首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   73篇
  免费   0篇
  国内免费   1篇
安全科学   5篇
废物处理   10篇
环保管理   4篇
综合类   5篇
基础理论   15篇
污染及防治   22篇
评价与监测   7篇
社会与环境   6篇
  2023年   1篇
  2022年   11篇
  2021年   4篇
  2020年   1篇
  2019年   5篇
  2018年   3篇
  2017年   8篇
  2016年   3篇
  2015年   2篇
  2014年   6篇
  2013年   6篇
  2012年   4篇
  2011年   4篇
  2010年   1篇
  2009年   2篇
  2008年   4篇
  2007年   2篇
  2006年   1篇
  2005年   1篇
  1992年   1篇
  1991年   2篇
  1986年   1篇
  1968年   1篇
排序方式: 共有74条查询结果,搜索用时 31 毫秒
1.
Environmental Science and Pollution Research - For elimination of cesium from aqueous solutions, mesoporous SBA-15 was synthesized and employed as the support for immobilization of potassium copper...  相似文献   
2.
Enteric viruses monitoring in surface waters requires the concentration of viruses before detection assays. The aim of this study was to evaluate different methods in terms of recovery efficiencies of bacteriophage PP7 of Pseudomonas aeruginosa, measured by real-time PCR, using it as a viral control process in water analysis. Different nucleic acid extraction methods (silica–guanidinium thiocyanate, a commercial kit (Qiagen Viral RNA Kit) and phenol–chloroform with alcohol precipitation) exhibited very low recovery efficiencies (0.08–4.18 %), being the most efficient the commercial kit used for subsequent experiments. To evaluate the efficiency of three concentration methods, PBS (as model for clean water) and water samples from rivers were seeded to reach high (HC, 106 pfu ml?1) and low concentrations (LC, 104 pfu ml?1) of PP7. Tangential ultrafiltration proved to be more efficient (50.36?±?12.91, 17.21?±?9.22 and 12.58?±?2.35 % for HC in PBS and two river samples, respectively) than adsorption–elution with negatively charged membranes (1.00?±?1.34, 2.79?±?2.62 and 0.05?±?0.08 % for HC in PBS and two river samples, respectively) and polyethylene glycol precipitation (15.95?±?7.43, 4.01?±?1.12 and 3.91?±?0.54 %, for HC in PBS and two river samples, respectively), being 3.2–50.4 times more efficient than the others for PBS and 2.7–252 times for river samples. Efficiencies also depended on the initial virus concentration and aqueous matrixes composition. In consequence, the incorporation of an internal standard like PP7 along the process is useful as a control of the water concentration procedure, the nucleic acid extraction, the presence of inhibitors and the variability of the recovery among replicas, and for the calculation of the sample limit of detection. Thus, the use of a process control, as presented here, is crucial for the accurate quantification of viral contamination.  相似文献   
3.
Introduction. Most work-related musculoskeletal disorders (MSDs) are associated with improper postures and poorly designed workstations. This study is an attempt to examine the prevalence and severity of MSDs as well as anthropometric dimensions among city bus drivers. Methodology. This cross-sectional study was carried out on 60 male bus drivers. A body discomfort chart was used to evaluate MSDs. Spearman correlation was employed to examine the relationship between body size and the severity of discomfort. Results. Data analysis showed that discomfort reported in the lower back (33.3%), upper back (18.3%) and knee (15%) was severe and there was a direct and significant correlation between the body mass index and the severity of discomfort in the shoulder, arm and hip (p?p?Conclusion. The results of the study can be used to address ergonomic risk factors and reduce their associated disorders. The findings of the study can be used in training programs to educate drivers how to decrease the risk associated with work-related MSDs by adopting appropriate behavior strategies.  相似文献   
4.
During the production of thermonuclear fusion weapons at the Y‐12 National Security Complex (Y‐12 NSC) in Oak Ridge, Tennessee, between 1950 and 1963, the regional environment was extensively contaminated by volatile organic compounds (VOCs). Old Salvage Yard (OSY) on the western side of the site has been characterized as the major source of VOCs. In order to analyze the long‐term fate and transport of chlorinated VOC sources, an integrated surface and subsurface flow and transport model was developed for the Y‐12 NSC using the hydrodynamic and transport numerical package MIKE‐SHE. The model was developed considering the recent hydrogeological investigations on preferential flow and transport pathways at the site. The model was calibrated using the recorded groundwater flow and water‐quality data. The modeling simulated migration of the VOC plume for the next 100 years. Considering a range of hydrogeological and transport parameters, uncertainty of the results is discussed. The modeling predicted that tetrachloroethene, trichloroethene, and 1,2‐dichloroethene may exceed human health–related risk levels for the next 10 to 20 years. However, the contamination is unlikely to migrate to surface water under the current hydrogeological conditions and will decay below acceptable risk levels within approximately 20 years. © 2013 Wiley Periodicals, Inc.  相似文献   
5.
The Monterrey Metropolitan Area (MMA) is the third largest city in Mexico. Few studies have been carried out regarding its air pollution. The aim of this study was to analyze the temporal behavior of PM10 (particulate matter < or =10 microm in aerodynamic diameter). Data reported by the "Sistema Integral de Monitoreo Ambiental" (Integrated Environmental Monitoring System) network from 2006 to 2008 were used. PM10 levels were compared among the stations by year, season, and day of week. A bootstrap technique was used to obtain subsamples to which Student's t test and ANOVA were applied. PM10 levels were high and exceeded the annual limit of 50 microg/m3 set up by the Mexican standard Norma Oficial Mexicana NOM-025-SSA1-1993. These levels could have serious health effects. The southwest zone of MMA had the highest levels of PM10 during the period studied. Winter was the most polluted season, and summer was the least polluted season. Thursday and Friday were the most polluted days, and Sunday was the least polluted day. The hours with the highest levels of PM10 were 8:00 to 10:00 a.m., whereas nighttime hours were the cleanest.  相似文献   
6.
The underground temperature at a depth of about 3–4 m is almost constant all the year round. In summer, the underground temperature is lower than the ambient temperature, but in winter it is vice versa. This potentiality is considered for greenhouse cooling and heating by using an earth-to-air heat exchanger (EAHE). This paper considers the effects of two parameters as independent variables including the area of greenhouse and the percentage of vegetation coverage inside the greenhouse on the performance of an EAHE system during both cooling and heating modes. The inside temperature, the thermal energy exchange and the coefficient of performance (COP) of the system were considered as dependent variables. The results showed that both greenhouse area and the percentage of vegetation coverage inside the greenhouse had significant effects on the performance of the EAHE system during both cooling and heating modes. However, the COP of the EAHE system was higher in the cooling mode (4.32) than during the heating mode (1.01). The percentage of vegetation coverage negatively affected the performance of the EAHE system in the cooling mode. However, the performance of the EAHE system improved with the increase in the percentage of vegetation coverage during the heating mode.  相似文献   
7.
In the present article, a simple, rapid, sensitive and economical method has been developed for the simultaneous separation and preconcentration of the trace amounts of copper, nickel, cobalt and manganese in water samples by using modified XAD-4 resins. The sorption was quantitative in the pH range 6.0–9.0, whereas quantitative desorption occurred instantaneously with 5.0 mL of 2 M HNO3, and selected elements have been determined by using flame atomic absorption spectrometry. Dynamic ranges were 0.04–3.5, 0.1–6.0, 0.04–4.5 and 0.04–4.0 μg/mL for copper, nickel, cobalt and manganese, respectively. The detection limits were 9.2, 28.6, 12.3 and 5.7 ng/mL for Cu(II), Ni(II), Co(II) and Mn(II), respectively. The effects of the experimental parameters, including the sample pH, eluent type, interference ions and breakthrough volume, were studied for separation and preconcentration of Cu(II), Ni(II), Co(II) and Mn(II) ions. Determination of these ions in standard samples confirmed that the proposed method has good accuracy. The proposed method was used for the determination of these ions in water samples.  相似文献   
8.
A rapid method for the extraction and monitoring of nanogram level of Pb2+ and Cu2+ ions using uniform silanized mesopor (SBA-15) functionalized with aminobenzenesulfonamide groups and flame atomic absorption spectrometry (FAAS) is presented. Aminobenzenesulfonamide functionalized SBA-15 was synthesized according to procedure in the literature and the presence of organic groups in the silica framework was demonstrated by FT-IR spectra. The functionalized product showed the BET surface area 110 m2/g and pore diameter 5.1 nm, based on adsorption-desorption of N2 at 77 K. The effect of several variables such as (amount of adsorbent, stirring time, pH and presence of other ions in the medium) has been studied. Lead and copper were completely extracted at pH greater than 3 after stirring for 10 min. The maximum capacity of the adsorbent was found to be 191.3 ± 1.4 and 155.0 ± 1.0 μg of lead and copper ions/mg functionalized SBA-15, respectively. The preconcentration factor of the method was found to be 200. The detection limit of the technique was 3.4 and 0.4 ng/mL for Pb2+ and Cu2+, respectively. The applications of this methodology for real samples were examined by various water type, black tea and pepper samples.  相似文献   
9.
10.
Magnetic core–shell nanoparticles modified by (3-aminopropyl) trimethoxy silane were prepared and used as adsorbent for the extraction and preconcentration of cadmium and copper ions. The ions were desorbed with nitric acid followed by determination with flame atomic absorption spectrometry. The extraction conditions were investigated systematically. The method was applied for the determination of Cd(II) and Cu(II) ions in different water samples. The accuracy was also evaluated through analysis of certified reference material.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号