首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
污染及防治   3篇
评价与监测   2篇
社会与环境   1篇
  2016年   1篇
  2015年   1篇
  2009年   2篇
  2008年   1篇
  2007年   1篇
排序方式: 共有6条查询结果,搜索用时 15 毫秒
1
1.

The influence of the presence of the so-called seed particles on the emission rate of Tris (1-chloroisopropyl) phosphate (TCIPP) from polyisocyanurate (PIR) insulation boards was investigated in this study. Two Field and Laboratory Emission Test cells (FLEC) were placed on the surface of the same PIR board and respectively supplied with clean air (reference FLEC) and air containing laboratory-generated soot particles (test FLEC). The behavior of the area-specific emission rates (SER A ) over a time period of 10 days was studied by measuring the total (gas?+?particles) concentrations of TCIPP at the exhaust of each FLEC. The estimated SER A of TCIPP from the PIR board at the quasi-static equilibrium were found to be 0.82 μg m?2 h?1 in the absence of seed particles, while the addition of soot particles led to SER A of 2.16 μg m?2 h?1. This indicates an increase of the SER A of TCIPP from the PIR board with a factor of 3 in the presence of soot particles. The TCIPP partition coefficient to soot particles at the quasi-static equilibrium was 0.022?±?0.012 m3 μg?1. In the next step, the influence of real-life particles on TCIPP emission rates was investigated by supplying the test FLEC with air from a professional kitchen where mainly frying and baking activities took place. Similar to the reference FLEC outcomes, SER A was also found to increase in this real-life experiment over a time period of 20 days by a factor 3 in the presence of particles generated during cooking activities. The median value of estimated particle–gas coefficient for this test was 0.062?±?0.037 m3 μg?1.

  相似文献   
2.
3.
A diffusive sampling method for the determination of gaseous acetic and formic acids, using a radial symmetry diffusive sampler, has been optimised for a 7-day exposure time in this study. Sampling rate determinations were performed on data obtained from a dynamic exposure chamber, simulating the indoor conditions of an empty, closed, room, at room temperature and minimal wind speed. Analysis has been performed by means of ion chromatography. The sampling rates for formic acid concentrations of 128 microg m(-3) and 1248 microg m(-3) were determined to be 91.2 +/- 3.9 ml min(-1) and 111.6 +/- 2.8 ml min(-1), respectively. The acetic acid sampling rate was independent of the concentration in the range 160 microg m(-3)-1564 microg m(-3), and amounted to 97.3 +/- 3.1 ml min(-1). Experimentally determined sampling rates showed deviations of 3% for acetic acid, and 3-21% for formic acid, in relation to theoretically derived values. The blank values were as low as 1.69 +/- 0.07 microg for formic acid and 1.21 +/- 0.14 microg for acetic acid, and detection limits lower than 0.5 microg m(-3) could be achieved, which is an improvement of 98-99% compared to previously validated diffusive sampling methods. This study describes the first step of an extended validation program in which the applicability of these types of samplers for the measurement of organic acids will be validated and optimised for the environmental conditions typical for museum showcases.  相似文献   
4.
The major threat to clean air in developed and industrializing countries is now posed by traffic emissions. The effects of traffic road modifications on the air quality are, however, rarely reported in the literature. The aim of this study was to determine the influence of the modernization and renovation of a traffic artery in the region of Mortsel (Antwerp, Belgium) on the concentration of volatile organic compounds such as: benzene, toluene, ethylbenzene and m-, p-, o-xylenes (BTEX). The original goal of the reconstruction works was to reduce the traffic lanes of one of the busiest streets in Antwerp, in order to discourage the road traffic and in consequence also to improve the air quality in this region. The average concentrations of BTEX before these works in 2003 were: 1.6, 7.0, 0.9, 2.3, and 0.9 μg/m3, for benzene, toluene, ethylbenzene, m + p xylenes, and o-xylene, respectively. However, after the completion of the works, in 2005, they were slightly higher: 2.5, 9.5, 1.6, 3.4, and 1.3 μg/m3, respectively. The scatter plots of benzene against toluene, ethylbenzene and xylenes in 2003 and 2005 showed very good correlations. This fact indicated that all of the measured compounds originated from the same source, namely the road traffic. Moreover, the data obtained from an air-monitoring station at less than 6 km distance from the sampling site (operated by the Flemish Environment Agency, and located in Borgerhout, Antwerp), confirmed the lack of influence of background concentrations of BTEX. The obtained results led to the conclusion that the reduction of the number of traffic lanes had apparently increased the traffic jams and also increased the emission from cars. Therefore, these modernization works had even a negative impact on the local concentration of traffic-related pollutants as BTEX.  相似文献   
5.
Comparative overview of indoor air quality in Antwerp, Belgium   总被引:2,自引:0,他引:2  
This comprehensive study, a first in Belgium, aimed at characterizing the residential and school indoor air quality of subgroups that took part in the European Community Respiratory Health Survey and the International Study of Asthma and Allergy in Childhood [Masoli M, Fabian D, Holt S, Beasley R. Global Burden of Asthma, Medical Research Institute of New Zealand, University of Southampton; 2004.] questionnaire-based asthma and related illnesses studies. The principal aim was to perform a base-line study to assess the indoor air quality in Antwerp in terms of various gaseous and particulate pollutants. Secondly, it aimed to establish correlations between these pollutants investigated, the pollutant levels in the indoor and outdoor micro-environments, findings of the previous questionnaire-based studies and an epidemiological study which ran in conjunction with this study. Lastly, these results were compared and evaluated with current indoor and ambient guidelines in various countries This paper presents selected results on PM1, PM2.5 and PM10 mass concentrations and elemental C estimates as black smoke, as well as gaseous NO(2), SO(2), O(3) and BTEX concentrations of 18 residences and 27 schools. These are related to current guidelines of Flanders, Germany, Norway, China and Canada and evaluated with reference to selected similar studies. It was found that indoor sources such as tobacco smoking and carpets, the latter causing re-suspension of dust, are responsible for elevated indoor respirable particulate matter and place school children and residents at risk. Both PM2.5 and PM10 equalled or exceeded the current guidelines adopted by Flanders, noting that 12-h and 24-h PM2.5 were compared with an annual limit value. Indoor and ambient NO(2) concentrations in the school campaign were higher than the annual EU ambient norm. The other studied pollutant levels were below the current guidelines.  相似文献   
6.
Atmospheric aerosols can consist of, amongst others, compounds like NH(4)NO(3) or (NH(4))(2)SO(4). Such components can suffer radiation damage and/or evaporate during EDXRF measurements, providing errors on successively applied analysis. The aim of this work is to investigate the influence of measurements using conventional EDXRF on the volatile compounds and to compare it with the influence of polarized beam EDXRF using secondary targets (and hence indirect irradiation). The effect of different parameters (acquisition time, accelerating voltage, current and medium) on the concentration loss was studied. The measurements performed in vacuum during a long period lead to the highest losses of volatile compounds. The influence of direct irradiation was proved to be larger than the indirect variant.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号