Farideh Golbabaei Maryam Mamdouh Keramat Nouri Jelyani Seyed Jamaleddin Shahtaheri 《International journal of occupational safety and ergonomics》2005,11(3):283-289
Exposure to methyl methacrylate (MMA), total dust and health symptoms were investigated in 20 dental laboratories located in Tehran, Iran. Time-weighted average (TWA) of MMA and peak concentrations were determined, using XAD-2 tubes followed by GC-FID analysis. Total dusts were evaluated gravimetrically. Health symptoms were asked using a questionnaire. TWA for technicians with direct and indirect exposure to MMA were 327.28 +/- 79.42 and 282.9 +/- 41.84 mg/m3, respectively. Peak concentration of MMA for those technicians were 337.0 +/- 36.81 and 328.88 +/- 45.40 mg/m3, respectively. There were no significant differences between TWA of MMA and peak concentration in different weekly workdays; however, within-day variations were observed (P < .05). TWA of MMA and peak concentration correlation with the laboratory volume were 0.61-0.65. Dust exposure of technicians was 2.35 +/- 2.70 mg/m3. Cough and skin dryness were the common health symptoms. Smoking and asbestos exposure history were factors influencing cough prevalence (p < .05). It is concluded that the current Short-Term Exposure Limit (STEL) is not low enough to protect technicians against the adverse effects caused by MMA. 相似文献
2.
Solid phase extraction for evaluation of occupational exposure to Pb (II) using XAD-4 sorbent prior to atomic absorption spectroscopy. 总被引:2,自引:0,他引:2
Seyed Jamaleddin Shahtaheri Monireh Khadem Farideh Golbabaei Abbas Rahimi-Froushan Mohammad Reza Ganjali Parviz Norouzi 《International journal of occupational safety and ergonomics》2007,13(2):137-145
Lead is an important constituent widely used in different industrial processes. For evaluation of workers' exposure to trace toxic metal of Pb (II), solid-phase extraction (SPE) was optimized. SPE using mini columns filled with XAD-4 resin was developed with regard to sample pH, ligand concentration, loading flow rate, elution solvent, sample volume, elution volume, the amount of resins, and sample matrix interferences. Lead ions were retained on a solid sorbent and then eluted, followed by a simple determination of analytes with flame atomic absorption spectrometery. The obtained recoveries of metal ions were greater than 92%. This method was validated with 3 different pools of spiked urine samples; it showed a good reproducibility over 6 consecutive days as well as 6 within-day experiments. This optimized method can be considered successful in simplifying sample preparation for a trace residue analysis of lead in different matrices when evaluating occupational and environmental exposures is required. 相似文献
3.
Hossein Kakooei Seyed Jamaleddin Shahtaheri Hossein-Ali Karbasi 《International journal of occupational safety and ergonomics》2006,12(4):443-449
Evaluation of personal inhalation exposure to methylene diphenyl diisocyanate (MDI) among 39 employees, working in the window fixation and window glue processes in an automobile manufacturing company was performed. This study was conducted for both case and control groups. After sampling and sample preparation processes, MDI was determined with a UV-VIS spectrophotometer at 590 nm; the lung function was assessed with a digital spirometer, too. The average concentration of MDI in the window fixation, and window glue workplaces were 34.53 and 27.37 micro g/m3, respectively, which was lower than the threshold limit value (TLV) recommended by the American Conference of Governmental Industrial Hygienists (ACGIH) (51 micro g/m3). Respiratory symptoms in the exposed group were significantly different compared to the unexposed group (p < .05). Lung capacities in the case group were lower than in the control group (p < .05). Therefore, MDI can be easily measured making it possible to evaluate the adverse effects caused by occupational exposure. 相似文献
4.
Farideh Golbabaei Maryam Mamdouh Keramat Nouri Jelyani Seyed Jamaleddin Shahtaheri 《International journal of occupational safety and ergonomics》2013,19(3):283-289
Exposure to methyl methacrylate (MMA), total dust and health symptoms were investigated in 20 dental laboratories located in Tehran, Iran. Time-weighted average (TWA) of MMA and peak concentrations were determined, using XAD-2 tubes followed by GC-ID analysis. Total dusts were evaluated gravimetrically. Health symptoms were asked using a questionnaire. TWA for technicians with direct and indirect exposure to MMA were 327.28 ± 79.42 and 282.9 ± 41.84 mg/m3 , respectively. Peak concentration of MMA for those technicians were 337.0 ± 36.81 and 328.88 ± 45.40 mg/m3, respectively.There were no significant differences between TWA of MMA and peak concentration in different weekly workdays; however, within-day variations were observed (P < .05).TWA of MMA and peak concentration correlation with the laboratory volume were 0.61-0.65. Dust exposure of technicians was 2.35 ± 2.70 mg/m3. Cough and skin dryness were the common health symptoms. Smoking and asbestos exposure history were factors influencing cough prevalence (p < .05).It is concluded that the current Short-Term Exposure Limit (STEL) is not low enough to protect technicians against the adverse effects caused by MMA. 相似文献
5.
Seyed Jamaleddin Shahtaheri Farhad Ghamari Farideh Golbabaei Abbas Rahimi-Froushani Mohsen Abdollahi 《International journal of occupational safety and ergonomics》2013,19(4):377-388
Factors affecting solid phase extraction (SPE) of trans,trans-muconic acid (ttMA), as a benzene biomarker, including sample pH, sample concentration, sample volume, sample flow rate, washing solvent, elution solvent, and type of sorbent were evaluated. Extracted samples were determined by HPLC-UV(highperformance liquid chromatography-ultraviolet). The analytical column was C18, UV wave length was 259 nm, and the mobile phase was H2O/methanol/acetic acid run at flow rate of 1 ml/min. A strong anion exchange silica cartridge was found successful in simplifying SPE. There was a significant difference between recoveries of ttMA when different factors were used (p < .001). An optimum recovery was obtained when sample pH was adjusted at 7. There was no significant difference when different sample concentrations were used (p > .05). The optimized method was then validated with 3 different pools of samples showing good reproducibility over 6 consecutive days and 6 within-day experiments. 相似文献
6.
Khoshakhlagh Amir Hossein Beygzadeh Mojtaba Golbabaei Farideh Saadati Zohreh Carrasco-Marín Francisco Shahtaheri Seyed Jamaleddin 《Environmental science and pollution research international》2020,27(35):44022-44035
Environmental Science and Pollution Research - In the present paper, micro-mesoporous Fe-MIL-101/OAC composite using in situ incorporation of Fe-MIL-101 into oxidized activated carbon was... 相似文献
7.
Seyed Jamaleddin Shahtaheri Farhad Ghamari Farideh Golbabaei 《International journal of occupational safety and ergonomics》2005,11(4):377-388
Factors affecting solid phase extraction (SPE) of trans,trans-muconic acid (ttMA), as a benzene biomarker, including sample pH, sample concentration, sample volume, sample flow rate, washing solvent, elution solvent, and type of sorbent were evaluated. Extracted samples were determined by HPLC-UV (high performance liquid chromatography-ultraviolet). The analytical column was C18, UV wave length was 259 nm, and the mobile phase was H(2)O/methanol/acetic acid run at flow rate of 1 ml/min. A strong anion exchange silica cartridge was found successful in simplifying SPE. There was a significant difference between recoveries of ttMA when different factors were used (p < .001). An optimum recovery was obtained when sample pH was adjusted at 7. There was no significant difference when different sample concentrations were used (p > .05). The optimized method was then validated with 3 different pools of samples showing good reproducibility over 6 consecutive days and 6 within-day experiments. 相似文献