首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   31篇
  免费   0篇
安全科学   2篇
环保管理   3篇
综合类   4篇
基础理论   2篇
污染及防治   13篇
评价与监测   2篇
社会与环境   5篇
  2023年   1篇
  2020年   3篇
  2018年   1篇
  2017年   1篇
  2016年   3篇
  2014年   1篇
  2013年   2篇
  2011年   1篇
  2007年   3篇
  2006年   3篇
  2004年   4篇
  2003年   2篇
  2002年   1篇
  1999年   1篇
  1996年   1篇
  1993年   1篇
  1987年   1篇
  1985年   1篇
排序方式: 共有31条查询结果,搜索用时 31 毫秒
1.
An empirical moisture damage index was developed in order to reduce the subjectivity of the estimation of moisture damage in domestic residences, in relation to occupant health. The database was generated using information gathered from a sample of 164 houses that were examined by civil engineers, and questionnaire data collected from the occupants. The index was formulated to associate with the occupant reported respiratory symptoms by calculating weighted estimates of selected moisture damage attributes using 80% of the sample. The remaining 20% of the sample was used to verify the final index. The index associated strongly with the health symptoms of interest. This index is a tool that may be used as an indicator of moisture damage induced exposure in domestic residences.  相似文献   
2.
3.
The ability of pre-oxidation to overcome polycyclic aromatic hydrocarbons (PAH) recalcitrance to biodegradation was investigated in creosote contaminated soil. Sand and peat artificially spiked with creosote (quality WEI C) were used as model systems. Ozonation and Fenton-like treatment were proved to be feasible technologies for PAH degradation in soil. The efficiency of ozonation was strongly dependent on the water content of treated soil samples. The removal of PAH by Fenton-like treatment depended on the applied H2O2/soil weight ratio and ferrous ions addition. It was determined that the application of chemical oxidation in sand resulted in a higher PAH removal and required lower oxidant (ozone, hydrogen peroxide) doses. The enhancement of PAH biodegradability by different pre-treatment technologies also depended on the soil matrix. It was ascertained that combined chemical and biological treatment was more efficient in PAH elimination in creosote contaminated soil than either one alone. Thus, the combination of Fenton-like and the subsequent biological treatment resulted in the highest removal of PAH in creosote contaminated sand, and biodegradation with pre-ozonation was found to be the most effective technology for PAH elimination in peat.  相似文献   
4.
Weather station measurements were used to force the SNOWPACK snow model and combined with reindeer herders’ experiences to study the local and regional variations in snow conditions in a Finnish reindeer herding area for the 1981–2010 period. Winter conditions varied significantly between the four selected herding districts and between open and forest environments within the districts. The highest snow depths and densities, the thicknesses of ground ice, and the lengths of snow cover period were generally found in the northernmost districts. The snow depths showed the strongest regional coherence, whereas the thicknesses of ground ice were weakly correlated among the districts. The local variation in snow depths was higher than the regional variation and limits for rare or exceptional events varied notably between different districts and environments. The results highlight that forests diversify snow and foraging conditions, e.g., ground ice rarely forms simultaneously in different environments. Sufficient and diverse forest pastures are important during the critical winter season if reindeer herding is pursued on natural grazing grounds also in the future.  相似文献   
5.
6.
GOAL, SCOPE AND BACKGROUND: This study was carried out to investigate the effect of olive oil on the photodegradation of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in contaminated sawmill soil. Previous studies had shown that the solubility of PCDD/Fs in olive oil is high and a rapid photodegradation of PCDD/Fs takes place in olive oil when irradiated with ultraviolet (blacklight) lamps. The efficiency of this treatment method was evaluated under more practical conditions. These included the use of sunlight irradiation and a lower-grade olive oil, without a preliminary extraction of soil with olive oil. METHODS: A 1-cm layer of contaminated sawmill soil was blended with 20 weight-% of olive oil and exposed to sunlight for four weeks. In another experiment, a new dose of olive oil was added at the middle of the exposure period. The PCDD/F concentrations of the soils were monitored periodically. RESULTS AND DISCUSSION: A reduction in the concentration of 2,3,7,8-chlorinated PCDD/Fs by 59% and in WHO-TEQ in contaminated sawmill soil by 48% was attained after blending the soil with two doses (20 + 20%) of olive oil and exposing the mixture to sunlight for four weeks. Photodegradation with only one dose of olive oil was less efficient. This suggests that periodical additions of olive oil would be needed to maintain a proper degradation rate. After the oil additions, the WHO-TEQ content of the soil declined with first order reaction half-lives of 19.2 to 19.7 d. The overall half-life during the four-week treatment, however, was 30 d. CONCLUSION: A significant reduction in the PCDD/F concentration of aged sawmill soil can be achieved with a relatively simple olive oil-sunlight treatment. RECOMMENDATIONS AND OUTLOOK: Some theoretical and technological questions need to be solved before using the investigated soil decontamination method in larger-scale applications. The functions of vegetable oils in photodegradation processes should be studied in more detail. The amount of oil that is needed for a proper solubilisation and photodegradation of PCDD/Fs should be minimised. Moreover, special care should be taken to prevent mobilisation of PCDD/Fs to the surrounding environment and to avoid leaving bioavailable residuals of PCDD/Fs in soil.  相似文献   
7.

Objective

The purpose of this study was to explore the diagnostic yield and clinical utility of trio-based rapid whole exome sequencing (rWES) in pregnancies of fetuses with a wide range of congenital anomalies detected by ultrasound imaging.

Methods

In this observational study, we analyzed the first 54 cases referred to our laboratory for prenatal rWES to support clinical decision making, after the sonographic detection of fetal congenital anomalies. The most common identified congenital anomalies were skeletal dysplasia (n = 20), multiple major fetal congenital anomalies (n = 17) and intracerebral structural anomalies (n = 7).

Results

A conclusive diagnosis was identified in 18 of the 54 cases (33%). Pathogenic variants were detected most often in fetuses with skeletal dysplasia (n = 11) followed by fetuses with multiple major fetal congenital anomalies (n = 4) and intracerebral structural anomalies (n = 3). A survey, completed by the physicians for 37 of 54 cases, indicated that the rWES results impacted clinical decision making in 68% of cases.

Conclusions

These results suggest that rWES improves prenatal diagnosis of fetuses with congenital anomalies, and has an important impact on prenatal and peripartum parental and clinical decision making.  相似文献   
8.
The removal and transformation of natural organic matter were monitored in the different stages of the drinking water treatment train. Several methods to measure the quantity and quality of organic matter were used. The full-scale treatment sequence consisted of coagulation, flocculation, clarification by flotation, disinfection with chlorine dioxide, activated carbon filtration and post-chlorination. High-performance size-exclusion chromatography separation was used to determine the changes in the humic substances content during the purification process; in addition, a UV absorbance at wavelength 254 nm and total organic carbon amount were measured. A special aim was to study the performance and the capacity of the activated carbon filtration in the natural organic matter removal. Four of the activated carbon filters were monitored over the period of 1 year. Depending on the regeneration of the activated carbon filters, filtration was effective to a degree but did not significantly remove the smallest molar mass organic matter fraction. Activated carbon filtration was most effective in the removal of intermediate molar mass compounds (range 1,000-4,000 g/mol). Regeneration of the carbon improved the removal capacity considerably, but efficiency was returned to a normal level after few months.  相似文献   
9.
EN 14791 is a European Standard Reference method for the measurement of SO2 in emissions. This standard is based on a wet-chemical method in which SO2 present in flue gases is absorbed into an absorption solution containing hydrogen peroxide, and analyzed as sulfates after sampling. This study presents the results obtained when three portable automated measuring systems (P-AMS), based on Fourier-transform infrared (FTIR) spectroscopy, non-dispersive infrared (NDIR) and ultraviolet-fluorescence (UV) techniques, were compared to the Standard Reference Method for SO2 (EN 14791) in order to verify whether they could be used as alternative methods (AM) to EN 14791. In the case of FTIR, the measurements were performed from hot and wet gas, without any conditioning. UV-fluorescence analyzers were equipped with dilution probes and one NDIR applied a permeation dryer, whereas the other had a chiller. Tests were carried out at concentration ranges from 0 to 200 mg/m3(n) and from 0 to 800 mg/m3(n) for testing of equivalency according to CEN/TS 14793 using a test bench. Equivalency test criteria were met for all tested P-AMS except for NDIR at the lower range. The SO2 results measured with NDIR and the chiller were lower compared to the set-up with NDIR and permeation. This was most probably due to the chiller causing absorption of SO2 in the condensate. Tests were also carried out at field conditions, measuring the SO2 emissions from a boiler combusting mainly bark. The same phenomena were observed in these tests as during the test bench study, i.e. the measurement set-up with NDIR and the chiller gave the lowest results. These data demonstrated that the tested alternative methods (FTIR, UV-fluorescence, and NDIR) could be used instead of the standard reference method EN 14791, thus providing real-time calibration of automated measuring systems. It must however be emphasized that when measuring water-soluble gases, such as SO2, the choice of suitable conditioning technique is critical in order to minimize losses of the studied component in the condensate.

Implications: Portable automated measuring systems (P-AMS) provide real-time information about emissions and their concentrations, thus offering significant advantages compared to wet-chemical methods. This study presents results which can be used as a validation protocol to show that the tested P-AMS techniques (FTIR, NDIR, UV-fluorescence) could be used instead of EN 14791 (CEN 2017a) as alternative methods (AM), when paying attention to the selection of an appropriate conditioning technique.  相似文献   
10.

Objective

We performed a 1-year evaluation of a novel strategy of simultaneously analyzing single nucleotide variants (SNVs), copy number variants (CNVs) and copy-number-neutral Absence-of-Heterozygosity from Whole Exome Sequencing (WES) data for prenatal diagnosis of fetuses with ultrasound (US) anomalies and a non-causative QF-PCR result.

Methods

After invasive diagnostics, whole exome parent-offspring trio-sequencing with exome-wide CNV analysis was performed in pregnancies with fetal US anomalies and a non-causative QF-PCR result (WES-CNV). On request, additional SNV-analysis, restricted to (the) requested gene panel(s) only (with the option of whole exome SNV-analysis afterward) was performed simultaneously (WES-CNV/SNV) or as rapid SNV-re-analysis, following a normal CNV analysis.

Results

In total, 415 prenatal samples were included. Following a non-causative QF-PCR result, WES-CNV analysis was initially requested for 74.3% of the chorionic villus (CV) samples and 45% of the amniotic fluid (AF) samples. In case WES-CNV analysis did not reveal a causative aberration, SNV-re-analysis was requested in 41.7% of the CV samples and 17.5% of the AF samples. All initial analyses could be finished within 2 weeks after sampling. For SNV-re-analysis during pregnancy, turn-around-times (TATs) varied between one and 8 days.

Conclusion

We show a highly efficient all-in-one WES-based strategy, with short TATs, and the option of rapid SNV-re-analysis after a normal CNV result.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号