首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
安全科学   1篇
污染及防治   4篇
社会与环境   1篇
  2019年   1篇
  2013年   2篇
  2003年   1篇
  2001年   1篇
  1985年   1篇
排序方式: 共有6条查询结果,搜索用时 15 毫秒
1
1.
ABSTRACT

A laboratory thermal desorption apparatus was used to measure emissions from a number of nominally identical photocopier toners—manufactured to meet the specifications of one specific model copier—when these toners were heated to fuser temperature (180-200 °C). The objective was to assess how potential volatile organic compound (VOC) emissions from the toner for a given copier can vary, depending upon the production run and the supplier. Tests were performed on a series of toner (and associated raw polymer feedstock) samples obtained directly from a toner manufacturer, representing two production runs using a nonvented extrusion process, and on toner cartridges purchased from two local retailers, representing three different production lots (histories unknown). The results showed that the retailer toners consistently had up to 350% higher emissions of some major compounds (expressed as |ig of compound emit-ted/g of toner), and up to 100% lower emissions of others, relative to the manufacturer toners (p ≤ 0.01). The manufacturer toners from one production run had emissions of certain compounds, and of total VOCs, that were modestly higher (13-18%) than those from the other run (p ≤ 0.01). The emission differences between the retailer and manufacturer toners are probably due to differences  相似文献   
2.
Objectives: The Alcohol Use Disorders Identification Test (AUDIT) is used to assess the level of alcohol use/misuse and to inform the intensity of intervention delivered within screening, brief intervention, and referral to treatment (SBIRT) programs. Policy initiatives are recommending delivery of SBIRT within health care settings to reduce alcohol misuse and prevent alcohol-impaired driving. Recent reports are considering extending delivery of SBIRT to criminal justice settings. One consideration in implementing SBIRT delivery is the question of resource utilization; the amount of effort required in delivering the 4 different intensities of intervention in SBIRT: Alcohol education, simple advice, brief counseling and continued monitoring, and brief counseling and referral to specialist (from least to most intense in terms of delivery time, the skill level of the provider, and personnel resources).

Methods: In order to inform expectations about intervention intensity, this article describes the AUDIT scores from 982 adults recently arrested for alcohol-impaired driving. The distribution of scores is extrapolated to state rates for individuals arrested for alcohol-impaired driving by intervention level.

Results: Though alcohol education was the most common intervention category, about one quarter of the sample scored in a range corresponding with the more intensive interventions using the brief counseling, continued monitoring for ongoing alcohol use, and/or referral to specialist for diagnostic evaluation and treatment.

Conclusions: This article provides local distribution of AUDIT scores and state estimates for the number of individuals scoring in each level of risk (AUDIT risk zone) and corresponding intervention type. Routine criminal justice practice is well positioned to deliver alcohol screening, education, simple advice, and continued alcohol monitoring, making delivery of SBIRT feasible for the majority of alcohol-impaired drivers. Challenges to implementing the full range of SBIRT services include resource demands of brief counseling, identifying the appropriate providers within a criminal justice context, and availability of community providers for referral to diagnostic and specialty care. Solutions may vary by state due to differences in population density and incidence rates of alcohol-impaired driving.  相似文献   

3.
A survey of cesium residues in fish from the Savannah River near the Savannah River Nuclear Plant was undertaken in 1983. Fish tissues, bone, fin, and muscle were incubated by the wet disgestion method for analysis. Seventeen fish samples were analyzed by flame atomic absorption spectrophotometry procedure to determine cesium content. It was found that cesium concentration levels were consistently higher in the bones and fins than in muscles of all fish species. It seems that cesium concentration levels were relatively higher in fins than in bones. Cesium concentration levels in muscle tissues were negligible in all fish species.  相似文献   
4.
A laboratory thermal desorption apparatus was used to measure emissions from a number of nominally identical photocopier toners--manufactured to meet the specifications of one specific model copier--when these toners were heated to fuser temperature (180-200 degrees C). The objective was to assess how potential volatile organic compound (VOC) emissions from the toner for a given copier can vary, depending upon the production run and the supplier. Tests were performed on a series of toner (and associated raw polymer feedstock) samples obtained directly from a toner manufacturer, representing two production runs using a nonvented extrusion process, and on toner cartridges purchased from two local retailers, representing three different production lots (histories unknown). The results showed that the retailer toners consistently had up to 350% higher emissions of some major compounds (expressed as microgram of compound emitted/g of toner), and up to 100% lower emissions of others, relative to the manufacturer toners (p < or = 0.01). The manufacturer toners from one production run had emissions of certain compounds, and of total VOCs, that were modestly higher (13-18%) than those from the other run (p < or = 0.01). The emission differences between the retailer and manufacturer toners are probably due to differences in the manufacturing processes and/or feedstocks used to produce the toners from these different sources.  相似文献   
5.
ABSTRACT

Alkyd paint continues to be used indoors for application to wood trim, cabinet surfaces, and some kitchen and bathroom walls. Alkyd paint may represent a significant source of volatile organic compounds (VOCs) indoors because of the frequency of use and amount of surface painted. The U.S. Environmental Protection Agency (EPA) is conducting research to characterize VOC emissions from paint and to develop source emission models that can be used for exposure assessment and risk management. The technical approach for this research involves both analysis of the liquid paint to identify and quantify the VOC contents and dynamic small chamber emissions tests to characterize the VOC emissions after application. The predominant constituents of the primer and two alkyd paints selected for testing were straight-chain alkanes (C9–C12); C8–C9 aromatics were minor constituents. Branched chain alkanes were the predominant VOCs in a third paint. A series of tests were performed to evaluate factors that may affect emissions following application of the coatings. The type of substrate (glass, wallboard, or pine board) did not have a substantial impact on the emissions with respect to peak concentrations, the emissions profile, or the amount of VOC mass emitted from the paint. Peak concentrations of total volatile organic compounds (TVOCs) as high as 10,000 mg/m3 were measured during small chamber emissions tests at 0.5 air exchanges per hour (ACH). Over 90% of the VOCs were emitted from the primer and paints during the first 10 hr following application. Emissions were similar from paint applied to bare pine board, a primed board, or a board previously painted with the same paint. The impact of other variables, including film thickness, air velocity at the surface, and air-exchange rate (AER) were consistent with theoretical predictions for gas-phase, mass transfer-controlled emissions. In addition to the alkanes and aromatics, aldehydes were detected in the emissions during paint drying. Hexanal, the predominant aldehyde in the emissions, was not detected in the liquid paint and was apparently an oxidation product formed during drying. This paper summarizes the results of the product analyses and a series of small chamber emissions tests. It also describes the use of a mass balance approach to evaluate the impact of test variables and to assess the quality of the emissions data.  相似文献   
6.
Tests were conducted using 53-L dynamic chambers to determine airborne styrene emission rates over time from freshly copied paper. Copies were produced on a single photocopier using two toners manufactured for this copier but having different styrene contents. The resulting emission models were used to predict whether indoor styrene concentrations resulting from copied paper in a typical office might be significantly reduced by use of a low-emitting toner for a given copier. The styrene emissions were best represented by either a 3rd-order decay model or by a power law model having an exponent between 0.3 and 0.5 (R2 = 0.94-0.99). The two toners resulted in copied paper having significantly different styrene emissions (p < 0.01), with unit mass emissions over 1000 hr being nine times greater with the higher-emitting toner. But copied paper is predicted to produce peak indoor styrene concentrations in a typical office no more than 1% of the World Health Organization health-based guideline. Thus, for the toners considered here, indoor styrene exposures from copied paper appear to be too limited to provide incentive for switching to the lower-emitting toner. The ability to generalize these conclusions is limited by the fact that only one copier and two toners could be tested.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号