1.
A biomonitoring survey using the moss species Hypnum cupressiforme Hedw. was conducted in the surroundings of two steel plants located in the North of Spain. Levels of V, Cr, Ni, Cu, Zn, As, Cd, Hg, Pb and N were determined. Very high concentrations in the areas of study were detected when compared to nearby unaffected regions. Similar trends were observed for all the elements in the differently orientated transects, showing an appreciable influence of the NW prevailing winds of the region in the dispersion of pollutants, as well as a clear decreasing gradient in the concentrations of metals in mosses within a distance of 1500 meters from the facilities. A differentiation between the elements emitted by the chimney as result of the industrial activity (V, Cr, Ni, Cu and As) and those with a high presence in steel slag deposits (Zn, Cd, Hg and Pb) was observed. The range of contamination was also established by means of the Contamination Factor, indicating a category 4 out of 6 categories, which shows the high levels reported in the areas of study. A different dynamic was registered for nitrogen regarding the rest of the heavy metals analysed except for Hg, probably due to the elevated volatility and mobility of both elements, as well as their high persistence in the atmosphere.  相似文献   
2.
The microbiological quality of urban wastewaters presents important environmental, sanitary, and political challenges. However, the variability of untreated wastewater quality is seldom known when it comes to microbial parameters. This study aims to evaluate the variability of microbiological quality in wastewater influents from different wastewater treatment plants connected to combined and partially separate sewer networks in the Parisian area and to evaluate the impact of this variability on the treatment efficiency and on the accuracy of wastewater effluent monitoring. The densities of fecal indicator bacteria (FIB), Escherichia coli and intestinal enterococci, and their partitioning on settleable particles were analyzed at the inlet of two wastewater treatment plants during dry weather (130 composite samples and 7 days sampled every 2 hours) and storm events (39 composite samples, and 7 rain courses) from 2008 to 2012. The results showed that fecal indicator densities vary according to the network characteristics and according to the meteorological conditions. During storm events, a significant dilution of E. coli and enterococci was observed, as well as a decrease in the settleable fraction of E. coli during the maximal impact of the storm. However, storm events did not significantly impact the regular FIB monitoring. FIB removals by primary and secondary treatment were significantly correlated with FIB densities in influent wastewater; however, meteorological conditions also influenced the removal of FIB.  相似文献   
3.
The toxic effect of a combined sewer overflow (CSO) on the phytoplankton community of the river Seine has been studied by means of short-term primary production measurements. As the discharged solids usually do not remain in the water column, only filtered or centrifugated fractions were tested. The collected phytoplankton were grown in the laboratory for 2 days, after addition of N, P and EDTA. Stock cultures in exponential growth were directly tested with heavy metals, but resuspended algal cells were used for effluent testing. The results show an increase of EC50 value for the single metal species in the order Cu相似文献   
4.
Physical, chemical and microbiological efficiencies of Sewage Treatment Plants (STPs) located in Delhi's watershed in context of different treatment technologies employed in these plants have been determined. There were in all seventeen STPs treating domestic wastewater which were studied over a period of 12 months. These STPs were based on Conventional Activated sludge process (ASP), Extended aeration (Ex. Aeration), physical, chemical and biological removal treatment (BIOFORE) and oxidation pond treatment process. Results suggests that except "Mehrauli" STP which was based on Extended aeration process and "Oxidation pond", effluents from all other STPs exceeded FC standard of 10(3) MPN/100 ml for unrestricted irrigation criteria set by National river conservation directorate (NRCD). Actual integrated efficiency (IE(a)) of each STP was evaluated and compared with the standard integrated efficiency (IE(s)) based upon physical, biological and microbiological removal efficiencies depending upon influent sewage characteristics. The best results were obtained for STPs employing extended aeration, BIOFORE and oxidation pond treatment process thus can be safely used for irrigation purposes.  相似文献   
5.
In order to obtain representative dissolved and solid samples from the aquatic environment, a spectrum of sampling methods are available, each one with different advantages and drawbacks. This article evaluates the use of discrete sampling and time-integrated sampling in illustrating medium-term spatial and temporal variation. Discrete concentration index (CI) calculated as the ratio between dissolved and solid metal concentrations in grab samples are compared with time-integrated concentration index (CI) calculated from suspended particulate matter (SPM) collected in sediment traps and labile metals measured by the diffusive gel in thin films (DGT) method, collected once a month during one year at the Seine River, upstream and downstream of the Greater Paris Region. Discrete CI at Bougival was found to be significantly higher than at Triel for Co, Cu, Mn, Ni and Zn, while discrete metal partitioning at Marnay was found to be similar to Bougival and Triel. However, when using time-integrated CI, not only was Bougival CI significantly higher than Triel CI, CI at Marnay was also found to be significantly higher than CI at Triel which was not observed for discrete CI values. Since values are time-averaged, dramatic fluctuations were smoothed out and significant medium-term trends were enhanced. As a result, time-integrated concentration index (CI) was able to better illustrate urbanization impact between sites when compared to discrete CI. The impact of significant seasonal phenomenon such as winter flood, low flow and redox cycles was also, to a certain extent, visible in time-integrated CI values at the upstream site. The use of time-integrated concentration index may be useful for medium- to long-term metal studies in the aquatic environment.  相似文献   
6.
Semi-permeable membrane devices (SPMDs) are passive samplers that have been designed to sample the bioavailable fractions of hydrophobic organic compounds in aquatic ecosystems. This study aims at evaluating the ability for SPMD to sample polycyclic aromatic hydrocarbons (fluoranthene, pyrene and benzo[a]pyrene) that are actually bioavailable to Daphnia magna. For that purpose, the SPMD-available fraction and the bioavailable fraction to D. magna are compared in controlled media with Dissolved Organic Matters (DOMs) from various origins and at different concentrations. The presence of all but one DOM reduces the accumulation of PAHs in SPMD or in D. magna. Moreover, this comparative laboratory study shows that in 10 cases on 13, the SPMD-available fraction is close to the available fraction to D. magna. When significant differences are observed between SPMD-available and bioavailable fractions, they remain less than 50% at DOM concentrations below 10 mg/l DOC, which corresponds to a maximum DOC concentration usually found in temperate rivers. This study confirms the suitability of the SPMD technique to monitor readily bioavailable hydrophobic contaminants in aquatic environments containing DOM from various origins and characteristics.  相似文献   
7.
Book reviews     
  相似文献   
8.
Pesticide uses and transfers in urbanised catchments   总被引:1,自引:0,他引:1  
An investigation on herbicide uses in two semi-urban catchments was performed simultaneously with sampling campaigns at six stations inside both watersheds from April to July 1998. Urban uses of herbicides exceeded agricultural uses, and transfer coefficients were also higher in urban areas. Therefore, the most used product in urban areas (diuron) was by far the most contaminating product. Householders accounted for 30% of all uses. The highest measured diuron concentration in water surface was 8.7 microg l(-1) due to its use on impervious surfaces. Compared to EEC standards for drinking water production (0.1 microg l(-1)), it is clear that suburban uses of herbicides may severely endanger drinking water production from river water.  相似文献   
9.
Sand dunes are complex systems that contain several habitats, often as mosaics or transitions between types. Several of these habitats are afforded protection under European Legislation and in the UK nationally within Special Areas of Conservation (SAC) and Sites of Special Scientific Interest (SSSI). Natural England has a statutory duty to report to Europe on the conservation status and condition of sand dunes; and is required to report to the UK Government on designated sites. To achieve this we have sought ways of capturing, analysing and interpreting data on the extent and location of sand dune habitats. This requires an ability to be able to obtain data over large areas of coastline in an efficient way. Natural England and Environment Agency Geomatics have worked collaboratively for over 16 years, sharing data and ecological knowledge. In 2012 work started to evaluate the use of remote sensing to map UK BAP and Annex I sand dune habitats. A methodology has now been developed and tested to map sand dune habitats. The key objective was to provide an operational tool that will help to map these habitats and understand change on sites around England. This has been achieved through analysis of LIDAR and Compact Airborne Spectrographic Imager (CASI) data using Object Orientated Image Analysis. Quality Control (QC) and accuracy assessments have shown this approach to be successful and 11 sites have been mapped to date. These techniques are providing a new approach to monitoring change in coastal vegetation communities and informing management of protected sites.  相似文献   
10.
A combination of reverse osmosis (RO) concentration and DAX-8/XAD-4 resin adsorption techniques is used to isolate the various constituents of urban dissolved organic matter (DOM) from inorganic salts. Three fractions: hydrophobic (HPO), transphilic (TPI) and hydrophilic (HPI) accounting respectively for 35%, 20% and 45% of extracted carbon, are isolated from effluents of a major French wastewater treatment plant. This atypical DOC distribution, in comparison with natural water where the HPO fraction dominates, shows the significance of HPI fraction which often gets neglected because of extraction difficulties. A number of analytical techniques (elemental, spectroscopic: UV, FTIR) allow highlighting the weak aromaticity of wastewater effluent DOM (EfOM) due to fewer degradation and condensation processes and the strong presence of proteinaceous structures indicative of intense microbial activity. Copper toxicity in the presence of DOM is estimated using an acute toxicity test on Daphnia Magna (Strauss). Results reveal the similar protective role of each EfOM fraction compared to reference Suwannee river fulvic acid despite lower EfOM aromaticity (i.e. specific UV absorbance). The environmental implications of these results are discussed with respect to the development of site-specific water quality criteria.  相似文献   