首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   40篇
  免费   0篇
废物处理   3篇
环保管理   4篇
综合类   2篇
基础理论   5篇
污染及防治   11篇
评价与监测   10篇
社会与环境   3篇
灾害及防治   2篇
  2022年   4篇
  2021年   4篇
  2019年   1篇
  2018年   1篇
  2016年   3篇
  2014年   1篇
  2013年   3篇
  2011年   2篇
  2010年   4篇
  2009年   2篇
  2008年   5篇
  2007年   1篇
  2005年   1篇
  2004年   3篇
  2003年   2篇
  1995年   1篇
  1994年   1篇
  1991年   1篇
排序方式: 共有40条查询结果,搜索用时 31 毫秒
1.
Environment, Development and Sustainability - This paper analyzed the relationship between environmental performance and tourism sector development in Mediterranean countries for the period from...  相似文献   
2.
Use of lignite in power generation has led to increasing environmental problems associated not only with gaseous emissions but also with the disposal of ash residues. In particular, use of low quality coal with high ash content results in huge quantities of fly ash to be disposed of. The main problem related to fly ash disposal is the heavy metal content of the residue. In this regard, experimental results of numerous studies indicate that toxic trace metals may leach when fly ash contacts water. In this study, fly ash samples obtained from thermal power plants, namely Soma and Tunçbilek, located at the west part of Turkey, were subjected to toxicity tests such as European Committee for standardization (CEN) and toxicity characteristic leaching (TCLP) procedures of the U.S. Environmental Protection Agency (U.S. EPA). The geochemical composition of the tested ash samples from the power plant show variations depending on the coal burned in the plants. Furthermore, the CEN and TCLP extraction results showed variations such that the ash samples were classified as `toxic waste' based on TCLP result whereas they were classified as `non-toxic' wastes based on CEN results, indicating test results are pH dependent.  相似文献   
3.
Drought in the northern part of Cyprus has become a recurrent phenomenon. In the last few decades, Cyprus has experienced significantly severe drought events occurring periodically, and this trend is now continuing. With rainfall distribution varying considerably across the region and frequent drought conditions, the water resources, agriculture, economy and the environment have been adversely affected. This study aims to investigate spatial–temporal characteristic of drought using Standardized Precipitation Index (SPI) at multiple timescales (3, 6 and 12 months). Monthly time series of 36 years (1977–2013) rainfall data from nine weather stations are used to derive SPI values. Based on different drought categories, this study focuses on propagation of drought from one timescale to another and estimating critical rainfall values during moderate, severe and extreme drought conditions. The analysis revealed that there is a strong correlation among different timescales in detecting drought events. On average, 79 and 78% of 3-month timescale drought propagated into 6- and 12-month drought events, respectively, while 90% of 6-month timescale drought events propagated into 12-month drought events. The derived critical rainfall value for extreme droughts over a 12-month timescale was less than 255 mm/year in the town of Alsancak, while for Guzelyurt, a major citrus growing city, this figure was less than 135 mm/year. The results are validated through drought events detected at various regions of the Mediterranean basin and local flood occurrences during the wet periods and decline in water tables at drought seasons.  相似文献   
4.
High winter-time PM10, sulfate, nitrate and ammonium levels in Istanbul were investigated using a high resolution WRF/CMAQ mesoscale model system. A model-ready anthropogenic emission inventory on 2 km spatial resolution was developed for the area and the present study is the first attempt to test these emissions. The results suggested that the system was capable of producing the magnitudes. PM10 levels calculated by the model underestimated the observations with an average of 10 per cent at Bogazici University sampling station, whereas an overestimation of 12 per cent is calculated for all stations. High uncertainties, particularly in traffic and coal combustion, led to over estimations around emission hot spots. Base case results together with the sensitivity studies pointed significant contribution of local sources, pointing to the need of control strategies focusing on primary particulate emissions.  相似文献   
5.
新疆煤田火灾的成因、危害及综合治理   总被引:3,自引:0,他引:3  
新疆是世界上煤田火灾最严重的地区,原因主要是新疆地处欧亚大陆腹地,具典型的大陆性干旱气候;新疆地区煤系为中下侏罗纪,地质活动较为剧烈;小煤窑的乱采滥挖等.新疆煤田火灾带来巨大危害:损失煤炭资源、污染环境、引发地质灾害、破坏生态平衡及危害生物健康等.对煤田火灾进行综合治理已经成为当务之急.为了有效灭火,应先对火区进行探测.探测方法有磁异常探测法、自然电场法和红外地面测温法等.然后因地制宜地选择适当的灭火技术进行灭火.灭火之后还应利用地理信息系统等方法对火区进行动态监测.  相似文献   
6.
The accumulations of Al, Cd, Cr, Cu, Fe, Ni, Pb and Zn in the exoskeleton, gills, hepatopancreas and abdominal muscles of crayfish Astacus leptodactylus (Eschscholtz, 1823) were determined. The strongest correlation observed was between Cr and Ni in the gills (r?=?0.904); moderate to strong correlations between Al, Cr, Fe, Ni and Cu were also observed in gill tissue. Disregarding the gills, the strongest correlation was found between Cu and Zn in the hepatopancreas (r?=?0.808); the correlation between these two metals might have been a result of metallothionein activity. The accumulation of Pb was found to correlate with that of Cd in the exoskeleton, Cd and Zn in the gills, Zn and Cu in the hepatopancreas and Cu in the abdominal muscle. None of these correlations were present in lakewater and sediment samples, suggesting that the crayfish metabolism may be responsible for the co-accumulation of metal–metal pairs. As all correlations in non-gill tissues are observed between divalent metals, a shared transporter such as divalent metal transporter 1 might be involved in the accumulation of these metals.  相似文献   
7.
Environmental Science and Pollution Research - The aim of this paper is to investigate the nexus between natural resources, gross capital formation, globalization, and economic growth in the...  相似文献   
8.
The air pollution is the one of the most important environmental problems in Erzurum, situated in the eastern of Turkey, during winter periods. The unfavorable climate as well as the city’s topography, and inappropriate urbanization cause serious air pollution problems. The air pollutant concentrations in a city have a close relationship with its meteorological parameters. In the present study, the relationship between daily average total suspended particulate (TSP) and sulphur dioxide (SO2) concentrations with meteorological factors, such as wind speed, temperature, relative humidity, pressure and precipitation, in 1995–2002 winter seasons was statistically analyzed using the stepwise multiple linear regression analysis. According to the results obtained through analysis, higher TSP and SO2 concentrations are strongly related to colder temperatures, lower wind speed, higher pressure system and weakly lower precipitation and higher relative humidity. The statistical models of SO2 and TSP including meteorological parameters gave R2 of 0.74 and 0.88, respectively. Furthermore, the correlation between the previous day’s SO2, TSP concentrations and actual concentrations of these pollutants on that day was investigated and found as 0.84 and 0.53, respectively. In order to develop this model, previous day’s SO2 and TSP concentrations were added to the equations. The new model for SO2 enhanced considerably (R2 = 0.92), but for TSP new model was not enhanced (R2 = 0.89).  相似文献   
9.
Locating an undesirable facility is a sophisticated problem, for the evaluation procedures involve several objectives and the solution to the problem calls for some compromises to be made between probable conflicting criteria. This paper addresses the problem of undesirable facility location selection using the analytic network process (ANP), a multi-criteria decision-making technique. The ANP technique enables us to consider both qualitative and quantitative criteria as well as the interdependencies and feedbacks. A number of criteria (benefits, opportunities, costs and risks) and their sub-criteria are considered for siting a new facility with which this study has dealt. The questions of what criteria would be considered and what the interdependencies between these criteria and their weights would be were discussed and determined via interviews with some competent authorities of the Istanbul Municipality and of two environmental organizations. Four representative locations were evaluated and the most convenient one was selected. This was followed by the sensitivity analyses of the results.  相似文献   
10.
The aim of this study was to determine the origin and quality of waters in Troia. For this purpose total of 25 water samples including 2 springs, 14 surfaces and 9 groundwaters, were collected at eight different times. Global positioning system (GPS) was used to determine to coordinates of sampling points. The concentration of 6 minor elements (B, Cu, F, Fe, Pb and Zn), 9 major anions and cations (Na(+), Ca(2+), K(+), Mg(2+), SO(4)(2-), PO(4)(3-), HCO(3)(-), Cl(-) and, CO(3)(2-)) were determined by spectrometric, colorimetric and volumetric methods. Water pH, EC, DO, ORP and TDS were measured in situ using probes. The data showed that the concentrations of most of minor elements were below the EPA and TSE limits except Pb which ranged between 0.001 and 4.832 mg L(-1). Statistically significant relationships (P<0.01 and r>0.70) were observed between Fe and Cu, Cu and K(+), Cu and Ca(2+), B and Na(+), Na(+) and K(+). Assessing the water based on irrigation using Wilcox model showed that some well waters were not suitable for irrigation. Troia water was found to be highly corrosive and the average corrosion coefficients varied from 0.5 to 4.6. According to the Piper and Schoeller diagrams results, the water in Troia was classified as mixed water type.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号