首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   17篇
  免费   0篇
综合类   2篇
基础理论   1篇
污染及防治   13篇
社会与环境   1篇
  2021年   1篇
  2013年   2篇
  2008年   1篇
  2007年   2篇
  2003年   1篇
  2002年   1篇
  2000年   1篇
  1998年   1篇
  1984年   4篇
  1982年   1篇
  1981年   1篇
  1958年   1篇
排序方式: 共有17条查询结果,搜索用时 15 毫秒
1.
Abstract

Most environmental tobacco smoke (ETS) issues from the tips of smoldering cigarettes between puffs. Smokeless ashtrays are designed to reduce ETS exposure by removing particulate and/or gas-phase contaminants from this plume. This paper describes an experimental investigation of the effectiveness of four smokeless ashtrays: two commercial devices and two prototypes constructed by the authors. In the basic experimental protocol, one or more cigarettes was permitted to smolder in a room. Particulate or gas-phase pollutant concentrations were measured in the room air over time. Device effectiveness was determined by comparing pollutant concentrations with the device in use to those obtained with no control device. A lung deposition model was applied to further interpret device effectiveness for particle removal. The commercial ashtrays were found to be substantially ineffective in removing ETS particles because of the use of low-quality filter media and/or the failure to draw the smoke through the filter. A prototype ashtray using HEPA filter material achieved better than 90% particle removal efficiency. Gasphase pollutant removal was tested for only one prototype smokeless ashtray, which employed filters containing activated carbon and activated alumina. Removal efficiencies for the 18 gas-phase compounds measured (above the detection limit) were in the range of 70 to 95%.  相似文献   
2.
N Adams  AJ Dobbs 《Chemosphere》1984,13(8):965-971
Two different test methods for assessing the toxicity of aminotriazole to Selenastrum capricornutum are compared. Growth medium composition is demonstrated to have a significant effect on the toxicity of aminotriazole.  相似文献   
3.
4.
5.
Cooling buildings with large airflow rates of outside air when temperatures are favorable is an established energy-saving measure. In data centers, this strategy is not widely used, owing to concerns that it would cause increased indoor levels of particles of outdoor origin, which could damage electronic equipment. However, environmental conditions typical of data centers and the associated potential for equipment failure are not well characterized. This study presents the first published measurements of particle concentrations in operating data centers. Indoor and outdoor particle measurements were taken at eight different sites in northern California for particulate matter 0.3–5.0 μm in diameter. One of the data centers has an energy-efficient design that employs outside air for cooling, while the rest use conventional cooling methods. Ratios of measured particle concentrations in the conventional data centers to the corresponding outside concentrations were significantly lower than those typically found in office or residential buildings. Estimates using a material-balance model match well with empirical results, indicating that the dominant particle sources and losses have been identified. Measurements taken at the more energy-efficient site show nearly an order of magnitude increase in particle concentration when ventilation rates were high. The model indicates that this increase may be even higher when including particles smaller than the monitoring-equipment size limitation. Even with the increases, the measured particle concentrations are still below concentration limits recommended in industry standards.  相似文献   
6.
Growth, lipid peroxidation, different antioxidative enzymes and metal accumulation were studied in Lemna polyrrhiza treated with different concentrations (1-40 ppm) of CdSO4. The growth of the plant was slightly enhanced with 1 ppm, while higher concentrations retarted growth and multiplication of fronds, the effect being concentration and dose dependant. Increase in malondialdehyde content was insignificant after the first week but a prolonged exposure led to significant (p < 0.05) increase of about 38% and 45% over the control in 20 and 30 ppm, respectively after four weeks. Catalase (EC 1.11.1.6; CAT) activity increased at low concentration, but it declined to 42% and 54% at 40 ppm after 6 and 30 days, respectively Superoxide dismutase (EC 1.15.1.1; SOD), ascorbate peroxidase (EC 1.11.1.11;APx) and glutathione reductase (EC 1.6.4.2) increased at both low as well at high concentrations, but a prolonged exposure to high concentration of Cd (40 ppm) led to significant (p < 0.05) decline in the mean activities of these antioxidant enzymes. Accumulation of Cd in biomass was concentration and time dependant However at high concentration of 40 ppm, Cd accumulation did not increase significantly (p < 0.05) with time. Increased activities of antioxidant enzymes in Cd treated plants suggest that metal tolerance in L. polyrrhiza might be associated to the changes of antioxidant enzymatic activities.  相似文献   
7.
AJ Dobbs  C Grant 《Chemosphere》1981,10(10):1185-1193
The octachlorodibenzo-p-dioxin (OCDD) concentrations have been determined in aged samples of commercial pentachlorophenol (PCP), in wood protection formulations containing PCP and in wood treated with PCP as a preservative or as an anti-sapstain treatment. The concentrations of OCDD found in the various samples are within the range expected from the amount of commercial PCP initially present in the samples. In view of the known stability of OCDD the results are interpreted as indicating that the formulation, treatment and ageing processes have not led to any substantial conversion of PCP to OCDD; although one result indicates that outdoor exposure of treated samples increased the OCDD concentration by a factor of approximately 2 after 312 years. Analysis of aged samples of treated wood indicate that OCDD is lost much less rapidly from the wood than PCP.  相似文献   
8.
We report on computational fluid dynamics (CFD) predictions of mixing time of a pollutant in an unventilated, mechanically mixed, isothermal room. The study aims to determine: (1) the adequacy of the standard Reynolds Averaged Navier Stokes two-equation (k−) turbulence model for predicting the mixing time under these conditions and (2) the extent to which the mixing time depends on the room airflow, rather than the source location within the room. The CFD simulations modeled the 12 mixing time experiments performed by Drescher et al. (Indoor Air 5 (1995) 204) using a point pulse release in an isothermal, sealed room mechanically mixed with variable power blowers. Predictions of mixing time were found in good agreement with experimental measurements, over an order of magnitude variation in blower power. Additional CFD simulations were performed to investigate the relation between pollutant mixing time and source location. Seventeen source locations and five blower configurations were investigated. Results clearly show large dependence of the mixing time on the room airflow, with some dependence on source location. We further explore dependence of mixing time on the velocity and turbulence intensity at the source location. Implications for positioning air-toxic sensors in rooms are briefly discussed.  相似文献   
9.
Optimizing real-time sensor systems to detect and identify relevant characteristics of an indoor contaminant event is a challenging task. The interpretation of incoming sensor data is confounded by uncertainties in building operation, in the forces driving contaminant transport, and in the physical parameters governing transport. In addition, simulation tools used by the sensor interpretation algorithm introduce modeling uncertainties. This paper explores how the time scales inherent in contaminant transport influence the information that can be extracted from real-time sensor data. In particular, we identify three time scales (within room mixing, room-to-room transport, and removal from the building) and study how they affect the ability of a Bayesian Monte Carlo (BMC) sensor interpretation algorithm to identify the release location and release mass from a set of experimental data, recorded in a multi-floor building. The research shows that some limitations in the BMC approach do not depend on details of the models or the algorithmic implementation, but rather on the physics of contaminant transport. These inherent constraints have implications for the design of sensor systems.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号