首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   22篇
  免费   0篇
  国内免费   1篇
环保管理   3篇
综合类   1篇
基础理论   2篇
污染及防治   1篇
评价与监测   8篇
社会与环境   8篇
  2019年   1篇
  2010年   1篇
  2009年   3篇
  2008年   2篇
  2007年   3篇
  2006年   2篇
  2005年   2篇
  2003年   2篇
  1998年   2篇
  1997年   1篇
  1994年   1篇
  1989年   1篇
  1986年   1篇
  1984年   1篇
排序方式: 共有23条查询结果,搜索用时 62 毫秒
1.
Concerns over data quality have raised many questions related to sampling soils for volatile organic compounds (VOCs). This paper was prepared in response to some of these questions and concerns expressed by Remedial Project Managers (RPMs) and On-Scene Coordinators (OSCs). The following questions are frequently asked:
  1. Is there a specific device suggested for sampling soils for VOCs?
  2. Are there significant losses of VOCs when transferring a soil sample from a sampling device (e.g., split spoon) into the sample container?
  3. What is the best method for getting the sample from the split spoon (or other device) into the sample container?
  4. Are there smaller devices such as subcore samplers available for collecting aliquots from the larger core and efficiently transferring the sample into the sample container?
  5. Are certain containers better than others for shipping and storing soil samples for VOC analysis?
  6. Are there any reliable preservation procedures for reducing VOC losses from soil samples and for extending holding times?
Guidance is provided for selecting the most effective sampling device for collecting samples from soil matrices. The techniques for sample collection, sample handling, containerizing, shipment, and storage described in this paper reduce VOC losses and generally provide more representative samples for volatile organic analyses (VOA) than techniques in current use. For a discussion on the proper use of sampling equipment the reader should refer to other sources (Acker, 1974; U.S. EPA, 1983; U.S. EPA, 1986a). Soil, as referred to in this report, encompasses the mass (surface and subsurface) of unconsolidated mantle of weathered rock and loose material lying above solid rock. Further, a distinction must be made as to what fraction of the unconsolidated material is soil and what fraction is not. The soil component here is defined as all mineral and naturally occurring organic material that is 2 mm or less in size. This is the size normally used to differentiate between soils (consisting of sands, silts, and clays) and gravels. Although numerous sampling situations may be encountered, this paper focuses on three broad categories of sites that might be sampled for VOCs:
  1. Open test pit or trench.
  2. Surface soils (<5 ft in depth).
  3. Subsurface soils (>5 ft in depth).
  相似文献   
2.
McMurdo Station is the largest research station in Antarctica, with a population that ranges each year from 250 to 1200 people. Because of its size and 40-year history of use, a number of locations around the station have become contaminated with wastes. Soils and sediments in these areas have been shown to contain elevated levels of petroleum-related products, PCBs, other organics, and metals. While some remedial investigations have been conducted, background levels of metals in soils have not been determined. This paper reports on background levels of metals in a natural basalt-derived soil (gray soil) and scoria (soft porous rock used as fill, red soil) near McMurdo Station using two fundamentally different analytical procedures, concentrated acid extraction/analysis and total metals. These data facilitate determining the extent and levels of metal contamination near McMurdo Station and provide reference levels of metals for comparison with existing and future remediation data. There were statistically significant differences between metals concentrations in both gray and red soils, and no correlations between the level of extracted versus total metal. Generally, only a small fraction of a metal was extractable.  相似文献   
3.
Environmental radon exposure of residents of domestic premises in the United Kingdom (UK) and elsewhere in Europe is estimated on the basis of the measured radon concentrations in, and the relative occupancies of, the principal living room and bedroom. While studies on radon concentration variability in the individual units in apartment blocks in various countries have been described, little data has been reported on variability in two-storey single-family dwellings, and the majority of extant studies consolidate living room and bedroom data early in the analysis. To investigate this further, detailed analysis was made of radon concentration data from a set of thirty-four homes situated in areas of Northamptonshire known to exhibit high radon levels. All homes were of typical UK construction of brick/block/stone walls under a pitched tile/slate roof. Approximately 50% of the sample were detached houses, the remainder being semi-detached (duplex) or terraced (row-house). Around 25% of the sample possessed cellars, while 12% were single-storey dwellings (bungalows), reflecting the typical incidence of this type of dwelling in England. In the two-storey homes, all monitored bedrooms were on the upper floor. Distribution of the ratios of bedroom/living room radon concentrations (BR/LR ratio) in individual properties was left-skewed (mean 0.67, median 0.73, range 0.05-1.05) with a tail extending to just above 1.0. The mean is consistent with the outcome of earlier extensive studies in England, while the variability depends principally on the characteristics of the property, and not on seasonal factors. In a small set of homes, the BR/LR ratio was anomalously low, (mean 0.3). BR/LR ratios in single-storey homes clustered around a value of 1.0, indicating that house design, rather than lifestyle, is the dominant factor in determining bedroom radon concentrations. Homes with higher mean annual radon concentrations showed lower BR/LR ratios, supporting our proposal that, in some homes, radon emanation from building materials may comprise a significant component of the overall radon level.  相似文献   
4.
Following an intensive survey of domestic radon levels in the United Kingdom (UK), the former National Radiological Protection Board (NRPB), now the Radiation Protection Division of the Health Protection Agency (HPA-RPD), established a measurement protocol and promulgated Seasonal Correction Factors applicable to the country as a whole. Radon levels in the domestic built environment are assumed to vary systematically and repeatably during the year, being generally higher in winter. The Seasonal Correction Factors therefore comprise a series of numerical multipliers, which convert a 1-month or 3-month radon concentration measurement, commencing in any month of the year, to an effective annual mean radon concentration. In a recent project undertaken to assess the utility of short-term exposures in quantifying domestic radon levels, a comparative assessment of a number of integrating detector types was undertaken, with radon levels in 34 houses on common geology monitored over a 12-month period using dose-integrating track-etch detectors exposed in pairs (one upstairs, one downstairs) at 1-month and 3-month resolution. Seasonal variability of radon concentrations departed significantly from that expected on the basis of the HPA-RPD Seasonal Correction Factor set, with year-end discontinuities at both 1-month and 3-month measurement resolutions. Following this study, monitoring with electrets was continued in four properties, with weekly radon concentration data now available for a total duration in excess of three and a half years. Analysis of this data has permitted the derivation of reliable local Seasonal Correction Factors. Overall, these are significantly lower than those recommended by HPA-RPD, but are comparable with other results from the UK and from abroad, particularly those that recognise geological diversity and are consequently prepared on a regional rather than a national basis. This finding calls into question the validity of using nationally aggregated Seasonal Correction Factors, especially for shorter exposures, and the universal applicability of these corrections is discussed in detail.  相似文献   
5.
Contamination of aquatic ecosystems with heavy metals has been receiving increased worldwide attention due to their harmful e ects on human health and other organisms in the environment. Most of the studies dealing with toxic e ects of metals deal with single metal species, while the aquatic organisms are typically exposed to mixtures of metals. Hence, in order to provide data supporting the usefulness of freshwater fish as indicators of heavy metal pollution, it has been proposed in the present study to investigate the bioaccumulation and depuration of chromium in the selected organs of freshwater fingerlings Cirrhinus mrigala, individually and in binary solutions with nickel. The results show that the kidney is a target organ for chromium accumulation, which implies that it is also the “critical” organ for toxic symptoms. The results further show that accumulation of nickel in all the tissues of C. mrigala is higher than that of chromium. In addition, the metal accumulations of the binary mixtures of chromium and nickel are substantially higher than those of the individual metals, indicating synergistic interactions between the two metals. Theoretically the simplest explanation for an additive joint action of toxicants in a mixture is that they act in a qualitatively similar way. The observed data suggest that C. mrigala could be suitable monitoring organisms to study the bioavailability of water-bound metals in freshwater habitats.  相似文献   
6.
Application of appropriate environmentally conscious manufacturing strategies enables the sustainable development of products and processes. Automotive component manufacturers recognise the potential of applying appropriate strategies for attaining Triple Bottom Line benefits. In this context, three strategies such as eco-efficiency, waste minimisation and material efficiency are being applied to minimise environmental impacts associated with the manufacture of automotive products and its associated processes. A case study of an automotive component manufacturing firm has been exemplified. After conducting the study, the potential environmental impact was reduced by 20% and eco-efficiency was improved by 13%. Further, improvements have been observed in terms of overall resource consumption and material efficiency. The overall power consumption was reduced by 18% and weight of the component was reduced by 11%. The study aimed at improving the sustainable performance of product by incorporating green and environmentally friendlier manufacturing practices.

Abbreviations: USEPA: United Nations Environmental Protection Agency; OECD: Organisation for Economic Co-operation and Development; WBCSD: World Business Council for Sustainable Development; Eco-QFD: Environmental Quality Function Deployment; WCED: World Commission on Environment and Development; LCA: Life Cycle Assessment  相似文献   

7.
Radon gas occurs naturally in the environment with variable distribution, concentrating sufficiently in the built environment in some areas to pose a public health risk. Radon levels can be successfully reduced in affected buildings, and large-scale remediation programmes have been justified in terms of accrued costs and benefits. We present results from a house where radon levels in the main living-room and master bedroom were monitored on an hourly basis over extended periods before and after radon remediation by sub-slab depressurisation. These results were combined with results from a recent occupancy survey to estimate the health impact on occupants spending varying times in the home. Prior to remediation, mean hourly radon exposure is moderately linearly correlated (R(2)=0.66-0.78) with time spent in the house. Following remediation, correlation is significantly enhanced (R(2)=0.91-0.95), but the exposure reduction of an occupant following remediation is less than that predicted using the NRPB protocol.  相似文献   
8.
Radon gas occurs naturally in the environment with a variable distribution. In some areas radon concentrates sufficiently within the built environment that it is considered as a public health risk. It is possible, successfully, to reduce radon levels in the built environment, and it has been shown that such remediation programmes can be justified in terms of the costs and benefits accruing. However, the estimated dose received by people in their homes depends on the time spent indoors. The research presented here uses data derived from time activity surveys in Northamptonshire, together with radon data from a representative home, to model potential exposures for different population sub-groups. Average home occupancy ranged from 14.8h (probable error 2.5h) for students to 17.7 (3.1) h for adults; schoolchildren spent an average of 14.9 (1.2) h at home. Over a quarter of adults, however, were in the home for 22 h on more. These differences in occupancy patterns lead to substantial differences in radon exposure. In a home with an average hourly ground floor radon concentration of 467 Bqm(-3), modelled hourly average exposures ranged from ca. 250 Bqm(-3) for students and school children, to over 340 Bqm(-3), for women based at home. Modelled exposures show a non-linear association with total time spent at home, suggesting that exposure estimates based on linear models may provide misleading estimates of health risks from radon and the potential benefits of radon remediation. Highest hourly exposures are likely to be experienced by people with highly occupancy, living in single-storey, ground floor accommodation (for example, the elderly the infirm and non-working young mothers). Since these may be least aware of radon risks, and least able to take up remediation measures, they should be specifically targeted for radon monitoring and for assistance in remediation schemes.  相似文献   
9.
Lead is a widespread element and one of the persistent and cumulative pollutants of the environment. The present study deals with the bioaccumulation of lead and the influence of chelating agents, meso 2,3-dimercaptosuccinic acid (DMSA), D-Penicillamine and CaNa2EDTA in reducing the concentration of lead on the selected organs of Catla catla fingerlings for both acute and chronic exposures by using ICP-AES. It is inferred from the present findings that there was a correlation between environmental conditions and the heavy metal contents of the fish. The highest concentration of lead is found in kidney tissues and the lowest in muscle tissues. The accumulation pattern of lead in the selected organs of Catla catla is: kidney > liver > gill > brain > muscle. Also, it has been found that the treatment of chelating agents, DMSA, D-Penicillamine and CaNa2EDTA reduces the concentration of lead significantly for both acute and chronic exposures. The results also show that DMSA is the most effective chelator of lead in reducing the body burden of C. catla fingerlings. The observed data further indicate that C. catla could be suitable for monitoring organisms to study the bioavailability of water-bound metals in freshwater habitats.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏