首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   12篇
  免费   0篇
安全科学   3篇
综合类   1篇
基础理论   3篇
污染及防治   1篇
评价与监测   3篇
社会与环境   1篇
  2019年   2篇
  2017年   1篇
  2016年   2篇
  2015年   1篇
  2014年   1篇
  2013年   1篇
  2011年   1篇
  2010年   1篇
  2007年   1篇
  2006年   1篇
排序方式: 共有12条查询结果,搜索用时 328 毫秒
1.
Environmental Chemistry Letters - Research has recently focused on combinational therapy using nanocarriers to overcome the obstacles associated with conventional therapy of lung cancer. The...  相似文献   
2.

The combined exposure to aluminum (Al) and cadmium (Cd) causes more pronounced adverse health effects on humans. The kidneys are the main organs affected by internal exposure to Cd and Al via food and non-food items. The objective of present study was to measure the Al and Cd concentrations in cigarettes tobacco (branded and non-branded) and drinking water (domestic treated, ground and lake water) samples in southern part of Pakistan, to assess the risk due to ingestion of water and inhalation of cigarettes smoke containing high concentrations of both elements. The study population (kidney disorder and healthy) divided into two group based on consuming lake and ground water, while smoking non-branded cigarette as exposed, while drinking domestic treated water and smoking branded cigarette as non-exposed. Electrothermal atomic absorption spectrometry was used to determined Cd and Al concentrations in tobacco, drinking water and blood samples. The resulted data indicated that the levels of Al and Cd in lake and underground water were higher than the permissible limit in drinking water recommended by the World Health Organization. The biochemical parameters of exposed and referent patients, especially urinary N-acetyl-h-glucosaminidase, were used as a biomarkers of kidney disorder. Exposed kidney disorder patients have higher levels of Cd and Al than the exposed referents subjects, while difference was significant when compared to resulted data of non-exposed patients and referents (p = 0.01–0.001). The pearson correlation showed positive correlation between both toxic element concentrations in water, cigarettes versus blood samples of exposed subjects (r = 0.20–0.67 and 0.71–0.82), while lower values were observed for non-exposed subjects (r = 0.123–0.423 and 0.331–0.425), respectively.

  相似文献   
3.
The main objective of this study is to investigate and evaluate opportunities for implementation of pollution prevention and waste minimization in a chemical industrial company producing poly sulfonated naphthalene formaldehyde which is used as a super plasticizer for concrete. Environmental problems encountered were mainly the highly polluted wastewater and a semi-solid cake containing considerable amount of the final product. Possible modules for remedial measures and their cost estimation were investigated. The proposed remedial modules included recycling of retained water discharge in filter press, recycling of washing water of reaction vessels (reactors), closed circuit cooling system for high-pressure pump, good housekeeping through control of leakage of raw material, products and water and finally utilization of retained residual product from the solid waste. The implemented pollution control measures proved to be cost effective and have short payback periods. Also, minimization of the hydraulic and organic loads in the final effluent was achieved.  相似文献   
4.
In the current study, the chemistry of fresh and stored rainwater of Thar Desert, Pakistan, was estimated during two consecutive monsoon periods. The present research deals with the variation in physicochemical parameters, total arsenic (Ast), inorganic arsenic species (Asi, AsV, AsIII), and fluoride (F?) in stored rainwater (SRW) at different time intervals (1 week to 3 months). The pH of fresh rainwater (FRW) samples showed slightly acidic to neutral in nature (6.08–7.06) which were inconsistent with the reference pH value (5.6) of rainwater. The resulted data indicated that Ast and F? levels in SRW were enhanced with time duration. The levels of Ast and F? in SRW after different time intervals were found in the range of 194–683 μg/L and 10–35.4 mg/L, respectively. The values of Ast and F? were 20–70 and 7–24 times higher than those of WHO permissible limits, 10 μg/L and 1.5 mg/L, respectively. The AsIII was dominant species in SRW, which corresponds to >60 % of Asi. The characteristics of the SRW revealed an unacceptable quality to consume for drinking and agricultural purposes in the studied area.  相似文献   
5.
Objective: This article aims to evaluate the safety performance of cable median barriers on freeways in Florida.

Method: The safety performance evaluation was based on the percentages of barrier and median crossovers by vehicle type, crash severity, and cable median barrier type (Trinity Cable Safety System [CASS] and Gibraltar system). Twenty-three locations with cable median barriers totaling about 101 miles were identified. Police reports of 6,524 crashes from years 2005–2010 at these locations were reviewed to verify and obtain detailed crash information. A total of 549 crashes were determined to be barrier related (i.e., crashes involving vehicles hitting the cable median barrier) and were reviewed in further detail to identify crossover crashes and the manner in which the vehicles crossed the barriers; that is, by either overriding, underriding, or penetrating the barriers.

Results: Overall, 2.6% of vehicles that hit the cable median barrier crossed the median and traversed into the opposite travel lane. Overall, 98.1% of cars and 95.5% of light trucks that hit the barrier were prevented from crossing the median. In other words, 1.9% of cars and 4.5% of light trucks that hit the barrier had crossed the median and encroached on the opposite travel lanes. There is no significant difference in the performance of cable median barrier for cars versus light trucks in terms of crossover crashes. In terms of severity, overrides were more severe compared to underrides and penetrations. The statistics showed that the CASS and Gibraltar systems performed similarly in terms of crossover crashes. However, the Gibraltar system experienced a higher proportion of penetrations compared to the CASS system. The CASS system resulted in a slightly higher percentage of moderate and minor injury crashes compared to the Gibraltar system.

Conclusions: Cable median barriers are successful in preventing median crossover crashes; 97.4% of the cable median barrier crashes were prevented from crossing over the median. Of all of the vehicles that hit the barrier, 83.6% were either redirected or contained by the cable barrier system. Barrier crossover crashes were found to be more severe compared to barrier noncrossover crashes. In addition, overrides were found to be more severe compared to underrides and penetrations.  相似文献   

6.
Khan MH  Warwick P  Evans N 《Chemosphere》2006,63(7):1165-1169
A short, sensitive and reliable spectrophotometric method, which has advantages over all known "wet chemistry" methods for uranium determination with regard to tolerance to common interferences, has been developed for the determination of uranium. Selectivity, molar absorptivity and the determination range of uranium have been enhanced by using 0.07% arsenazo-III as a chromogenic reagent. The use of 3 mol dm(-3) perchloric acid as a medium of determination was found to be excellent in terms of good solvent compatibility on dilution, destruction of organic contamination and simplicity of operation. The uranium-arsenazo-III complex formed instantly, and was found to be stable for more than 3 weeks with constant absorbance. Beer's law was obeyed up to a uranium concentration of 16 microg g(-1), with a molar absorptivity at 651 nm of 1.45x10(5) mol(-1) dm(3) cm(-1) at 24+/-2 degrees C. Only phosphate and citrate at 70-fold excess over uranium interfere seriously, whereas other anions studied could be tolerated up to a 70-fold excess over uranium. Of the cations studied, only Mn(II), Co(II), Ni(II), Cu(II) and Cr(III) decreased the normal absorbance of the complex. Iron(III), Ce(III) and Y(III) enhanced the absorbance. Other cations studied did not affect the absorbance up to a 50-fold excess. The accuracy was checked by determining uranium from standard solutions in the range 10-50 microg g(-1). It was found to be accurate with a 96.0-98.6% recovery rate. The method has been successfully applied to standard reference materials and ore samples at microg g(-1) levels.  相似文献   
7.
8.
The present study was aimed to evaluate the cadmium (Cd) and lead (Pb) levels in the blood samples of adolescent boys, chewing different smokeless tobacco (SLT) products in Pakistan. For comparative purpose, boys of the same age group (12–15 years), not consumed any SLT products were selected as referents. To determine trace levels of Cd and Pb in blood samples, a preconcentration method, vortex-assisted liquid–liquid microextraction (VLLME) has been developed, prior to analysis by flame atomic absorption spectrometry. The hydrophobic chelates of Cd and Pb with ammonium pyrrolidinedithiocarbamate were extracted into the fine droplets of ionic liquid (IL) 1-butyl-3-methylimidazolium hexafluorophosphate, while nonionic surfactant, Triton X-114 was used as a dispersing medium. The main factors affecting the recoveries of Cd and Pb, such as concentration of APDC, centrifugation time, volume of IL and TX-114, were investigated in detail. It was also observed that adolescent boys who consumed different SLT products have 2- to 3-fold higher levels of Cd and Pb in their blood samples as compared to referent boys (p?<?0.001).  相似文献   
9.
The present work seeks to assess the sustainability of different solar photovoltaic (SPV) electricity-generating systems based upon energy, environment and economics. The sustainability indicators evaluated for energy, environment and economics are electrical output, life-cycle greenhouse gas (GHG) emissions and life-cycle cost of electricity generated per kilowatt hour. The selected SPV-based electricity generation technologies for sustainability evaluation are amorphous, monocrystalline and polycrystalline at different locations and tilt angles across India. For SPV systems, most of the emissions are the result of electricity use during manufacturing. In these cases, an average grid mix for the region of manufacture is typically used to calculate energy use and emissions. Based upon these three indicators, a figure of merit (FM) has been proposed. The results proposed that polycrystalline gives the maximum electrical output, minimum GHG emission, minimum cost and maximum FM at a radiation level of 6 kWh/m2/day with latitude and tilt angle of 34° and 35°, respectively. This work will be helpful to users of solar energy, academicians, researchers and other concerned persons, in understanding the importance, severity and benefits obtained by the application and implementation of the SPV electricity-generating systems.  相似文献   
10.
In this work, spectrophotometer was used as a detector for the determination of uranium from water, biological, and ore samples with a flow injection system coupled with solid phase extraction. In order to promote the online preconcentration of uranium, a minicolumn packed with XAD-4 resin impregnated with nalidixic acid was utilized. The system operation was based on U(VI) ion retention at pH 6 in the minicolumn at flow rate of 15.2 mL min?1. The uranium complex was removed from the resin by 0.1 mol dm?3 HCl at flow rate of 3.2 mL min?1 and was mixed with arsenazo III solution (0.05 % solution in 0.1 mol dm?3 HCl, 3.2 mL min?1) and driven to flow through cell of spectrophotometer where its absorbance was measured at 651 nm. The influence of chemical (pH and HCl (as eluent and reagent medium) concentration) and flow (sample and eluent flow rate and preconcentration time) parameters that could affect the performance of the system as well as the possible interferents was investigated. At the optimum conditions for 60 s preconcentration time (15.2 mL of sample volume), the method presented a detection limit of 1.1 μg L?1, a relative standard deviation (RSD) of 0.8 % at 100 μg L?1, enrichment factor of 30, and a sample throughput of 42 h?1, whereas for 300 s of the preconcentration time (76 mL of sample volume), a detection limit of 0.22 μg L?1, a RSD of 1.32 % at 10 μg L?1, enrichment factor of 150, and a sampling frequency of 11 h?1 were reported.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号