全文获取类型
收费全文 | 62篇 |
免费 | 1篇 |
国内免费 | 1篇 |
专业分类
安全科学 | 3篇 |
废物处理 | 1篇 |
环保管理 | 12篇 |
综合类 | 3篇 |
基础理论 | 17篇 |
污染及防治 | 22篇 |
评价与监测 | 3篇 |
社会与环境 | 3篇 |
出版年
2021年 | 2篇 |
2018年 | 1篇 |
2017年 | 1篇 |
2016年 | 5篇 |
2015年 | 3篇 |
2014年 | 1篇 |
2013年 | 5篇 |
2012年 | 2篇 |
2011年 | 6篇 |
2010年 | 2篇 |
2009年 | 3篇 |
2008年 | 4篇 |
2007年 | 6篇 |
2006年 | 2篇 |
2005年 | 3篇 |
2004年 | 3篇 |
2003年 | 3篇 |
2002年 | 2篇 |
2001年 | 1篇 |
2000年 | 1篇 |
1997年 | 1篇 |
1994年 | 2篇 |
1993年 | 1篇 |
1992年 | 1篇 |
1984年 | 1篇 |
1977年 | 1篇 |
1970年 | 1篇 |
排序方式: 共有64条查询结果,搜索用时 15 毫秒
1.
L.J. Deacon L.J. Pankhurst G.H. Drew E.T. Hayes S. Jackson P.J. Longhurst J.W.S. Longhurst J. Liu S.J.T. Pollard S.F. Tyrrel 《Atmospheric environment (Oxford, England : 1994)》2009,43(35):5698-5701
Information on the particle size distribution of bioaerosols emitted from open air composting operations is valuable in evaluating potential health impacts and is a requirement for improved dispersion simulation modelling. The membrane filter method was used to study the particle size distribution of Aspergillus fumigatus spores in air 50 m downwind of a green waste compost screening operation at a commercial facility. The highest concentrations (approximately 8 × 104 CFU m−3) of culturable spores were found on filters with pore diameters in the range 1–2 μm which suggests that the majority of spores are emitted as single cells. The findings were compared to published data collected using an Andersen sampler. Results were significantly correlated (p < 0.01) indicating that the two methods are directly comparable across all particles sizes for Aspergillus spores. 相似文献
2.
3.
Integrated Resource Management: Moving from Rhetoric to Practice in Australian Agriculture 总被引:1,自引:0,他引:1
/ Implementing the concept of sustainability through integrated approaches to natural resource management poses enormous challenges for both the rural communities and government agencies concerned. This paper reviews the underlying rhetoric of sustainable agricultural systems and the integrated resource management paradigm and identifies some of the challenges being experienced in translating this rhetoric into practice. A relatively recently implemented community-based integrated catchment management (ICM) process in a rural community in northeast Australia is examined in terms of some of the lessons learned that may be relevant to other similar integrated resource management (IRM) processes. It reveals a pragmatic, opportunistic, and evolving implementation process based on adaptive learning rather than a more traditional "rational" planning approach. Some essential characteristics of a community-based IRM process are identified, including fostering communication; providing a structure that fosters cooperation and facilities coordination among community, industry, and government agencies; the integration of IRM principles into local government planning schemes; and an emergent strategic approach to IRM program implementation. We conclude by identifying some essential characteristics of an IRM process that can assist a community to adapt to, and manage change for, sustainable resource use. 相似文献
4.
5.
Thermal requirements to protect aquatic life in texas reservoirs 总被引:1,自引:0,他引:1
6.
I-Risk: development of an integrated technical and management risk methodology for chemical installations 总被引:1,自引:0,他引:1
I. A. Papazoglou L. J. Bellamy A. R. Hale O. N. Aneziris B. J. M. Ale J. G. Post J. I. H. Oh 《Journal of Loss Prevention in the Process Industries》2003,16(6):575-591
This paper presents an integrated quantitative risk assessment method for hazardous installations, taking into account management as well as technical design and producing risk level measures. The key components of the I-Risk methodology are the technical model, the management model and their interface. The technical model consists of developing a master logic diagram (MLD) delineating the major immediate causes of loss of containment (LOC) and associated quantitative models for assessing their frequency. The management model consists of the tasks, which must be carried out systematically in the primary business functions (such as operations, emergency operations, maintenance and modifications). A management audit quantifies the quality of these management tasks. The management–technical interface modifies certain parameters of the technical model on the basis of the quality of the safety management system of the specific installation. The methodology is exemplified through its application to the risk assessment of an ammonia storage facility. A detailed technical model simulating the response of the system to various initiating events is developed along with a detailed management model simulating the influence of the plant-specific management and organisational practices. The overall effect is quantified through the frequency of release of ammonia as a result of a loss of containment in a storage tank and in a pipeline. 相似文献
7.
8.
Kijune Sung Jaisoo Kim C.L. Munster M. Yavuz Corapcioglu Soyoung Park M.C. Drew Y.Y. Chang 《Ecological modelling》2006,190(3-4):277-286
Microorganisms make an important contribution to the degradation of contaminants in bioremediation as well as in phytoremediation. An accurate estimation of microbial concentrations in the soil would be valuable in predicting contaminant dissipation during various bioremediation processes. A simple modeling approach to quantify the microbial biomass in the rhizosphere was developed in this study. Experiments were conducted using field column lysimeters planted with Eastern gamagrass. The microbial biomass concentrations from the rhizosphere soil, bulk soil, and unplanted soil were monitored for six months using an incubation–fumigation method. The proposed model was applied to the field microbial biomass data and good correlation between simulated and experimental data was achieved. The results indicate that plants increase microbial concentrations in the soil by providing root exudates as growth substrates for microorganisms. Since plant roots are initially small and do not produce large quantities of exudates when first seeded, the addition of exogenous substrates may be needed to increase initial microbial concentrations at the start of phytoremediation projects. 相似文献
9.
Dyer SD Peng C McAvoy DC Fendinger NJ Masscheleyn P Castillo LV Lim JM 《Chemosphere》2003,52(1):43-53
A risk assessment of chemical constituents in rivers that receive untreated wastewater should take into account the adverse effects of increased biological oxygen demand (BOD), ammonia and reduced dissolved oxygen (DO). This concept was tested via a field study in the Balatuin River, The Philippines, where the influence of physical and chemical factors, including the consumer product chemical linear alkylbenezene sulfonate (LAS), to aquatic communities (algae, invertebrates, fish) was determined. Periphytic algae were found to be insensitive to high BOD (>10 mg/l) and ammonia (>0.01 mg unionized NH(3)/l), concentrations from organically enriched untreated wastewater discharges. However, taxa richness and abundance of macroinvertebrates were influenced greatly by the discharges. Where BOD and ammonia concentrations were elevated, the dominant taxa were oligochaete worms and chironominds. Fish and crustaceans (freshwater crabs and prawns) were found only in sites with the least BOD concentrations (furthest upstream and downstream). The maximum concentration of LAS (0.122 mg/l) was less than that expected to affect 5% of taxa (0.245 mg/l), whereas exceedences of DO and ammonia criteria were observed in several sites. The lack of recovery observed was attributed to influences of low DO, high ammonia and poor colonization from upstream and downstream reaches due to organically-enriched discharges 相似文献
10.
Linda J. Bellamy Martijn Mud Henk Jan Manuel Joy I.H. Oh 《Journal of Loss Prevention in the Process Industries》2013,26(6):1039-1059
In the Netherlands there are around 400 “Seveso” sites that fall under the Dutch Major Hazards Decree (BRZO) 1999. Between 2006 and 2010 the Dutch Labour Inspectorate's Directorate for Major Hazard Control completed investigations of 118 loss of containment incidents involving hazardous substances from this group. On the basis of investigation reports the incidents were entered in a tailor-made tool called Storybuilder developed for the Dutch Ministry of Social Affairs and Employment for identifying the dominant patterns of technical safety barrier failures, barrier task failures and underlying management causes associated with the resulting loss of control events. The model is a bow-tie structure with six lines of defence, three on either side of the central loss of containment event. In the first line of defence, failures in the safety barriers leading to loss of control events were primarily equipment condition failures, pre start-up and safeguarding failures and process deviations such as pressure and flow failures. These deviations, which should have been recovered while still within the safe envelope of operation, were missed primarily because of inadequate indication signals that the deviations have occurred. Through failures of subsequent lines of defence they are developing into serious incidents. Overall, task failures are principally failures to provide adequate technical safety barriers and failures to operate provided barriers appropriately. Underlying management delivery failures were mainly found in equipment specifications and provisions, procedures and competence. The competence delivery system is especially important for identifying equipment condition, equipment isolation for maintenance, pre-start-up status and process deviations. Human errors associated with operating barriers were identified in fifty per cent of cases, were mostly mistakes and feature primarily in failure to prevent deviations and subsequently recover them. Loss of control associated with loss of containment was primarily due to the containment being bypassed (72% of incidents) and less to material strength failures (28%). Transfer pipework, connections in process plant and relief valves are the most frequent release points and the dominant release material is extremely flammable. It is concluded that the analysis of a large number of incidents in Storybuilder can support the quantification of underlying causes and provide evidence of where the weak points exist in major hazard control in the prevention of major accidents. 相似文献