1
1.
ABSTRACT

Recent experiments confirm field experience that duct cleaning alone may not provide adequate protection from regrowth of fungal contamination on fiberglass duct liner (FGDL). Current recommendations for remediation of fungally contaminated fiberglass duct materials specify complete removal of the materials. But removal of contaminated materials can be extremely expensive. Therefore, a common practice in the duct-cleaning industry is the postcleaning use of antimicrobial surface coatings with the implication that they may contain or limit regrowth.

Little information is available on the efficacy of these treatments. This paper describes a study to evaluate whether three commercially available antimicrobial coatings, placed on a cleaned surface that 1 year previously had been actively growing microorganisms, would be able to prevent regrowth. The three coatings contained different active antimicrobial compounds. All three of the coatings were designed for use on heating, ventilation, and air conditioning (HVAC) system components or interior surfaces of lined and unlined duct systems. Coating I was a polyacrylate copolymer containing zinc oxide and borates. Coating II was an acrylic coating containing decabromodiphenyl oxide and antimony trioxide. Coating III was an acrylic primer containing a phosphated quaternary amine complex.

The study included field and laboratory assessments. The three treatments were evaluated in an uncontrolled field setting in an actual duct system. The laboratory study broadened the field study to include a range of humidities under controlled conditions. Both static and dynamic chamber laboratory experiments were performed. The results showed that two of the three antimicrobial coatings limited the regrowth of fungal contamination, at least in the short term (the 3-month time span of the study); the third did not. Before use in the field, testing of the efficacy of antimicrobial coatings under realistic use conditions is recommended because antimicrobials have different baseline activities and interact differently with the substrate that contains them and their local environment.  相似文献   
2.
Environmental fungi become a potential Indoor Air Quality (IAQ) problem when adequate moisture and nutrients are present in building materials. Because of their potential to rapidly spread contamination throughout a building, ventilation system materials are of particular significance as potential microbial contamination sources. Current recommendations are to discard fibrous glass insulation that appears to be wet or moldy. Unfortunately, this advice is not always followed. Instead, cleaning is sometimes being used in buildings to remediate fibrous glass duct liner that is already contaminated with microbial growth. The objectives of this research program were to: 1) determine, under dynamic test conditions, whether fungal spore levels on heating, ventilating, and air-conditioning (HVAC) duct material surfaces could be substantially reduced by thorough vacuum cleaning, 2) evaluate whether subsequent fungal growth could be limited or contained by mechanical cleaning, and 3) provide data concerning the advisability of cleaning duct materials. The constant high relative humidity (RH) environment to which the test materials were exposed during this study was selected as a favorable growth environment that is frequently found in Southeastern United States HVAC systems. The results showed that, following cleaning, the levels of the two test fungi, A. versicolor and P. chrysogenum, recovered to preclean levels within 6 weeks. Therefore, mechanical cleaning by contact vacuuming alone was able to only temporarily reduce the surface fungal load. The current guidelines to discard contaminated materials should be followed.  相似文献   
3.
The incidences of allergies, allergic diseases and asthma are increasing world wide. Global climate change is likely to impact plants and animals, as well as microorganisms. The World Health Organization, U.S. Environmental Protection Agency, U.S. Department of Agriculture, U.S. Department of Health and Human Services, and the Intergovernmental Panel on Climate Change cite increased allergic reactions due to climate change as a growing concern. Monitoring of indoor and ambient particulate matter (PM) and the characterization of the content for biological aerosol concentrations has not been extensively performed. Samples from urban and rural North Carolina (NC), and Denver (CO), were collected and analyzed as the goal of this research. A study of PM10 (<10 μm in aerodynamic diameter) and PM2.5 (<2.5 μm in aerodynamic diameter) fractions of ambient bioaerosols was undertaken for a six month period to evaluate the potential for long-term concentrations. These airborne bioaerosols can induce irritational, allergic, infectious, and chemical responses in exposed individuals. Three separate sites were monitored, samples were collected and analyzed for mass and biological content (endotoxins, (1,3)-β-d-glucan and protein). Concentrations of these bioaerosols were reported as a function of PM size fraction, mass and volume of air sampled. The results indicated that higher concentrations of biologicals were present in PM10 than were present in PM2.5, except when near-roadway conditions existed. This study provides the characterization of ambient bioaerosol concentrations in a variety of areas and conditions.  相似文献   
4.
Fipronil termiticide belongs to phenyl-pyrazole class of chemical compounds. It has broad-spectrum activity particularly against house hold pests such as cockroaches, mosquitoes, locusts, ticks, and fleas at both larval and adult stages. At high dosage it can be used to control subterranean termites in building foundations. To evaluate long term efficacy against termites the persistence and vertical distribution of fipronil was studied under natural weather conditions of Dehradun, India. Fipronil was applied at four concentrations i.e. 0.05, 0.1, 0.25 and 0.5% a.i ha−1 by drenching 17 × 17 in.2 plot prepared as per modified ground board test. Soil samples were collected after 22, 38 and 56 months of treatment up to the depth of 75 cm. The soil core was cut into five distinct sections i.e. 0–15, 15–30, 30–45, 45–60 and 60–75 cm depth. The residues were extracted by shaking 20 g soil sample with acetone. The acetone extract was concentrated and cleaned-up over florisil column. Fipronil residues were estimated on GLC at 220, 260, and 300°C oven, injector and detector temperature respectively. Fipronil was found to persist beyond 56 months after application. Two metabolites viz. desulfinyl and sulfide-fipronil were detected in sampling after 22 months of application that also dissipated with time. Fipronil residues were found up to 60 cm depth. The residues in deeper layers dissipate slowly with time and after 56 months of treatment residues were detected only up to 30 cm depth.  相似文献   
5.
Goal, Scope and Background Reducing occupant exposure to indoor mold is the goal of this research, through the efficacy testing of antimicrobial cleaners. Often mold contaminated building materials are not properly removed, but instead surface cleaners are applied in an attempt to alleviate the problem. The efficacy of antimicrobial cleaners to remove, eliminate or control mold growth on surfaces can easily be tested on non-porous surfaces. However, the testing of antimicrobial cleaner efficacy on porous surfaces, such as those found in the indoor environment such as gypsum board can be more complicated and prone to incorrect conclusions regarding residual organisms. The mold Stachybotrys chartarum has been found to be associated with idiopathic pulmonary hemorrhage in infants and has been studied for toxin production and its occurrence in water damaged buildings. Growth of S. chartarum on building materials such as gypsum wallboard has been frequently documented. Methods Research to control S. chartarum growth using 13 separate antimicrobial cleaners on contaminated gypsum wallboard has been performed in laboratory testing. Popular brands of cleaning products were tested by following directions printed on the product packaging. Results A variety of gypsum wallboard surfaces were used to test these cleaning products at high relative humidity. The results indicate differences in antimicrobial efficacy for the six month period of testing. Discussion Results for the six types of GWB surfaces varied extensively. However, three cleaning products exhibited significantly better results than others. Lysol All-Purpose Cleaner-Orange Breeze (full strength) demonstrated results which ranked among the best in five of the six surfaces tested. Both Borax and Orange Glo Multipurpose Degreaser demonstrated results which ranked among the best in four of the six surfaces tested. Conclusions The best antimicrobial cleaner to choose is often dependent on the type of surface to be cleaned of S. chartarum contamination. For Plain GWB, no paint, the best cleaners were Borax, Lysol All-Purpose Cleaner-Orange Breeze (full strength), Orange Glo Multipurpose Degreaser, and Fantastik Orange Action. Recommendations and Perspectives These results are not meant to endorse the incomplete removal of mold contaminated building materials. However, it is recognized that complete removal may not always be possible and solutions to control mold regrowth may contribute to reduced occupant exposure. Current recommendations of removal and replacement of porous building materials should be followed. It is not the intension of this discussion to endorse any product. Reporting on the performance of these products under the stated conditions was and remains the only purpose. ESS-Submission Editor: Dr. Lee Young (youngrisk@bresnan.net)  相似文献   
6.
Recent experiments confirm field experience that duct cleaning alone may not provide adequate protection from regrowth of fungal contamination on fiberglass duct liner (FGDL). Current recommendations for remediation of fungally contaminated fiberglass duct materials specify complete removal of the materials. But removal of contaminated materials can be extremely expensive. Therefore, a common practice in the duct-cleaning industry is the postcleaning use of antimicrobial surface coatings with the implication that they may contain or limit regrowth. Little information is available on the efficacy of these treatments. This paper describes a study to evaluate whether three commercially available antimicrobial coatings, placed on a cleaned surface that 1 year previously had been actively growing microorganisms, would be able to prevent regrowth. The three coatings contained different active antimicrobial compounds. All three of the coatings were designed for use on heating, ventilation, and air conditioning (HVAC) system components or interior surfaces of lined and unlined duct systems. Coating I was a polyacrylate copolymer containing zinc oxide and borates. Coating II was an acrylic coating containing decabromodiphenyl oxide and antimony trioxide. Coating III was an acrylic primer containing a phosphated quaternary amine complex. The study included field and laboratory assessments. The three treatments were evaluated in an uncontrolled field setting in an actual duct system. The laboratory study broadened the field study to include a range of humidities under controlled conditions. Both static and dynamic chamber laboratory experiments were performed. The results showed that two of the three antimicrobial coatings limited the regrowth of fungal contamination, at least in the short term (the 3-month time span of the study); the third did not. Before use in the field, testing of the efficacy of antimicrobial coatings under realistic use conditions is recommended because antimicrobials have different baseline activities and interact differently with the substrate that contains them and their local environment.  相似文献   
7.
Exposures from indoor environments are a major issue for evaluating total long-term personal exposures to the fine fraction (<2.5 microm in aerodynamic diameter) of particulate matter (PM). It is widely accepted in the indoor air quality (IAQ) research community that biocontamination is one of the important indoor air pollutants. Major indoor air biocontaminants include mold, bacteria, dust mites, and other antigens. Once the biocontaminants or their metabolites become airborne, IAQ could be significantly deteriorated. The airborne biocontaminants or their metabolites can induce irritational, allergic, infectious, and chemical responses in exposed individuals. Biocontaminants, such as some mold spores or pollen grains, because of their size and mass, settle rapidly within the indoor environment. Over time they may become nonviable and fragmented by the process of desiccation. Desiccated nonviable fragments of organisms are common and can be toxic or allergenic, depending upon the specific organism or organism component. Once these smaller and lighter fragments of biological PM become suspended in air, they have a greater tendency to stay suspended. Although some bioaerosols have been identified, few have been quantitatively studied for their prevalence within the total indoor PM with time, or for their affinity to penetrate indoors. This paper describes a preliminary research effort to develop a methodology for the measurement of nonviable biologically based PM, analyzing for mold and ragweed antigens and endotoxins. The research objectives include the development of a set of analytical methods and the comparison of impactor media and sample size, and the quantification of the relationship between outdoor and indoor levels of bioaerosols. Indoor and outdoor air samples were passed through an Andersen nonviable cascade impactor in which particles from 0.2 to 9.0 microm were collected and analyzed. The presence of mold, ragweed, and endotoxin was found in all eight size ranges. The presence of respirable particles of mold and pollen found in the fine particle size range from 0.2 to 5.25 microm is evidence of fragmentation of larger source particles that are known allergens.  相似文献   