全文获取类型
收费全文 | 179篇 |
免费 | 1篇 |
国内免费 | 5篇 |
专业分类
安全科学 | 8篇 |
废物处理 | 15篇 |
环保管理 | 22篇 |
综合类 | 22篇 |
基础理论 | 36篇 |
污染及防治 | 60篇 |
评价与监测 | 13篇 |
社会与环境 | 5篇 |
灾害及防治 | 4篇 |
出版年
2022年 | 3篇 |
2021年 | 5篇 |
2019年 | 2篇 |
2018年 | 10篇 |
2017年 | 3篇 |
2016年 | 7篇 |
2015年 | 1篇 |
2014年 | 8篇 |
2013年 | 23篇 |
2012年 | 17篇 |
2011年 | 18篇 |
2010年 | 5篇 |
2009年 | 10篇 |
2008年 | 17篇 |
2007年 | 15篇 |
2006年 | 10篇 |
2005年 | 11篇 |
2004年 | 7篇 |
2003年 | 3篇 |
2002年 | 4篇 |
2001年 | 2篇 |
2000年 | 1篇 |
1999年 | 1篇 |
1989年 | 1篇 |
1986年 | 1篇 |
排序方式: 共有185条查询结果,搜索用时 31 毫秒
1.
When combined in the lining and covering of waste-containment facilities, soil and geosynthetic components protect the environment by acting as a hydraulic barrier. Equipment loading may significantly increase the tensile stress induced in geosynthetic components, leading to a potential stability problem. Large equipment loadings may also result in a localized circular slip surface during construction operations. New analytical method based on discrete element modelling is proposed for estimating the distribution of tensile force developed in the individual geosynthetic components of the lining system and for evaluating the safety factor of slope failure due to equipment loading. The analytical results of an example are presented to demonstrate the applicability of the analytical method for the lining system of a waste landfill. The analyses of the example show that equipment loading provide a substantial increase in the tensile forces of the geosynthetic components of a lining system and that the possibility of shallow failure due to equipment loading increases as the slope becomes steeper. This method is a useful tool for analysing the lining system of waste landfills with complex lining components. 相似文献
2.
Repeated application may increase rates of pesticide dissipation in soil and reduce persistence. The potential for this to occur was investigated for the fungicide, tebuconazole (alpha-[2-(4-chlorophenyl)ethyl]-alpha-(1,1-dimethylethyl)-1H-1,2,4-triazole-1-ethanol), when used for peanut (Arachis hypogaea L.) production. Soil samples were collected from peanut plots after each of four tebuconazole applications at 2-wk intervals. Soil moisture was adjusted to field capacity as necessary and samples were incubated in the laboratory for 63 d at 30 degrees C. Untreated plot samples spiked with the compound served as controls. Results indicated accelerated dissipation in field-treated samples with the time to fifty percent dissipation (DT50) decreasing from 43 to 5 d after three tebuconazole applications. Corresponding increases in rates of accumulation and decay of degradates were also indicated. Best-fit equations (r2 = 0.84-0.98) to dissipation kinetic data combined with estimates of canopy interception rates were used to predict tebuconazole and degradates concentration in soil after each successive application. Predicted concentrations compared with values measured in surface soil samples were from twofold less to twofold greater. Use of kinetic data will likely enhance assessments of treatment efficacy and human and ecological risks from normal agronomic use of tebuconazole on peanut. However, the study indicated that varying soil conditions (in particular, soil temperature and water content) may have an equal or greater impact on field dissipation rate than development of accelerated dissipation. Results emphasize that extension of laboratory-derived kinetic data to field settings should be done with caution. 相似文献
3.
Daniel S. Read Marianne Matzke Hyun S. Gweon Lindsay K. Newbold Laura Heggelund Maria Diez Ortiz Elma Lahive David Spurgeon Claus Svendsen 《Environmental science and pollution research international》2016,23(5):4120-4128
Zinc oxide nanoparticles (ZnO NPs) are used in an array of products and processes, ranging from personal care products to antifouling paints, textiles, food additives, antibacterial agents and environmental remediation processes. Soils are an environment likely to be exposed to manmade nanoparticles due to the practice of applying sewage sludge as a fertiliser or as an organic soil improver. However, understanding on the interactions between soil properties, nanoparticles and the organisms that live within soil is lacking, especially with regards to soil bacterial communities. We studied the effects of nanoparticulate, non-nanoparticulate and ionic zinc (in the form of zinc chloride) on the composition of bacterial communities in soil with a modified pH range (from pH 4.5 to pH 7.2). We observed strong pH-dependent effects on the interaction between bacterial communities and all forms of zinc, with the largest changes in bacterial community composition occurring in soils with low and medium pH levels (pH 4.8 and 5.9). The high pH soil (pH 7.2) was less susceptible to the effects of zinc exposure. At the highest doses of zinc (2500 mg/kg dw soil), both nano and non-nano particulate zinc applications elicited a similar response in the soil bacterial community, and this differed significantly to the ionic zinc salt treatment. The results highlight the importance of considering soil pH in nanotoxicology studies, although further work is needed to determine the exact mechanisms controlling the toxicity and fate and interactions of nanoparticles with soil microbial communities. 相似文献
4.
We started the monitoring for PCDD/Fs in ambient air and soil in August 2001, and co-PCBs in January 2002. Decreasing of PCDD/Fs and co-PCBs levels in ambient air were observed. The higher PCDD/Fs levels were found in winter and lower in autumn. We found that the industrial incinerators influenced the PCDD/Fs levels in ambient air. In the 2,3,7,8-substituted PCDD/Fs concentration profiles, the three major congeners occupied 67% of the total mass. In case of co-PCBs, PCB#118, #105 and #77 were observed as the main congeners. Five cluster groups discriminated by ratio of four components, O(8)CDD, 1,2,3,4,6,7,8-H(7)CDD, 1,2,3,4,6,7,8-H(7)CDF and O(8)CDF, were obtained from HCA (hierarchical cluster analysis). 相似文献
5.
Junki Yun Ju Young Lee Jeehyeong Khim Won Hyun Ji 《Environmental monitoring and assessment》2013,185(8):6855-6865
The purpose of this study was to assess contaminated soil and groundwater for the urban redevelopment of a rapid transit railway and a new mega-shopping area. Contaminated soil and groundwater may interfere with the progress of this project, and residents and shoppers may be exposed to human health risks. The study area has been remediated after application of first remediation technologies. Of the entire area, several sites were still contaminated by waste materials and petroleum. For zinc (Zn) contamination, high Zn concentrations were detected because waste materials were disposed in the entire area. For petroleum contamination, high total petroleum hydrocarbon (TPH) and hydrocarbon degrading microbe concentrations were observed at the depth of 7 m because the underground petroleum storage tank had previously been located at this site. Correlation results suggest that TPH (soil) concentration is still related with TPH (groundwater) concentration. The relationship is taken into account in the Spearman coefficient (α). 相似文献
6.
Krishna Lal Chhetri Jae-Hyuk Hyun Goo-Hwang Jung 《Journal of Material Cycles and Waste Management》2018,20(4):1901-1908
Demand for sustainable renewable energy is on an increase worldwide, whereas the supply is limited. This paper analyses the feasibility of generating electricity and supplying the surplus steam to Daeduk Industrial Complex, by incinerating the combustible municipal waste generated in Daejeon Metropolitan City. The economic feasibility of surplus biogas generated from the anaerobic digestion of food waste and food waste leachate has been analysed. This study estimated resource circulation facility to supply 23,200 m3/day of biogas generated to Daejeon Combined Heat and Power plant. By 2023, it is expected to supply 25.7 tons of steam per hour all year round. The additional steam demand in Daeduk Industrial Complex is estimated as 101,537 tons/year. Surplus biogas will be supplied through an additional 960-m new installation. The cost of biogas is estimated at 30% of the unit biogas production cost. Daejeon Combined Heat and Power plant expects to make 60% additional profit, and Daeduk Industrial Complex and the communities nearby expect to achieve 10% cost savings. It also reduces the dependence of energy on fossil fuels, contributes to national environmental energy policy in reduction in greenhouse gases, creates competitiveness in local business and reduces corporate tax and generates revenue. 相似文献
7.
Lee CS Lim YW Kim HH Yang JY Shin DC 《Environmental science and pollution research international》2012,19(5):1629-1639
Background, aim, and scope
The purpose of this study was to monitor and present the heavy metal concentrations in the blood of residents of areas near municipal waste incinerators (MWIs), who are more prone to environmental pollution. We also sought to compare and analyze the residents?? perception of environmental pollution as one of the factors affecting heavy metal concentrations in the blood using a survey about the perceived damage caused by the facilities. Since heavy metal levels in the blood can be affected not only by local environmental pollution but also by personal and occupational factors, heavy metal levels in the blood need to be verified and consistently monitored.Methods
Residents who live within 300?m of MWIs in Seoul are acknowledged to be under indirect influence according to the Waste Disposal Act. A survey was given to 841 residents living within 300?m of a MWI from 2006 to 2009. The concentrations of heavy metals (lead, cadmium, and mercury) in the blood were measured in the 841 surveyed residents and in 105 residents in reference areas. Additionally, the perception of the damage caused by municipal waste incinerators was investigated using scores from 1 to 5 on a Likert scale.Results
The measurements of the heavy metal concentrations in the blood showed that the mean concentrations of lead, cadmium, and mercury were 43.1, 1.7, and 1.3?ug/L, respectively. The blood levels of lead and cadmium were slightly higher in the group of the subjects who had resided the longest near the municipal waste incinerators. When compared with the domestic investigation by the Ministry of Environment, the concentrations of lead and cadmium were a little higher, while that of mercury was a little lower. Overall, there was no significant difference in the distribution of heavy metal levels in the blood among age groups. Additionally, the investigation of the perceived damage from municipal waste incinerators showed that the subjects 相似文献8.
Kim SS Kang YS Lee HD Kim JK Hong SC 《Journal of the Air & Waste Management Association (1995)》2012,62(2):235-241
In this study, the physicochemical properties of the char of Indonesian SM coal following heat treatment at various temperatures were evaluated using X-ray photoelectron spectroscopy (XPS), Fourier-transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), and morphological and specific surface area analysis. Based on these analyses, heat treatment of coal was determined to be the most effective in increasing the coal rank. In the XPS analysis, the C-O and C-O-C groups and quaternary-N species were found to be of a lower grade coal when the pretreatment temperature decreased, meanwhile the C-C group and pyridinic species increased. In the FT-IR analysis, the collapse of the C-O and C-O-C group was observed due to the collapse of the ether group. In SEM and Brunauer-Emmett-Teller (BET) analysis, a decrease in the ether group was shown to be accompanied with the formation of micropores. 相似文献
9.
This paper presents a design method by which the overflow risk related to a detention for managing nonpoint pollutant sources in urban areas can be evaluated. The overall overflow risk of a nonpoint pollutant sources control detention can be estimated by inherent overflow risk and operational overflow risk. For the purpose of calculating overflow risk, the 3-parameter mixed exponential distribution is applied to describe the probability distribution of rainfall event depth. As a rainfall-runoff calculation procedure required for deriving a rainfall capture curve, the U.S. Natural Resources Conservation Service runoff curve number method is applied to consider the nonlinearity of the rainfall-runoff relation. Finally, the detention overflow risk is assessed with respect to the detention design capacity and drainage time. The proposed overflow risk assessment is expected to provide a baseline to determine quantitative parameters in designing a nonpoint sources control detention. 相似文献
10.
Park SS Kozawa K Fruin S Mara S Hsu YK Jakober C Winer A Herner J 《Journal of the Air & Waste Management Association (1995)》2011,61(10):1046-1056
Fuel-based emission factors for 143 light-duty gasoline vehicles (LDGVs) and 93 heavy-duty diesel trucks (HDDTs) were measured in Wilmington, CA using a zero-emission mobile measurement platform (MMP). The frequency distributions of emission factors of carbon monoxide (CO), nitrogen oxides (NO(x)), and particle mass with aerodynamic diameter below 2.5 microm (PM2.5) varied widely, whereas the average of the individual vehicle emission factors were comparable to those reported in previous tunnel and remote sensing studies as well as the predictions by Emission Factors (EMFAC) 2007 mobile source emission model for Los Angeles County. Variation in emissions due to different driving modes (idle, low- and high-speed acceleration, low- and high-speed cruise) was found to be relatively small in comparison to intervehicle variability and did not appear to interfere with the identification of high emitters, defined as the vehicles whose emissions were more than 5 times the fleet-average values. Using this definition, approximately 5% of the LDGVs and HDDTs measured were high emitters. Among the 143 LDGVs, the average emission factors of NO(x), black carbon (BC), PM2.5, and ultrafine particle (UFP) would be reduced by 34%, 39%, 44%, and 31%, respectively, by removing the highest 5% of emitting vehicles, whereas CO emission factor would be reduced by 50%. The emission distributions of the 93 HDDTs measured were even more skewed: approximately half of the NO(x) and CO fleet-average emission factors and more than 60% of PM2.5, UFP, and BC fleet-average emission factors would be reduced by eliminating the highest-emitting 5% HDDTs. Furthermore, high emissions of BC, PM2.5, and NO(x) tended to cluster among the same vehicles. 相似文献