首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
废物处理   3篇
污染及防治   3篇
  2022年   1篇
  2014年   2篇
  2011年   1篇
  2008年   2篇
排序方式: 共有6条查询结果,搜索用时 15 毫秒
1
1.
This study focuses on the verification of test interpretations for different state analyses of diffusion experiments. Part 1 of this study identified that steady, quasi-steady and equilibrium state analyses for the through- and in-diffusion tests with solution reservoirs are generally feasible where the tracer is not highly sorptive. In Part 2 we investigate parameter identifiability in transient-state analysis of reservoir concentration variation using a numerical approach. For increased generality, the analytical models, objective functions and Jacobian matrix necessary for inverse analysis of transient-state data are reformulated using unified dimensionless parameters. In these dimensionless forms, the number of unknown parameters is reduced and a single dimensionless parameter represents the sorption property. The dimensionless objective functions are evaluated for individual test methods and parameter identifiability is discussed in relation to the sorption property. The effects of multiple minima and measurement error on parameter identifiability are also investigated. The main findings are that inverse problems for inlet and outlet reservoir concentration analyses are generally unstable and well-posed, respectively. Where the tracer is sorptive, the inverse problem for the inlet reservoir concentration analysis may have multiple minima. When insufficient measurement data is collected, multiple solutions may result and this should be taken into consideration when inversely analyzing data including that of inlet reservoir concentration. Verification of test interpretation by cross-checking different state analyses is feasible where the tracer is not highly sorptive. In an actual experiment, test interpretation validity is demonstrated through consistency between theory and practice for different state analyses.  相似文献   
2.
Diffusion anisotropy is a critical property in predicting migration of substances in sedimentary formations with very low permeability. The diffusion anisotropy of sedimentary rocks has been evaluated mainly from laboratory diffusion experiments, in which the directional diffusivities are separately estimated by through-diffusion experiments using different rock samples, or concurrently by in-diffusion experiments in which only the tracer profile in a rock block is measured. To estimate the diffusion anisotropy from a single rock sample, this study proposes an axisymmetric diffusion test, in which tracer diffuses between a cylindrical rock sample and a surrounding solution reservoir. The tracer diffusion between the sample and reservoir can be monitored from the reservoir tracer concentrations, and the tracer profile could also be obtained after dismantling the sample. Semi-analytical solutions are derived for tracer concentrations in both the reservoir and sample, accounting for an anisotropic diffusion tensor of rank two as well as the dilution effects from sampling and replacement of reservoir solution. The transient and steady-state analyses were examined experimentally and numerically for different experimental configurations, but without the need for tracer profiling. These experimental configurations are tested for in- and out-diffusion experiments using Koetoi and Wakkanai mudstones and Shirahama sandstone, and are scrutinized by a numerical approach to identify favorable conditions for parameter estimation. The analysis reveals the difficulty in estimating diffusion anisotropy; test configurations are proposed for enhanced identifiability of diffusion anisotropy. Moreover, it is demonstrated that the axisymmetric diffusion test is efficient in obtaining the sorption parameter from both steady-state and transient data, and in determining the effective diffusion coefficient if isotropic diffusion is assumed. Moreover, measuring reservoir concentrations in an axisymmetric diffusion experiment coupled with tracer profiling may be a promising approach to estimate of diffusion anisotropy of sedimentary rocks.  相似文献   
3.
To obtain reliable diffusion parameters for diffusion testing, multiple experiments should not only be cross-checked but the internal consistency of each experiment should also be verified. In the through- and in-diffusion tests with solution reservoirs, test interpretation of different phases often makes use of simplified analytical solutions. This study explores the feasibility of steady, quasi-steady, equilibrium and transient-state analyses using simplified analytical solutions with respect to (i) valid conditions for each analytical solution, (ii) potential error, and (iii) experimental time. For increased generality, a series of numerical analyses are performed using unified dimensionless parameters and the results are all related to dimensionless reservoir volume (DRV) which includes only the sorptive parameter as an unknown. This means the above factors can be investigated on the basis of the sorption properties of the testing material and/or tracer. The main findings are that steady, quasi-steady and equilibrium-state analyses are applicable when the tracer is not highly sorptive. However, quasi-steady and equilibrium-state analyses become inefficient or impractical compared to steady state analysis when the tracer is non-sorbing and material porosity is significantly low. Systematic and comprehensive reformulation of analytical models enables the comparison of experimental times between different test methods. The applicability and potential error of each test interpretation can also be studied. These can be applied in designing, performing, and interpreting diffusion experiments by deducing DRV from the available information for the target material and tracer, combined with the results of this study.  相似文献   
4.
End-of-life vehicles (ELV) have become a global concern as automobiles have become popular worldwide. An international workshop was held to gather data and to discuss 3R policies and ELV recycling systems, their background and present situation, outcomes of related policies and programs, the framework of recycling and waste management, and case studies on related topics in several countries and regions, as well as the essential points of the comparison. Legislative ELV recycling systems are established in the EU, Japan, Korea, and China, while in the US, ELV recycling is managed under existing laws on environmental protection. Since automobile shredding residue (ASR) has a high calorific value and ash content, and includes heavy metals as well as a mass of unclassified fine particles, recycling ASR is considered highly difficult. Countries with a legislative ELV system commonly set a target for recovery rates, with many aiming for more than 95 % recovery. In order to reach this target, higher efficiency in ASR recovery is needed, in addition to material recycling of collectable components and metals. Environmentally friendly design was considered necessary at the planning and manufacturing stages, and the development of recycling systems and techniques in line with these changes are required for sound ELV management.  相似文献   
5.
6.
Journal of Material Cycles and Waste Management - The radioactive cesium (radio-Cs) released following the Fukushima Daiichi Nuclear Power Plant accident was unevenly distributed in soil, sediment,...  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号