全文获取类型
收费全文 | 129篇 |
免费 | 3篇 |
国内免费 | 11篇 |
专业分类
安全科学 | 4篇 |
废物处理 | 11篇 |
环保管理 | 15篇 |
综合类 | 32篇 |
基础理论 | 10篇 |
污染及防治 | 50篇 |
评价与监测 | 16篇 |
社会与环境 | 4篇 |
灾害及防治 | 1篇 |
出版年
2022年 | 2篇 |
2021年 | 2篇 |
2020年 | 2篇 |
2019年 | 3篇 |
2018年 | 1篇 |
2017年 | 7篇 |
2016年 | 11篇 |
2015年 | 7篇 |
2014年 | 8篇 |
2013年 | 11篇 |
2012年 | 11篇 |
2011年 | 10篇 |
2010年 | 5篇 |
2009年 | 8篇 |
2008年 | 5篇 |
2007年 | 16篇 |
2006年 | 7篇 |
2005年 | 7篇 |
2004年 | 10篇 |
2003年 | 6篇 |
2002年 | 3篇 |
2001年 | 1篇 |
排序方式: 共有143条查询结果,搜索用时 265 毫秒
1.
2.
Performance of an electrochemical COD (chemical oxygen demand) sensor with an electrode-surface grinding unit 总被引:2,自引:0,他引:2
Geun Jeong B Min Yoon S Ho Choi C Koang Kwon K Sik Hyun M Heui Yi D Soo Park H Kim M Joo Kim H 《Journal of environmental monitoring : JEM》2007,9(12):1352-1357
An electrochemical COD (chemical oxygen demand) sensor using an electrode-surface grinding unit was investigated. The electrolyzing (oxidizing) action of copper on an organic species was used as the basis of the COD measuring sensor. Using a simple three-electrode cell and a surface grinding unit, the organic species is activated by the catalytic action of copper and oxidized at a working electrode, poised at a positive potential. When synthetic wastewater was fed into the system, the measured Coulombic yields were found to be dependent on the COD of the synthetic wastewater. A linear correlation between the Coulombic yields and the COD of the synthetic wastewater was established (10-1000 mg L(-1)) when the electrode-surface grinding procedure was activated briefly at 8 h intervals. When various kinds of wastewater samples obtained from various sewage treatment plants were measured, linear correlations (r(2)> or = 0.92) between the measured EOD (electrochemical oxygen demand) value and COD of the samples were observed. At a practical wastewater treatment plant, the measurement system was successfully operated with high accuracy and good stability over 3 months. These experimental results show that the application of the measurement system would be a rapid and practical method for the determination of COD in water industries. 相似文献
3.
Jeong Kyungjun Hong Jiyeon Lee Yongjin Yang Jiyeon Lim Youngwook Shin Dongchun Kim Changsoo 《Environmental science and pollution research international》2021,28(28):37506-37519
Environmental Science and Pollution Research - Preschool children aged 3–6 years are vulnerable to exposed to particulate matter (“PM10” and “PM2.5”). It is required... 相似文献
4.
Jung Hwan Oh Eui-Jong Lee Jeong Ik Oh Jong-Oh Kim Am Jang 《Environmental science and pollution research international》2016,23(8):7074-7080
As cities are becoming increasingly aware of problems related to conventional mobile collection systems, automated pipeline-based vacuum collection (AVAC) systems have been introduced in some densely populated urban areas. The reasons are that in addition to cost savings, AVAC systems can be efficient, hygienic, and environmentally friendly. Despite difficulties in making direct comparisons of municipal waste between a conventional mobile collection system and an AVAC system, it is meaningful to measure the quantities in each of these collection methods either in total or on a per capita generation of waste (PCGW, g/(day*capita)) basis. Thus, the aim of this study was to assess the difference in per capita generation of household waste according to the different waste collection methods in Korea. Observations on household waste show that there were considerable differences according to waste collection methods. The value of per capita generation of food waste (PCGF) indicates that a person in a city using AVAC produces 60 % of PCGF (109.58 g/(day*capita)), on average, compared with that of a truck system (173.10 g/(day*capita)) as well as 23 %p less moisture component than that with trucks. The value of per capita generation of general waste (PCGG) in a city with an AVAC system showed 147.73 g/(day*capita), which is 20 % less than that with trucks delivered (185 g/(day*capita)). However, general waste sampled from AVAC showed a 35 %p increased moisture content versus truck delivery. 相似文献
5.
Enrichment of the metallic components from waste printed circuit boards by a mechanical separation process using a stamp mill 总被引:4,自引:0,他引:4
Printed circuit boards incorporated in most electrical and electronic equipment contain valuable metals such as Cu, Ni, Au, Ag, Pd, Fe, Sn, and Pb. In order to employ a hydrometallurgical route for the recycling of valuable metals from printed circuit boards, a mechanical pre-treatment step is needed. In this study, the metallic components from waste printed circuit boards have been enriched using a mechanical separation process. Waste printed circuit boards shredded to <10mm were milled using a stamp mill to liberate the various metallic components, and then the milled printed circuit boards were classified into fractions of <0.6, 0.6-1.2, 1.2-2.5, 2.5-5.0, and >5.0mm. The fractions of milled printed circuit boards of size <5.0mm were separated into a light fraction of mostly non-metallic components and a heavy fraction of the metallic components by gravity separation using a zig-zag classifier. The >5.0mm fraction and the heavy fraction were subjected to two-step magnetic separation. Through the first magnetic separation at 700 Gauss, 83% of the nickel and iron, based on the whole printed circuit boards, was recovered in the magnetic fraction, and 92% of the copper was recovered in the non-magnetic fraction. The cumulative recovery of nickel-iron concentrate was increased by a second magnetic separation at 3000 Gauss, but the grade of the concentrate decreased remarkably from 76% to 56%. The cumulative recovery of copper concentrate decreased, but the grade increased slightly from 71.6% to 75.4%. This study has demonstrated the feasibility of the mechanical separation process consisting of milling/size classification/gravity separation/two-step magnetic separation for enriching metallic components such as Cu, Ni, Al, and Fe from waste printed circuit boards. 相似文献
6.
We started the monitoring for PCDD/Fs in ambient air and soil in August 2001, and co-PCBs in January 2002. Decreasing of PCDD/Fs and co-PCBs levels in ambient air were observed. The higher PCDD/Fs levels were found in winter and lower in autumn. We found that the industrial incinerators influenced the PCDD/Fs levels in ambient air. In the 2,3,7,8-substituted PCDD/Fs concentration profiles, the three major congeners occupied 67% of the total mass. In case of co-PCBs, PCB#118, #105 and #77 were observed as the main congeners. Five cluster groups discriminated by ratio of four components, O(8)CDD, 1,2,3,4,6,7,8-H(7)CDD, 1,2,3,4,6,7,8-H(7)CDF and O(8)CDF, were obtained from HCA (hierarchical cluster analysis). 相似文献
7.
Gas-liquid phase partitioning is a key physical property that can predict the environmental fate of a compound between two phases. Several environmental factors have been known to affect the gas-liquid phase partitioning. We investigated the influence of surfactant on the gas-liquid phase partitioning of hydrogen peroxide (H(2)O(2)). The surfactant used was ammonium perfluorooctanoate (APFO). H(2)O(2) solution containing the surfactant was equilibrated in a closed system and gas phase H(2)O(2) concentration was measured by the peroxyoxalate chemiluminescence (PO-CL) method. Gas phase H(2)O(2) concentrations remained constant below the critical micelle concentration (CMC) and increased linearly with surfactant concentration above the CMC, which indicated that surfactant micelles influenced the gas-liquid phase partitioning of H(2)O(2). This result showed that H(2)O(2)-micelle interactions are less favorable than H(2)O(2)-H(2)O interactions. Surfactant monomers did not affect the gas-liquid phase partitioning of H(2)O(2) due to the absence of micelles. Solvent (methanol) effect was also investigated and showed that gas phase H(2)O(2) concentrations increased with the addition of solvent. This indicated the unfavorable interaction of H(2)O(2) with hydrophobic medium compared to hydrophilic one. It is consistent with the result that H(2)O(2)-micelles has a weaker interaction than H(2)O(2)-water because surfactant micelles are hydrocarbon-like organic phase rather than aqueous phase. 相似文献
8.
The removal of elemental mercury (Hg(0)) with the reactive species produced from dielectric barrier discharge (DBD) was studied. The effects of the operating parameters, such as the applied voltage, residence time, initial concentration and co-existence of other pollutants, were investigated. The removal of Hg(0) was significantly promoted by an increase in the applied voltage of the DBD reactor system. The presence of NO gas decreased the Hg(0) removal efficiency within the range of input powers tested compared to the case of Hg(0)-only due to the competition for ozone between Hg(0) and NO gas in the DBD reactor. 相似文献
9.
10.
Sung Ho Hwang Ik Mo Lee Yun Keun Lee Jeong Im Park Kwang Won Rhie Dong Uk Park Chung Sik Yoon 《Environmental monitoring and assessment》2013,185(11):8803-8808
We characterize the monthly variation in (1 → 3)-β-d-glucan concentration measured over the course of 1 year, and we evaluate the characteristics of size selection using a two-stage cyclone sampler. The (1 → 3)-β-d-glucan concentrations were measured in four bio-related laboratories. A total of 156 samples were collected using a new two-stage cyclone sampler. Analysis of (1 → 3)-β-d-glucan was performed using the kinetic Limulus amebocyte lysate assay. The study showed that airborne (1 → 3)-β-d-glucan concentrations were significantly higher in laboratory D (mean ± SD 1,105?±?1,893 pg/m3) and in the spring (5,458 pg/m3). The highest concentration of (1 → 3)-β-d-glucan occurred in the spring, particularly in May. 相似文献