It is known that globalization has led first- and second-tier cities’ urban restructuring trajectories, excreted pressures, and caused tremendous socioeconomic volatility. This resulted in marginalized communities in dire of social empowerment, employment structure variance, and industry sectoral adjustment. Moreover, recent successive climate and health crisis unfolded and affirmed the state of our urban incompetence to sustain socioeconomic resilience or otherwise; lacking swift responses in providing critical management and services, cites are facing multifaceted challenges. Urban well-being and resilience are at stake. Although the environmental and health dimensional effects are apparent, this study ascertains that the transept multi-scalar analysis within the urban socioeconomic structure is crucial in sustaining core resilience to foster health and well-being of the community. As an integral part of the investigation, the revised DPSIR assessment framework is applied to evaluate the sectoral shift; spatial structure disarray and urban codependence degree are examined within the Taipei metropolitan area (TMA), a medium size but densely populated metropolitan area in Taiwan. The place-based DPSIR analysis ascertained the states and impacts in TMA: (1) A population decline speeded the restructuring of the urban core, while the impact of demographic aging and shrinkage rate mandates proper management and planning responses to the decline process; (2) the socioeconomic state effect is determined but does not critically affect the periphery zone, while an uneven demographic shift within the urban core necessitates dynamic adjustment responses to appropriately provide intergenerational services; (3) the uneven sector redistribution stimulated the core’s spatial and structural inter-dependency with peripheral zones, requiring governance with tighter cross-administration cooperation among respective public sectors; and (4) facing the sector/temporal and demographic pressure, urban cohesiveness in the TMA is greatly affected, which in turn disrupts the resilience pathway toward a cohesion. The study ascertained that the revised DPSIR framework could provide cities facing pressing socioeconomic drivers with effective analysis to allocate pressures, states, and impacts and formulate the necessary responses. To assure the socioeconomic resilience and urban cohesiveness, planning policy should carefully monitor and evaluate socio-demographic and sector redistribution factors to promote the urban resilience.
To clarify the aerosol hygroscopic growth and optical properties of the Pearl River Delta(PRD)region,integrated observations were conducted in Heshan City of Guangdong Province from October 19 to November 17,2014.The concentrations and chemical compositions of PM_(2.5),aerosol optical properties and meteorological parameters were measured.The mean value of PM_(2.5) increased from less than 35(excellent) to 35-75 μg/m~3(good) and then to greater than 75 μg/m~3(pollution),corresponding to mean PM_(2.5) values of 24.9,51.2,and 93.3 μg/m~3,respectively.The aerosol scattering hygroscopic growth factor(f(RH = 80%)) values were 2.0,2.12,and 2.18 for the excellent,good,and pollution levels,respectively.The atmospheric extinction coefficient(σext)and the absorption coefficient of aerosols(σ_(ap)) increased,and the single scattering albedo(SSA)decreased from the excellent to the pollution levels.For different air mass sources,under excellent and good levels,the land air mass from northern Heshan had lower f(RH) and σ_(sp) values.In addition,the mixed aerosol from the sea and coastal cities had lower f(RH) and showed that the local sources of coastal cities have higher scattering characteristics in pollution periods. 相似文献
PM_(2.5) separator directly affects the accuracy of PM_(2.5) sampling.The specification testing and evaluation for PM_(2.5) separator is particularly important,especially under China's wide variation of terrain and climate.In this study,first a static test apparatus based on polydisperse aerosol was established and calibrated to evaluate the performance of the PM_(2.5) separators.A uniform mixing chamber was developed to make particles mix completely.The aerosol concentration relative standard deviations of three test points at the same horizontal chamber position were less than 0.57%,and the particle size distribution obeyed logarithmic normal distribution with an R~2 of 0.996.The flow rate deviation between the measurement and the set point flow rate agreed to within ± 1.0% in the range of -40 to 50℃.Secondly,the separation,flow and loading characteristics of three cyclone separators(VSCC-A,SCC-A and SCC112) were evaluated using this system.The results showed that the 50% cutoff sizes(D_(50)) of the three cyclones were 2.48,2.47 and 2.44 μm when worked at the manufacturer's recommended flow rates,respectively.The geometric standard deviation(GSD) of the capture efficiency of VSCCA was 1.23,showed a slightly sharper than SCC-A(GSD = 1.27),while the SCC112 did not meet the relevant indicator(GSD = 1.2 ± 0.1) with a GSD = 1.44.The flow rate and loading test had a great effect on D_(50),while the GSD remained almost the same as before.In addition,the maintenance frequency under different air pollution conditions of the cyclones was summarized according to the loading test. 相似文献