首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   14篇
  免费   0篇
  国内免费   1篇
废物处理   5篇
综合类   1篇
污染及防治   8篇
评价与监测   1篇
  2022年   1篇
  2019年   1篇
  2018年   1篇
  2015年   1篇
  2014年   3篇
  2013年   1篇
  2012年   1篇
  2011年   1篇
  2010年   1篇
  2009年   1篇
  2008年   1篇
  2007年   1篇
  2003年   1篇
排序方式: 共有15条查询结果,搜索用时 15 毫秒
1.
Remediation and recovery efforts after a release of Bacillus anthracis (anthrax) spores may be difficult and costly. In addition, response and recovery technologies may be focused on critical resources, leaving the small business or homeowner without remediation options. This study evaluates the efficacy of relatively low levels of hydrogen peroxide vapor (HPV) delivered from off‐the‐shelf equipment for the inactivation of Bacillus spores within an indoor environment. Decontamination evaluations were conducted in a house using both Bacillus atrophaeus var. globigii (Bg; as surrogates for B. anthracis) inoculated on the carpet and galvanized metal as coupons and Geobacillus stearothermophilus (Gs) as biological indicators on steel. The total decontamination time ranged from 4 to 7 days. Using the longer exposure times, low concentrations of HPV (average levels below 20 parts per million) effectively inactivated Bg and Gs spores on the materials tested. The HPV was generated with commercial humidifiers and household‐strength hydrogen peroxide solutions. The presence of home furnishings did not have a significant impact on HPV efficacy. This simple, inexpensive, and effective decontamination method could have significant utility for remediation following a B. anthracis spore release, such as following a terrorist attack.  相似文献   
2.
Environmental Science and Pollution Research - Drinking water treatment sludge (DWTS) generated from water treatment plants is a global issue because of the environmental risks it imposes. Managing...  相似文献   
3.
Four types of undisturbed soil in Ain Oussera region around the Es-Salam reactor facility, located in the south of Algiers, Algeria, at about 200 km, were artificially contaminated for one year with stable CsCl and SrCl2 in order to simulate an accidental release of these elements. This study was performed using sequential extraction procedure based on Shultz method and containing six fractions. The selectivity of the extraction protocol was confirmed by analyzing some elements (Ca, C, Fe, Mn, Si and Al) designed as indicators of the targeted phases. The obtained results showed an acceptable reproducibility, in view of the coefficients of variation that were in most cases less than 15%. The results revealed a clear proportional correlation between the extracted Cs and Sr in fractions for each soil and some of soils physicochemical properties. Organic matter appears to play an important role in the soil retention, particularly for Cs where the extracted percentage exceeds to 30% in whole soils. In contrast, strontium expresses a remarkable affinity for the fraction bound to carbonates. The obtained data also indicate that the availability of Cs in the four soils is less important compared to Sr availability. This is illustrated by the higher value of extracted Sr in the easily extractible phase, including the water-soluble and the exchangeable fraction.  相似文献   
4.
A survey of the epiphytic leaves of Posidonia oceanica was conducted along a depth transect at both the control station Attaya in the Kerkennah Islands and the disturbed Mahres station on the Sfax coast (Tunisia). Samples were collected by scuba divers at depths of 5, 10, 15, and 20 m in July 2008. We evaluated whether the pattern of spatial variability of the macroepiphyte assemblages of leaves of Posidonia oceanica differed in relation to anthropogenic interference. The results indicate that the decrease in shoot density and leaf length according to depth was low at Mahres. The biomass of epiphytic leaves and the percentage cover of epiphytic assemblages decreased with depth for both stations and heavily at Mahres, this decline being related to anthropogenic disturbance. This study shows that the highest values of epifauna and epiflora were detected at the disturbed station Mahres. Macroalgae assemblages decreased with depth at both stations and were dominated by Rhodophyta, whereas the percentage cover of the epifauna leaf that decreases according to depth was dominated by Hydrozoa and Bryozoa. Changes in epiphyte assemblages, epiphytic biomass, percentage cover, and species richness in proportion to Heterokontophyta, Rhodophyta, Cyanobacteria, Hydrozoa, Porifera, and Tunicata between the two stations constitute promising tools for detecting environmental disturbance.  相似文献   
5.
The cleaning robots, a vacuum‐based robot (R2) and a wetted‐wipe‐based robot (R4), were evaluated in this study to determine their effectiveness for sampling Bacillus atrophaeus spores. The tests were designed to evaluate the benefit of robot sampling on large areas with two different contamination scenarios: a high‐concentration, low spatial extent contamination (hot spot) and a low concentration, high spatial extent contamination (widely dispersed). The hot spot tests were conducted with the high spore contamination (approximately 107 colony forming units [CFUs]) on a limited area (30.5 cm × 30.5 cm), 2 percent of the entire test. The widely dispersed tests were conducted with approximately 0.1 CFUs/cm2 for floor laminate and approximately 10 CFUs/cm2 for carpet surfaces. The widely dispersed tests distributed spores across the test surface and covered approximately 40 percent of the entire test area. The test results showed that both robots successfully sampled a large quantity of spores from carpet and floor laminate surfaces for both test scenarios. Robot performance is discussed in the context of currently used surface sampling methods. © 2014 Wiley Periodicals, Inc.*  相似文献   
6.
Air emissions and residual ash samples were collected and analyzed during experiments of open, uncontrolled combustion of electronic waste (e-waste), simulating practices associated with rudimentary e-waste recycling operations. Circuit boards and insulated wires were handled separately to simulate processes associated with metal recovery. The average emissions of polychlorinated dibenzodioxins and dibenzofurans (PCDD/PCDFs) were 92 ng toxic equivalency (TEQ)/kg [n = 2, relative standard deviation (RSD) = 98%] and 11 900 ng TEQ/kg (n = 3, RSD = 50%) of the initial mass of the circuit boards and insulated wire, respectively. The value for the insulated wire is about 100 times higher than that for backyard barrel burning of domestic waste. The emission concentrations of polybrominated dibenzodioxins and dibenzofurans (PBDD/PBDFs) from the combustion of circuit boards were 100 times higher than for their polychlorinated counterparts. Particulate matter (PM) sampling of the fly ash emissions indicated PM emission factors of approximately 15 and 17 g/kg of the initial mass for the circuit boards and insulated wire, respectively. Fly ash samples from both types of e-waste contained considerable amounts of several metallic elements and halogens; lead concentrations were more than 200 times the United States regulatory limits for municipal waste combustors and 20 times those for secondary lead smelters. Leaching tests of the residual bottom ash showed that lead concentrations exceeded U.S. Environmental Protection Agency landfill limits, designating this ash as a hazardous waste.  相似文献   
7.
Both long duration (>6 h) and high temperature (up to 139 °C) sampling efforts were conducted using ambient air sampling methods to determine if either high volume throughput or higher than ambient air sampling temperatures resulted in loss of target polychlorinated dibenzodioxins/dibenzofurans (PCDDs/PCDFs) from a polyurethane foam (PUF) sorbent. Emissions from open burning of simulated military forward operating base waste were sampled using EPA Method TO-9A for 185 min duration using a filter/PUF/PUF in series combination. After a 54 m3 sample was collected, the sampler was removed from the combustion source and the second PUF was replaced with a fresh, clean PUF. An additional 6 h of ambient air sampling (171 m3) was conducted and the second PUF was analyzed to determine if the PCDD/PCDF transferred from the filter and the first PUF. Less than 4.4% of the initial PCDD/PCDF was lost to the second PUF. To assess the potential for blow off of PCDD/PCDF analytes during open air sampling, the mobility of spiked mono- to hepta-PCDD/PCDF standards across a PUF sorbent was evaluated from ambient air temperatures to 145 °C with total volumes between 600 L and 2400 L. Lower molecular weight compounds and higher flow amounts increased release of the spiked standards consistent with vapor pressure values. At 600 L total sampled volume, the release temperature for 1% of the tetra-CDD (the lowest chlorinated homologue with a toxic compound) was 87 °C; increasing the volume fourfold reduced this temperature to 73 °C.  相似文献   
8.
The effect of the injection of brominated powdered activated carbon (Br-PAC) on the emission of brominated and chlorinated dioxins and furans in coal combustion flue gas has been evaluated. The sampling campaigns were performed at two U.S. Department of Energy (DOE) demonstration sites where brominated PAC was being injected for control of mercury emissions. The results of the sampling campaigns showed that injection of the brominated PAC upstream of the electrostatic precipitator (ESP) did not increase the emissions of total and Toxic EQuivalent (TEQ) chlorinated and brominated dioxin compounds. Rather, the data suggested the sorbent may capture these compounds and reduce their concentration in the flue gas stream. This effect, when seen, was small, and independent of the type of plant emission controls, temperature at the point of injection, or fuel-chlorine content. The addition of the brominated PAC sorbent resulted in slight increases the total content of chlorinated dioxins and furan in the particulate matter (ash) collected in the ESP, but did not increase its overall toxicity.  相似文献   
9.
The toxic equivalency (TEQ) values of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) are predicted with a model based on the homologue concentrations measured from a laboratory-scale reactor (124 data points), a package boiler (61 data points), and operating municipal waste incinerators (114 data points). Regardless of the three scales and types of equipment, the different temperature profiles, sampling emissions and/or solids (fly ash), and the various chemical and physical properties of the fuels, all the PCDF plots showed highly linear correlations (R(2)>0.99). The fitting lines of the reactor and the boiler data were almost linear with slope of unity, whereas the slope of the municipal waste incinerator data was 0.86, which is caused by higher predicted values for samples with high measured TEQ. The strong correlation also implies that each of the 10 toxic PCDF congeners has a constant concentration relative to its respective total homologue concentration despite a wide range of facility types and combustion conditions. The PCDD plots showed significant scatter and poor linearity, which implies that the relative concentration of PCDD TEQ congeners is more sensitive to variations in reaction conditions than that of the PCDF congeners.  相似文献   
10.
Open burning for waste disposal is, in many countries, the dominant source of polychlorinated dibenzodioxins, dibenzofurans and biphenyls (PCDD/PCDF/PCB) release to the environment. To generate emission factors for open burning, experimental pile burns of about 100 kg of household waste were conducted with emissions sampling. From these experiments and others conducted by the same authors it is found that less compaction of waste or active mixing during the fire - “stirring” - promotes better combustion (as evidenced by lower CO/CO2 ratio) and reduces emissions of PCDD/PCDF/PCB; an intuitive but previously undemonstrated result. These experiments also support previous results suggesting PCDD/PCDF/PCB generation in open burning - while still highly variable - tends to be greater in the later (smoldering) phases of burning when the CO/CO2 ratio increases.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号