首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   23篇
  免费   0篇
污染及防治   17篇
评价与监测   6篇
  2022年   1篇
  2021年   1篇
  2013年   1篇
  2006年   1篇
  2004年   1篇
  2003年   1篇
  2002年   4篇
  1984年   2篇
  1983年   3篇
  1982年   2篇
  1981年   3篇
  1979年   1篇
  1977年   2篇
排序方式: 共有23条查询结果,搜索用时 31 毫秒
1.
A diffusive sampling method for the determination of methyl isocyanate (MIC) in air is introduced. MIC is collected using a glass fiber filter impregnated with 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole (NBDPZ). The urea derivative formed is desorbed from the filter with acetonitrile and analyzed by means of high-performance liquid chromatography (HPLC) using fluorescence detection (FLD) with lambdaex = 471 nm and lambdaex = 540 nm. Additionally, a method was developed using tandem mass spectrometric (MS-MS) detection, which was performed as selected reaction monitoring (SRM) on the transition [MIC-NBDPZ + H]+ (m/z 307) to [NBDPZ + H]+ (m/z 250). The diffusive sampler was tested with MIC concentrations between 1 and 35 microg m(-3). The sampling periods varied from 15 min to 8 h, and the relative humidity (RH) was set from 20% up to 80%. The sampling rate for all 15 min experiments was determined to be 15.0 mL min(-1) (using HPLC-FLD) with a relative standard deviation of 9.9% for 56 experiments. At 80% RH, only 15 min sampling gave acceptable results. Further experiments revealed that humidity did not affect the MIC derivative but the reagent on the filter prior to and during sampling. The sampling rate for all experiments (including long term sampling) performed at 20% RH was found to be 15.0 mL min(-1) with a relative standard deviation of 6.3% (N = 42). The limit of quantification was 3 microg m(-3) (LC-MS-MS: 1.3 microg m(-3)) for 15 min sampling periods and 0.2 microg m(-3) (LC-MS-MS: 0.15 microg m(-3)) for 8 h sampling runs applying fluorescence detection.  相似文献   
2.
A diffusive sampling method for determination of methyl isocyanate in air has been developed. A glass fibre filter impregnated with 1-(2-methoxyphenyl)piperazine in a commercially available diffusive sampling device was used to collect methyl isocyanate and the derivative formed was analysed with LC-MS/MS. The sampling rate was determined to be 15.6 ml min(-1), with a relative standard deviation of 7.3%. The sampler was validated for sampling periods from 15 min to 8 h, for relative humidities from 20% to 80% and for concentrations from I to 46 microg m(-3). A field validation was also made and the diffusive sampling results showed no difference compared to a pumped reference method. The impregnated filters have to be stored apart from the diffusive sampler housing and loaded into the sampler prior to each sampling.  相似文献   
3.
This paper describes solute transport modeling carried out as a part of an assessment of the long-term radiological safety of a planned deep rock repository for spent nuclear fuel in Forsmark, Sweden. Specifically, it presents transport modeling performed to locate and describe discharge areas for groundwater potentially carrying radionuclides from the repository to the surface where man and the environment could be affected by the contamination. The modeling results show that topography to large extent determines the discharge locations. Present and future lake and wetland objects are central for the radionuclide transport and dose calculations in the safety assessment. Results of detailed transport modeling focusing on the regolith and the upper part of the rock indicate that the identification of discharge areas and objects considered in the safety assessment is robust in the sense that it does not change when a more detailed model representation is used.  相似文献   
4.
The porous polymers Amberlite XAD-2 and XAD-7 were evaluated for the sampling of ethylene glycol, 2-methoxyethanol, 2-ethoxyethanol, 2-butoxyethanol and 2-ethoxyethyl acetate in work-room air. Using diethyl ether desorption, these adsorbents were found excellent for the compounds studied.  相似文献   
5.
6.
A sampling procedure for 2,4- and 2,6-toluenediisocyanate (TDI) and 4,4′-diphenylmethane diisocyanate (MDI) in the range 0.007-0.7 mg/m3 in a 15 L air sample is described. The sampling is performed with 9-(N-methylaminomethyl)-anthracene (MAMA) adsorbed on a solid sorbent, Amberlite XAD-2. The recoveries are 80–100% in this chemosorption reaction. The urea derivatives are desorbed with N,N-dimethylformamide and analysed by high performance liquid chromatography (HPLC). Samples and prepared chemosorption tubes are stable for at least two weeks if stored in the dark. To complete the investigation, field measurements of TDI were performed in an industrial atmosphere.  相似文献   
7.
The influence of air humidity on the sampling efficiency of Amberlite XAD porous polymers and activated charcoal was studied by determining the recovery of various organics at 20% and 85% relative humidity. The sampling efficiency of XAD-7 was found to decrease with increasing relative humidity, while the sampling efficiency of XAD-2 and activated charcoal was relatively unaffected for the compounds studied. Activated charcoal had a greater capacity than Amberlite XAD for several types of compounds, however.  相似文献   
8.
A sampling method for polycyclic aromatic hydrocarbons (PAH) in workplace atmospheres using a standard glass fiber filter with a back-up section of Amberlite XAD-2 is described. Filters and XAD are solvent-desorbed and, without further clean-up, the solutions are submitted to high performance liquid chromatographic analysis using fluorimetric detection. Recovery of PAH from XAD-2 was studied, and was found to be in the range 80–100%. The sampling method was evaluated in a coke plant, an aluminium plant and in a creosote impregnating plant. The method described is rapid and sensitive for the determination of the most important workplace PAH, and accounts for both particulate and gaseous PAH.  相似文献   
9.
A sampling and analysis method for PAH from two-stroke engines is described. The method, which uses a standard glass fiber filter with a back-up section of Amberlite XAD-2 for sampling and GC or GC-MS for analysis, is suitable for both emission studies and occupational studies during logging. Filters and XAD-2 are desorbed with cyclohexane in an ultrasonic bath. After separation on a silica-gel micro column, the samples are submitted to analyses by capillary GC. The method is simple and covers both gaseous and particulate PAH. Naphthalene and alkyl substituted naphthalenes are also quantified.  相似文献   
10.
Diffusive samplers for monitoring of air quality are user-friendly devices that can normally be operated by the user himself. Hence these samplers are suitable for self-assessment. Practical and work organisational aspects of self-assessment of chemical exposure were studied in different occupational settings. It was found that the diffusive sampler used in these studies, the Perkin-Elmer tube in combination with thermal desorption, worked well for the purpose and could be correctly handled by the individuals using it. The results from self-assessments agreed well with expert measurements carried out by an occupational hygienist. However, in order to obtain a sustainable system of self-assessment strong organizational support is needed.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号