首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   8篇
  免费   0篇
安全科学   7篇
污染及防治   1篇
  2020年   1篇
  2013年   4篇
  2007年   1篇
  2005年   2篇
排序方式: 共有8条查询结果,搜索用时 15 毫秒
1
1.
Exposure to methyl methacrylate (MMA), total dust and health symptoms were investigated in 20 dental laboratories located in Tehran, Iran. Time-weighted average (TWA) of MMA and peak concentrations were determined, using XAD-2 tubes followed by GC-FID analysis. Total dusts were evaluated gravimetrically. Health symptoms were asked using a questionnaire. TWA for technicians with direct and indirect exposure to MMA were 327.28 +/- 79.42 and 282.9 +/- 41.84 mg/m3, respectively. Peak concentration of MMA for those technicians were 337.0 +/- 36.81 and 328.88 +/- 45.40 mg/m3, respectively. There were no significant differences between TWA of MMA and peak concentration in different weekly workdays; however, within-day variations were observed (P < .05). TWA of MMA and peak concentration correlation with the laboratory volume were 0.61-0.65. Dust exposure of technicians was 2.35 +/- 2.70 mg/m3. Cough and skin dryness were the common health symptoms. Smoking and asbestos exposure history were factors influencing cough prevalence (p < .05). It is concluded that the current Short-Term Exposure Limit (STEL) is not low enough to protect technicians against the adverse effects caused by MMA.  相似文献   
2.
Lead is an important constituent widely used in different industrial processes. For evaluation of workers' exposure to trace toxic metal of Pb (II), solid-phase extraction (SPE) was optimized. SPE using mini columns filled with XAD-4 resin was developed with regard to sample pH, ligand concentration, loading flow rate, elution solvent, sample volume, elution volume, the amount of resins, and sample matrix interferences. Lead ions were retained on a solid sorbent and then eluted, followed by a simple determination of analytes with flame atomic absorption spectrometery. The obtained recoveries of metal ions were greater than 92%. This method was validated with 3 different pools of spiked urine samples; it showed a good reproducibility over 6 consecutive days as well as 6 within-day experiments. This optimized method can be considered successful in simplifying sample preparation for a trace residue analysis of lead in different matrices when evaluating occupational and environmental exposures is required.  相似文献   
3.
This study evaluated the influence of welding on pulmonary functions in welders. Spirometry tests were performed before and after work shift in 91 welders and 25 clerks (control group). We examined forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), FEV1/FVC ratio and forced expiratory flow 25%-75% (FEF 25–75). Significant differences were found for FVC and FEV1/FVC between welders and the control group in pre- and post-shift measurements (p < .001). In welders, smoking and nonsmoking habit had no significant effects on any pulmonary indices before or after shift. Work experience and fume concentrations also had no significant effects on the majority of spirometric indices (p > .05). Most welders had at least 1 of the respiratory symptoms. Significant differences were found between pre- and post-shift indices (as percentage of predicted values calculated with spirometer) and between the welders engaged in some welding tasks and the control group before work shift. This study documented work-related changes in pulmonary functions in the welders and marked drops in these functions without symptoms in some welders.  相似文献   
4.
Exposure to methyl methacrylate (MMA), total dust and health symptoms were investigated in 20 dental laboratories located in Tehran, Iran. Time-weighted average (TWA) of MMA and peak concentrations were determined, using XAD-2 tubes followed by GC-ID analysis. Total dusts were evaluated gravimetrically. Health symptoms were asked using a questionnaire. TWA for technicians with direct and indirect exposure to MMA were 327.28 ± 79.42 and 282.9 ± 41.84 mg/m3 , respectively. Peak concentration of MMA for those technicians were 337.0 ± 36.81 and 328.88 ± 45.40 mg/m3, respectively.

There were no significant differences between TWA of MMA and peak concentration in different weekly workdays; however, within-day variations were observed (P < .05).

TWA of MMA and peak concentration correlation with the laboratory volume were 0.61-0.65. Dust exposure of technicians was 2.35 ± 2.70 mg/m3. Cough and skin dryness were the common health symptoms. Smoking and asbestos exposure history were factors influencing cough prevalence (p < .05).

It is concluded that the current Short-Term Exposure Limit (STEL) is not low enough to protect technicians against the adverse effects caused by MMA.  相似文献   
5.
Factors affecting solid phase extraction (SPE) of trans,trans-muconic acid (ttMA), as a benzene biomarker, including sample pH, sample concentration, sample volume, sample flow rate, washing solvent, elution solvent, and type of sorbent were evaluated. Extracted samples were determined by HPLC-UV(highperformance liquid chromatography-ultraviolet). The analytical column was C18, UV wave length was 259 nm, and the mobile phase was H2O/methanol/acetic acid run at flow rate of 1 ml/min. A strong anion exchange silica cartridge was found successful in simplifying SPE. There was a significant difference between recoveries of ttMA when different factors were used (p < .001). An optimum recovery was obtained when sample pH was adjusted at 7. There was no significant difference when different sample concentrations were used (p > .05). The optimized method was then validated with 3 different pools of samples showing good reproducibility over 6 consecutive days and 6 within-day experiments.  相似文献   
6.
Environmental Science and Pollution Research - In the present paper, micro-mesoporous Fe-MIL-101/OAC composite using in situ incorporation of Fe-MIL-101 into oxidized activated carbon was...  相似文献   
7.
This study describes optimization of headspace solid phase microextraction followed by gas chromatography equipped with a flame ionization detector for toluene at trace level in spiked urine. The parameters affecting the extraction and gas chromatographic determination of analytes were studied: extraction time and temperature; desorption time and temperature; addition of NaCl; and pH, volume and agitation of the sample. Optimized headspace extraction was carried out at 30 °C for 6 min in the presence of 0.2 g-m-1of NaCl in the sample solution. Also, sample volume and sample pH were optimized at 5 ml and 7 (neutral pH), respectively. Desorption of the analytes was carried out at 250 °C for 60 s. The optimized procedure was validated with 3 different pools of spiked urine; it showed good reproducibility over 6 consecutive days and 6 within-day experiments. The study also determined the accuracy, linearity and detection limits of this method.  相似文献   
8.
Factors affecting solid phase extraction (SPE) of trans,trans-muconic acid (ttMA), as a benzene biomarker, including sample pH, sample concentration, sample volume, sample flow rate, washing solvent, elution solvent, and type of sorbent were evaluated. Extracted samples were determined by HPLC-UV (high performance liquid chromatography-ultraviolet). The analytical column was C18, UV wave length was 259 nm, and the mobile phase was H(2)O/methanol/acetic acid run at flow rate of 1 ml/min. A strong anion exchange silica cartridge was found successful in simplifying SPE. There was a significant difference between recoveries of ttMA when different factors were used (p < .001). An optimum recovery was obtained when sample pH was adjusted at 7. There was no significant difference when different sample concentrations were used (p > .05). The optimized method was then validated with 3 different pools of samples showing good reproducibility over 6 consecutive days and 6 within-day experiments.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号