首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   27篇
  免费   1篇
安全科学   2篇
废物处理   1篇
环保管理   3篇
综合类   7篇
基础理论   3篇
污染及防治   11篇
评价与监测   1篇
  2023年   1篇
  2022年   1篇
  2021年   2篇
  2019年   1篇
  2018年   1篇
  2017年   1篇
  2016年   5篇
  2015年   1篇
  2013年   3篇
  2012年   3篇
  2010年   1篇
  2008年   1篇
  2006年   2篇
  2002年   1篇
  1983年   1篇
  1960年   1篇
  1959年   1篇
  1957年   1篇
排序方式: 共有28条查询结果,搜索用时 15 毫秒
1.
The paper presents the adsorption of Remazol brilliant blue (RBB) and Disperse orange 25 (DO25) dyes from aqueous solution of the mixture of dyes onto concentrated sulphuric acid-treated red mud (ATRM). First-order derivative spectrophotometric method was developed for the analysis of RBB and DO25 in mixed dye aqueous solution to overcome the limitations arising due to interference in the zero-order spectral method. The optimum conditions to maximize RBB adsorption favoured the adsorption of RBB, and those for DO25 favoured DO25 adsorption from the mixed dye aqueous solutions. Presence of a second dye always inhibited the adsorption of a target dye. The uptake and percentage adsorption of each of the dyes onto ATRM from the aqueous solution of the mixture of dyes decreased considerably with increasing concentrations of the other dye showing the antagonistic effect. Monocomponent Langmuir isotherm fitted the mixed dye adsorption equilibrium data better than the monocomponent Freundlich isotherm. However, monocomponent models are suitable for the fixed concentration of the other dye. Modified Langmuir isotherm model adequately predicted the multi-component adsorption equilibrium data for RBB-DO25-ATRM adsorption system with a good accuracy and is more generic from the application point of view.  相似文献   
2.
Subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, in this study, a new cumulative calculation method for the estimation of total amounts of indoor air pollutants emitted inside the subway station is proposed by taking cumulative amounts of indoor air pollutants based on integration concept. Minimum concentration of individual air pollutants which naturally exist in indoor space is referred as base concentration of air pollutants and can be found from the data collected. After subtracting the value of base concentration from data point of each data set of indoor air pollutant, the primary quantity of emitted air pollutant is calculated. After integration is carried out with these values, adding the base concentration to the integration quantity gives the total amount of indoor air pollutant emitted. Moreover, the values of new index for cumulative indoor air quality obtained for 1 day are calculated using the values of cumulative air quality index (CAI). Cumulative comprehensive indoor air quality index (CCIAI) is also proposed to compare the values of cumulative concentrations of indoor air pollutants. From the results, it is clear that the cumulative assessment approach of indoor air quality (IAQ) is useful for monitoring the values of total amounts of indoor air pollutants emitted, in case of exposure to indoor air pollutants for a long time. Also, the values of CCIAI are influenced more by the values of concentration of NO2, which is released due to the use of air conditioners and combustion of the fuel. The results obtained in this study confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well.

Implications: Nowadays, subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in the indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, this paper presents a new methodology for monitoring and assessing total amounts of indoor air pollutants emitted inside underground spaces and subway stations. A new methodology for the calculation of cumulative amounts of indoor air pollutants based on integration concept is proposed. The results suggest that the cumulative assessment approach of IAQ is useful for monitoring the values of total amounts of indoor air pollutants, if indoor air pollutants accumulated for a long time, especially NO2 pollutants. The results obtained here confirm that the proposed method can be applied to monitor total amounts of indoor air pollutants emitted, inside apartments and hospitals as well.  相似文献   
3.
4.
5.
6.
We describe a new effort to enhance climate forecast relevance and usability through the development of a system for evaluating and displaying real‐time subseasonal to seasonal (S2S) climate forecasts on a watershed scale. Water managers may not use climate forecasts to their full potential due to perceived low skill, mismatched spatial and temporal resolutions, or lack of knowledge or tools to ingest data. Most forecasts are disseminated as large‐domain maps or gridded datasets and may be systematically biased relative to watershed climatologies. Forecasts presented on a watershed scale allow water managers to view forecasts for their specific basins, thereby increasing the usability and relevance of climate forecasts. This paper describes the formulation of S2S climate forecast products based on the Climate Forecast System version 2 (CFSv2) and the North American Multi‐Model Ensemble (NMME). Forecast products include bi‐weekly CFSv2 forecasts, and monthly and seasonal NMME forecasts. Precipitation and temperature forecasts are aggregated spatially to a United States Geological Survey (USGS) hydrologic unit code 4 (HUC‐4) watershed scale. Forecast verification reveals appreciable skill in the first two bi‐weekly periods (Weeks 1–2 and 2–3) from CFSv2, and usable skill in NMME Month 1 forecast with varying skills at longer lead times dependent on the season. Application of a bias‐correction technique (quantile mapping) eliminates forecast bias in the CFSv2 reforecasts, without adding significantly to correlation skill.  相似文献   
7.
8.

Energy and environmental issues have triggered the search for new sources of green energy alternatives in recent years. Biofuel production from renewable sources is widely considered one of the most sustainable alternatives for environmental and economic sustainability. Microalgae are currently being promoted as one of the most promising liquid biofuel feedstocks due to their rapid growth, high lipid production capacity, and carbon–neutral cycle. In this study, whole microalgae cells were utilized as raw material to produce solid biofuel, i.e., Bio-Coke, and this study aimed to investigate the possibility of microalgae Bio-Coke as an alternative to coal coke. The results show that Bio-Coke can be produced from microalgae in the temperature range of 80–100 °C. The apparent density is between 1.253 and 1.261 g/cm3, comparable to the apparent density of lignocellulosic Bio-Coke. Additionally, the calorific value is higher than the calorific value of lignocellulosic Bio-Coke and within the range of the calorific value of subbituminous coal. Therefore, microalgae Bio-Coke can be utilized to replace coal coke usage in the future.

  相似文献   
9.
Isolated sulfite oxidase deficiency is an autosomal recessive, neurological disorder resulting from a defect in SUOX, the gene encoding the enzyme that catalyzes the terminal reaction in the sulfur amino acid degradation pathway. In its classical, severe form, sulfite oxidase deficiency leads to intractable seizures, severe and progressive brain pathology and death at an early age. We report here on clinical features and mutational analysis of the genetic defect in a newborn with sulfite oxidase deficiency. Cultured fibroblasts from this patient exhibited no detectable sulfite oxidase activity, and a unique four base pair deletion was present in the cDNA isolated from the same source. Identification of the same genetic defect in a heterozygous state in each of the parents and the monitoring of subsequent pregnancies in this family by DNA-based prenatal diagnosis are also described. The deletion mutation was identified in a homozygous state in uncultured chorionic villus tissue from the second pregnancy that was subsequently terminated. In the third pregnancy, the presence of sulfite oxidase activity and identification of the mutation in a heterozygous state suggested that the fetus was not affected. This pregnancy resulted in the birth of a normal child. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号