified as Candida palmioleophila strain MA-M11 based on the 26S ribosomal RNA gene. Overall, the styrene induction with the toluene-styrene synchronous acclimatization could markedly reduce the start-up period and enhance the RE of styrene. The BTF dominated by fungi exhibited good performance under low pH and humidity and great potential in treating styrene with higher inlet concentrations.
Implications: The application of the toluene induction combined with toluene-styrene synchronous acclimatization demonstrated to be a promising approach for the highly efficient removal of styrene. The toluene induction can accelerate biofilm formation, and the adaptability of microorganisms to styrene can be improved rapidly by the toluene-styrene synchronous acclimatization. The integrated application of two technologies can shorten the start-up period of biotrickling filters markedly and promote its industrial application. 相似文献