排序方式: 共有58条查询结果,搜索用时 31 毫秒
1.
Rats (Rattus norvegicus) were intraperitoneally injected with a 100 mg kg(-1) dosage of benzene, a toxic and carcinogenic agent widely used for industrial purposes. Changes in lactate dehydrogenase (LDH), alkaline phosphatase (ALP), alanine amino transferase (ALT), aspartate amino transferase (AST) activities in serum of rats were investigated at 2, 4, 8, 16, 32, and 64 h following injection. Serum physiological was administered to control group. Activities were measured using autoanalyzer. Benzene caused significant activations in LDH, ALP, and AST activities in the serum at some test hours (p < 0.05). When compared with the control groups, although an increase occurred in ALT activity, it was seem that this increase wasn't significant (p > 0.05). 相似文献
2.
Adem Asan Rukiye Aydin Deniz Karsli Semiz Vildan Erci Ibrahim Isildak 《Environmental monitoring and assessment》2013,185(3):2115-2121
In this study, an ultra-sensitive and highly selective, rapid flow-injection spectrophotometric method for the determination of iron (II) and total iron has been proposed. The method was based on the reaction between iron (II) and 2′, 3, 4′, 5, 7-pentahydroxyflavone in slightly acidic solution with a strong absorption at 415 nm. The carrier solution used was 1?×?10?5 M 2′, 3, 4′, 5, 7-pentahydroxyflavone in 0.1 M HAc/Ac? buffer solution at pH 4.5. Parameters that affect simultaneously the determination of iron (II) and interfering ions were tested. The relative standard deviation for the determination of 50 μg L?1 iron (II) was 0.85 % (n?=?10), and the limit of detection (blank signal plus three times the standard deviation of the blank) was 3 μg L?1, both based on injection volumes of 20 μL. The method has been successfully applied to the determination of iron (II) and total iron in water samples and ore samples. The method was verified by analysing a certified reference material Zn/Al/Cu 43XZ3F. 相似文献
3.
The aim of this study was to determine the level of 26 polycyclic aromatic hydrocarbons (PAHs) at parking garages and to provide the necessary annual information based on occupational inhalation exposure and non-occupational inhalation exposure, which carry risks for the environment. For this purpose, 22 samples were collected continuously from both gas and particulates phase PAHs from two parking garages at Konya City Center, Turkey. The exposure-based risk of these samples was evaluated using concentrations of the carcinogenic PAH compounds. None of the 26 PAHs measured had values exceeding the recommended exposure limits (RELs) standard values for inhalation rate recommended by the World Health Organization (WHO). Exposure levels of gas and particulate PAHs for the occupational group and the public (children and adults who spend time in shopping centers) were found to be 0.07–28.24 μgm?3 and 0.05–5.753 μgm?3, respectively, representing levels two to four times higher than those at the control site. Maximum daily inhalation of B[a]Py was estimated at 1.33 ngd?1 for exposure of the public and as 274 ngd?1 for the occupational group. It is believed that traffic makes a substantial contribution to the PAH profile, which had relatively high concentrations of naphthalene (Napth) and coronene (Coro). Highly carcinogenic dibenzo(a,l)pyrene (B[al]Pyre) was found in the ambient air at two parking garages. Napth and phenanthrene (Phen) were the main compounds found in nearly all the tested samples. In this study, benzo[e]pyrene (B[e]Py) was used as a reference for PAHs because its concentration is stable and does not change seasonally. Considering the importance of these compounds in relation to human health, the aim of this work was to characterize and quantify the more toxic PAHs in parking garages. Conducting PAH sampling and their chemical analysis is very costly and labor intensive. This study produced data that can be a powerful tool for environmental forensics. 相似文献
4.
Mehmet Berkun Egemen Aras Tugce Anılan 《Journal of Material Cycles and Waste Management》2011,13(4):305-313
As an economically developing country, Turkey has very well operated integrated solid waste management applications structured
on modern facilities, besides over 2,000 scattered open dump areas in the country. Integrated waste management applications
seem eligible for the metropolitan cities like Istanbul and Izmit (Kocaeli). Attempts have not been encouraging for the scattered
regional settlements using central storage sites due to financial shortages and received rejections from nearby settlements.
Small-scale compact solid waste management systems with materials recycling and composting can be more suitable alternatives
in the small-scale regional settlements. The major constituents of municipal solid waste are organic in nature and approximately
a quarter of municipal solid waste is recyclable. Although paper, including cardboard, is the main constituent, the composition
of recyclable waste varies strongly by the source or the type of collection point. Solid wastes need primary treatment in
order to be suitable for incineration and composting. Turkey needs to give more emphasis on the usage of modern solid waste
removal technologies to overcome the overgrowing solid waste disposal problems. 相似文献
5.
This paper focuses on the exergetic sustainability indicators of a medium-range commercial aircraft engine for constant reference environment and ground running conditions. First, a detailed exergy analysis of turbofan engine have been performed based on engine test cell parameters. Starting from the sustainability considerations and the second law of the thermodynamics, the paper presents six exergy-based sustainability indicators. The indicators of the turbofan engine developed here in conjunction with exergetic analysis and sustainable development are exergy efficiency, waste exergy ratio, exergy destruction factor, recoverable exergy rate, environmental effect factor, and exergetic sustainability index. The investigated sustainable indicators have been calculated by using exergy analysis outputs for aircraft ground running condition. Results from this study show that values of exergy efficiency, waste exergy ratio, exergy destruction factor, recoverable exergy rate, environmental effect factor, and exergetic sustainability index of investigated turbofan engine are found to be 0.315, 0.685, 0.408, 0, 2.174, and 0.460, respectively. These parameters are expected to quantify how the turbofan engine and aircraft become more environmentally benign and sustainable. 相似文献
6.
Worldwide energy demand has been growing steadily during the past five decades and most experts believe that this trend will continue to rise. The amount of emitted harmful emission gases increases in parallel with increasing energy consumption. This increase has forced many countries to take various precautions, and various restrictions on emitted emissions have been carried. In this study, effects of addition of oxygen containing nanoparticle additives to biodiesel on fuel properties and effects on diesel engine performance and exhaust emissions were investigated. Two different nanoparticle additives, namely MgO and SiO2, were added to biodiesel at the addition dosage of 25 and 50 ppm. Fuel properties, engine performance, and exhaust emission characteristics of obtained modified fuels were examined. As a result of this study, engine emission values NOx and CO were decreased and engine performance values slightly increased with the addition of nanoparticle additives. 相似文献
7.
8.
9.
10.
Tufekcioglu A Guner S Kucuk M 《Journal of environmental biology / Academy of Environmental Biology, India》2004,25(3):317-320
In this study, influence of slope position (south-facing vs. north-facing), species type and sampling time on fine (0-2 mm), small (2-5 mm) and coarse (5-10 mm) root biomass and carbon storage of oriental spruce (Picea orientalis) and oriental beech (Fagus orientalis) were investigated. Mean total root biomass of oriental spruce was 20160 kg ha(-1) in south-facing slopes and 17140 kg ha(-1) in north-facing slopes. Mean total belowground C storage of oriental spruce was 7861 kg ha(-1) in south-facing slopes and 6840 kg ha(-1) in north-facing slopes. Similarly, biomass and C storage of oriental beech were 17190 and 6690 kg ha(-1) in south-facing slopes, and 13260 and 5200 kg ha(-1) in north-facing slopes, respectively. Oriental spruce had significantly higher fine root biomass than did oriental beech in south-facing slopes. Fine root biomass was significantly higher in fall than in spring in south-facing slopes. 相似文献