首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   8篇
  免费   0篇
废物处理   1篇
综合类   2篇
基础理论   1篇
污染及防治   3篇
评价与监测   1篇
  2020年   1篇
  2011年   1篇
  2010年   1篇
  2007年   2篇
  2004年   1篇
  1994年   1篇
  1986年   1篇
排序方式: 共有8条查询结果,搜索用时 15 毫秒
1
1.
Lead has been found to depress the immune system in animal studies at levels far below those responsible for overt toxicity. Literature studies in animal systems most clearly showed an effect of lead on response to a specific immunogenic stimulus. Data are sparse concerning the effects of lead on the immune system in the human population at greatest risk for exposure-children up to six years of age. This portion of the Phase I study reports concentrations of IgG, IgM, IgA, and IgE, as well as antibody titers to the specific antigenic stimuli provided by the vaccines against diphtheria, tetanus, and Rubella. The study population consisted of a group of 193 children, ages 9 months to 6 years, who participate in the WIC (Women, Infants and Children) and Lead Poisoning Prevention Programs in the urban area of Springfield-Greene County Missouri. Blood lead levels ranged from 1 to 50 g dL–1. Total Ig levels were determined and the data were analysed. No consistent significant differences were observed among the risk categories in the five age groups examined. A single Ig class in each of three age groups showed apparent significant differences among the various risk categories, but these differences were not correlated with blood lead. An analysis of specific antibody titers to diphtheria, tetanus, and Rubella was performed. Regression analyses of current data in Phase I of this study suggest a detrimental effect of lead on the antibody titres to diphtheria and Rubella.  相似文献   
2.
3.
4.
The extent of noise in five printing companies in Novi Sad, Serbia, was determined using TES-1358A Sound Analyzer with RS-232 Interface. The data on equivalent A-level (dBA), as well as, maximum and minimum sound pressure levels were collected. It was found that folders and offset printing units are the predominant noise sources, with the average L (eq) levels of 87.66 and 82.7 dBA, respectively. Forty percent of the machines produced noise levels above the limiting threshold level of 85 dBA, allowed by law. The noise in all printing companies was dominated by higher frequency noise, and the maximum level mostly appeared at 4,000 Hz. For offset printing machines and folders, the means of L (eq) levels exceeded the permissible levels given by NR-80 curve at higher frequencies. There are no published studies of occupational noise and hearing impairment of workers exposed to hazardous noise in printing industry in Serbia. More extensive studies are needed to determine the exact impact of noise on the workers. Technical and organizational measures in order to control noise and prevent noise exposure, and general hearing conservation program to protect workers, should be introduced in printing industry.  相似文献   
5.
Drugs inducing different forms of P-450 cytochrome isoenzymes and binding the Ah receptor or not were investigated for their ability to modify 2,3,7,8, tetrachlorodibenzo-p-dioxin (TCDD) immunotoxicity in mice. 3-Methyl-cholanthrene (3MC) and β-naphthoflavone (BNF) administered to TCDD-treated mice caused additive inhibition of humoral antibody production and of responsiveness to concanavallin A (ConA) but not to phytohemagglutinin (PHA) and lipopolisaccharide (LPS) while phenobarbital (PB) never modified TCDD immunosuppression. Natural killer (NK) cell activity was not reduced by single drug treatment or by combined treatments. Hepatic aryl hydrocarbon hydroxylase (AHH) induction by TCDD was not significantly modified by PB, 3MC or BNF.  相似文献   
6.
Remediation of heavy metals contaminated soils by ball milling   总被引:2,自引:0,他引:2  
Montinaro S  Concas A  Pisu M  Cao G 《Chemosphere》2007,67(4):631-639
In the present work, the use of ball milling reactors for the remediation of lead contaminated soils was investigated. Lead immobilization was achieved without the use of additional reactants but only through the exploitation of weak transformations induced on the treated soil by mechanical loads taking place during collisions among milling media. The degree of metal immobilization was evaluated by analyzing the leachable fraction of Pb(II) obtained through the "synthetic precipitation leaching procedure". The reduction of leachable Pb(II) from certain synthetic soils, i.e., bentonitic, sandy and kaolinitc ones, was obtained under specific milling regimes. For example, for the case of bentonitic soils characterized by a Pb(II) concentration in the solid phase equal to 954.4 mg kg(-1), leachable Pb(II) was reduced, after 7 h of mechanical treatment, from 1.3 mg l(-1) to a concentration lower than the USEPA regulatory threshold (i.e., 0.015 mg l(-1) for drinkable water). Similar results were obtained for sandy and kaolinitic soils. X-ray diffraction, scanning electron microscopy, electron dispersive spectroscopy and granulometric analyses revealed no significant alterations of the intrinsic character of sandy and bentonitic soils after milling except for a relatively small increase of particles size and a partial amorphization of the treated soil. On the other hand, the mechanical treatment caused the total amorphization of kaolinitic soil. The increase of immobilization efficiency can be probably ascribed to specific phenomena induced by mechanical treatment such as entrapment of Pb(II) into aggregates due to aggregation, solid diffusion of Pb(II) into crystalline reticulum of soil particles as well as the formation of new fresh surfaces (through particle breakage) onto which Pb(II) may be irreversibly adsorbed.  相似文献   
7.
The odour impact of a composting plant situated in an urbanized area was evaluated by continuously monitoring the ambient air close to the plant during a period of about 4 days using two electronic noses. One electronic nose was installed in a nearby house, and the other one inside the perimeter of the composting plant in order to compare the response of both instruments. The results of the monitoring are represented by tables that report the olfactory class and the odour concentration value attributed to the analyzed air for each of the 370 measurements carried out during the monitoring period. The electronic nose installed at the house detected the presence of odours coming from the composting plant for about 7.8% of the monitoring total duration. Of the odour detections, 86% (25 of 29 measurements) were classified as belonging to the olfactory class corresponding to the open air storage of the waste screening overflows heaps, which was therefore identified to be the major odour source of the monitored composting plant. In correspondence of the measurements during which the electronic nose inside the house detected the presence of odours from the composting plant, the olfactory classes recognized by both instruments coincide. Moreover, the electronic nose at the house detected the presence of odours from the composting plant at issue in correspondence of each odour perception of the house occupants. The results of the study show the possibility of using an electronic nose for environmental odours monitoring, which enables the classification of the quality of the air and to quantify the olfactory nuisance from an industrial source in terms of duration and odour concentration.  相似文献   
8.
This work discusses how it is possible to assess odour impact in presence of multiple similar sources by illustrating a case study. The study was conducted on an area of northern Italy comprising three small municipalities where four rendering plants are located near to each other. Based on the emission data resulting from olfactometric surveys conducted in different periods of the year the overall odour emission rate emitted by each plant were evaluated, showing that the major contributor to the odour impact on the territory was plant 2. These data were linked with meteorological and orographical data in order to evaluate odour dispersion with a model (Calpuff). The results of the odour dispersion modelling confirmed the outcomes of the olfactometric survey and they were further validated through a “questioning” survey, conducted with the aim of involving the population by means of questionnaires for reporting the perceived odour episodes, which showed a good correspondence (86.5%) between odour perceptions and simulated odour immissions.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号