首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   214篇
  免费   3篇
  国内免费   10篇
安全科学   15篇
废物处理   26篇
环保管理   25篇
综合类   17篇
基础理论   39篇
污染及防治   85篇
评价与监测   15篇
社会与环境   5篇
  2023年   1篇
  2022年   3篇
  2021年   1篇
  2020年   1篇
  2019年   4篇
  2018年   8篇
  2017年   7篇
  2016年   7篇
  2015年   4篇
  2014年   7篇
  2013年   19篇
  2012年   11篇
  2011年   21篇
  2010年   16篇
  2009年   12篇
  2008年   24篇
  2007年   21篇
  2006年   13篇
  2005年   2篇
  2004年   13篇
  2003年   10篇
  2002年   8篇
  2001年   3篇
  2000年   3篇
  1998年   1篇
  1997年   1篇
  1996年   1篇
  1992年   1篇
  1989年   3篇
  1984年   1篇
排序方式: 共有227条查询结果,搜索用时 15 毫秒
1.
The study on the removal of NOx from simulated flue gas has been carded out in a lab-scale bubbling reactor using acidic solutions of sodium chlorite. Experiments were performed at various pH values and inlet NO concentrations in the absence or presence of SO2 gas at 45℃. The effect of SO2 on NO oxidation and NO2 absorption was critically examined. The oxidative ability of sodium chlorite was investigated at different pH values and it was found to be a better oxidant at a pH less than 4. In acidic medium, sodium chlorite decomposed into C102 gas, which is believed to participate in NO oxidation as well as in NO2 absorption. A plausible NOx removal mechanism using acidic sodium chlorite solution has been postulated. A maximum NOx removal efficiency of about 81% has been achieved.  相似文献   
2.
The mixing characteristics of a passive scalar in the turbulent flow of a selective catalytic reduction process were numerically and experimentally investigated, focusing especially on an injection nozzle with multiple holes for the reducing agent. The multihole injection nozzle studied has six holes that are perpendicular to the ambient flue gas flow and are located near the tip of the nozzle. Large eddy simulation was applied to the turbulent flow and mixing fields to elucidate the mixing mechanism of the proposed nozzle compared with the single-hole nozzle that is commonly used in the conventional selective catalytic reduction process. From the results, there exist broader regions of higher turbulent intensities for the multihole nozzle than for the conventional single-hole nozzle. These regions are well matched with the positions of high vorticity in the near upstream region of the jet flow issuing from the multiple holes of the nozzle. Consequently, the high turbulent intensities and vorticity magnitudes lead to intensified mixing between the flue gas and the reducing agent. Hence, the most suitable molar ratio between NOx and the reducing agent for the catalytic reaction can be easily obtained within a shorter physical mixing length as a result of the enhanced scalar mixing. Finally, the numerical results were applied to a trial design version of a multihole nozzle, and this nozzle was experimentally tested to confirm its mixing performance.  相似文献   
3.
Diadromous fish often enter freshwater directly from seawater via fish ladders or channels built in estuarine dams. The oxygen consumption rates (OCR) of glass eel, Anguilla japonica, were determined using an automatic intermittent flow respirometer under various salinity and temperature regimes to physiologically explain this direct movement. The endogenous rhythm of the OCR in wild glass eels, freshly collected from estuaries, was nearly synchronous with the tidal pattern at the estuarine collection site. When the salinity was changed from 20 psu (12°C) at a constant temperature to that of freshwater, the OCR of the glass eels decreased by 21.6±7.0% (mean ± SD) (P<0.05), showing a dampened rhythm for about 48 h. After this period of impediment, the glass eels resumed normal metabolic activity. Direct migration from seawater to freshwater under constant temperature would result in a severe physiological stress for these glass eels for about two days. When the glass eels were exposed to a cyclic change in water temperature of 2°C 26 h−1, as they encounter in estuaries, and then were introduced to freshwater abruptly, the OCR rhythm corresponded to the cyclic changes in water temperature after exposure to freshwater. Under these conditions, the mean OCR of the glass eels had a small difference before and after exposure to freshwater. These data explained how glass eels can directly move from sea water into the freshwater without any apparent metabolic stress in the estuaries showing cyclic change in water temperature (Δt=2°C).  相似文献   
4.
/ A methodology to estimate the number of pump-out facilities and dump stations required to service human waste disposal for recreational power boating activities in Pennsylvania during the 1994 boating season is described. Study results suggest that a total of 39 additional pump-out stations and 13 dump stations may be required on seven major waterbodies: The Three Rivers Area, Lake Erie/Presque Isle Bay, Raystown Lake, the Susquehanna River, the Delaware River, Lake Wallenpaupack, and the Kinzua Reservoir. Suggestions for improving the methodology are provided. KEY WORDS: Human waste; Recreation; Power boating; Waste facilities; Waste disposal; Pennsylvania  相似文献   
5.
Arsenite [As(III)]-oxidizing bacteria play important roles in reducing arsenic [As] toxicity and mobility in As-contaminated areas. As-resistant bacteria were isolated from the soils of two abandoned mines in the Republic of Korea. The isolated bacteria showed relatively high resistances to As(III) up to 26 mM. The PCR-based 16S rRNA analysis revealed that the isolated As-resistant bacteria were close relatives to Serratia marcescensa, Pseudomonas putida, Pantoea agglomerans, and Alcaligenes sp. Among the five As-resistant bacterial isolates, Alcaligenes sp. strain RS-19 showed the highest As(III)-oxidizing activity in batch tests, completely oxidizing 1 mM of As(III) to As(V) within 40 h during heterotrophic growth. This study suggests that the indigenous bacteria have evolved to retain the ability to resist toxic As in the As-contaminated environments and moreover to convert the species to a less toxic form [e.g., from As(III) to As(V)] and also contribute the biogeochemical cycling of As by being involved in speciation of As.  相似文献   
6.
Ambient air monitoring of PCDD/Fs and co-PCBs in Gyeonggi-do, Korea   总被引:3,自引:0,他引:3  
Kim DG  Min YK  Jeong JY  Kim GH  Kim JY  Son CS  Lee DH 《Chemosphere》2007,67(9):1722-1727
We started the monitoring for PCDD/Fs in ambient air and soil in August 2001, and co-PCBs in January 2002. Decreasing of PCDD/Fs and co-PCBs levels in ambient air were observed. The higher PCDD/Fs levels were found in winter and lower in autumn. We found that the industrial incinerators influenced the PCDD/Fs levels in ambient air. In the 2,3,7,8-substituted PCDD/Fs concentration profiles, the three major congeners occupied 67% of the total mass. In case of co-PCBs, PCB#118, #105 and #77 were observed as the main congeners. Five cluster groups discriminated by ratio of four components, O(8)CDD, 1,2,3,4,6,7,8-H(7)CDD, 1,2,3,4,6,7,8-H(7)CDF and O(8)CDF, were obtained from HCA (hierarchical cluster analysis).  相似文献   
7.
Polyvinylchloride (PVC) was successfully recycled through the solvent extraction from waste pipe with an extraction yield of ca. 86%. The extracted PVC was pyrolyzed by a two-stage process (260 and 410 degrees C) to obtain free-chlorine PVC based pitch through an effective removal of chlorine from PVC during the heat-treatment. As-prepared pitch (softening point: 220 degrees C) was spun, stabilized, carbonized into carbon fibers (CFs), and further activated into activated carbon fibers (ACFs) in a flow of CO2. As-prepared CFs show comparable mechanical properties to commercial CFs, whose maximum tensile strength and modulus are 862 MPa and 62 GPa, respectively. The resultant ACFs exhibit a high surface area of 1200 m2/g, narrow pore size distribution and a low oxygen content of 3%. The study provides an effective insight to recycle PVC from waste PVC and develop a carbon precursor for high performance carbon materials such as CFs and ACFs.  相似文献   
8.
Efficient removal of chlorine from PVC achieved by two-stage heat-treatment (280 and 410 degrees C) provided chlorine-free isotropic pitch containing additive. The pitch was stabilized and carbonized into porous carbons with surface areas of approximately 300 m2/g. Resultant porous carbons showed three pore structures of supermicropore, micropore and mesopore. The generation of CO2 from the decomposition of the CaCO3 additive in waste PVC is responsible for the development of porous structures. The surface area of the carbonized product increased after the removal of CaO.  相似文献   
9.

Background, aims, and scope

Preschool indoor air quality (IAQ) is believed to be different from elementary school or higher school IAQ and preschool is the first place for social activity. Younger children are more susceptible than higher-grade children and spend more time indoors. The purpose of this study was to compare the indoor air quality by investigating the concentrations of airborne particulates and gaseous materials at preschools in urban and rural locations in Korea.

Methods

We investigated the concentrations of airborne particulates and gaseous materials in 71 classrooms at 17 Korean preschools. For comparison, outdoor air was sampled simultaneously with indoor air samples. Airborne concentrations of total suspended particulates, respirable particulates, lead, asbestos, total volatile organic compounds and components, formaldehyde, and CO2 were measured with National Institute for Occupational Safety and Health and/or Environmental Protection Agency analytical methods.

Results

The concentration profiles of the investigated pollutants in indoor and urban settings were higher than those in outdoor and rural areas, respectively. The ratios of indoor/outdoor concentrations (I/O) of particulates and gaseous pollutants were characterized in urban and rural preschools. Total dust concentration was highest in urban indoor settings followed by urban outdoor, rural indoor, and rural outdoor locations with an I/O ratio of 1.37 in urban and 1.35 in rural areas. Although I/O ratios of lead were close to 1, lead concentrations were much higher in urban than in rural areas. The I/O ratio of total VOCs was 2.29 in urban and 2.52 in rural areas, with the highest level in urban indoor settings. The I/O ratio of formaldehyde concentrations was higher in rural than in urban areas because the outdoor rural level was much lower than the urban concentration. Since an I/O ratio higher than 1 implies the presence of indoor sources, we concluded that there are many indoor sources in preschools.

Conclusions

We confirmed that pollutants in indoor and urban settings were higher than those in outdoor and rural areas, respectively. Preschool children are expected to spend more time inside preschool facilities and therefore to be more exposed to pollutants. As far as we know, preschool IAQ is different from elementary school or higher school IAQ. Also, they are more vulnerable than higher-grade children. We found that the indoor and urban concentration profiles of the studied pollutants in preschools were higher than those in outdoor and rural areas. We believe that our findings may be useful for understanding the potential health effects of exposure and intervention studies in preschools.  相似文献   
10.
This study was conducted to assess inhalation exposure to dust, endotoxin, and microorganisms (including viable bacteria, Gram-negative bacteria [GNB], and fungi) during waste collection and sorting; to identify factors affecting this exposure; and to estimate the gastrointestinal exposure to microorganisms. A total of 48 or 49 workers involved in collecting and sorting waste from households or the street were studied. Each worker carried two personal samplers in which filters were placed in the breathing zone for estimation of inhalation exposure. To assess the possibility of gastrointestinal exposure, microorganisms on the workers' faces were collected before and after work and compared with those collected from office workers. Inhalation exposure levels were categorized according to job title, waste type handled, and working conditions and were compared using analysis of variance. Multiple regression models were developed to identify those factors that substantially affected inhalation exposure. The average exposure level to total dust was 0.9 mg/m3 (range = 0.05 to 4.51 mg/m3), and the average exposure to endotoxin was 1123 EU/m3. The average respective exposure levels to bacteria, GNB, and fungi each exceeded 10(4) colony forming units (CFU)/m3. The multiple regression models found several factors that significantly explained the variation in levels of inhalation exposure to endotoxin and microorganisms; namely, sex (dust, bacteria, and GNB), job title (GNB and fungi), collection day (dust, bacteria, and GNB), temperature (endotoxin and GNB), humidity (endotoxin and fungi), and region (endotoxin) were significantly associated with exposure to these agents. In addition, the workers' faces were highly contaminated with microorganisms. In conclusion, inhalation exposure to endotoxin and microorganisms was high during waste collection and sorting, which may place workers at risk of developing various health problems, including respiratory complaints.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号