排序方式: 共有3条查询结果,搜索用时 0 毫秒
1
1.
Brouwers MM Besselink H Bretveld RW Anzion R Scheepers PT Brouwer A Roeleveld N 《Environment international》2011,37(3):557-564
Measurements of estrogenic and androgenic activities in total plasma with Chemically Activated LUciferase gene eXpression (CALUX?) bioassays could provide biologically relevant measures for exposure to endocrine disruptors in epidemiologic studies. The objective of this study was to explore the effects of a variety of sources of potential endocrine disruptors on estrogenic and androgenic activities in total plasma measured by CALUX?. Plasma samples and interview data on sources of potential endocrine disruptors were collected from 108 men with different exposures profiles. CALUX? measurements (BioDetection Services) involved human U2-OS cell lines controlled by the estrogen receptor alpha and the androgen receptor. Mean differences (beta) in 17β-estradiol equivalents (EEQs) and dihydrotestosterone equivalents (AEQs) between exposure groups were estimated using general linear models. Mean plasma AEQs and EEQs were 9.1×10(-1)ng/ml and 12.0pg/ml, respectively. Elevated AEQs were found in smokers (beta 1.9 (95%CI 0.1-3.6)×10(-1)ng/ml) and heavy drinkers (1.4 (0.2-3.1)×10(-1)ng/ml), and in men occupationally exposed to disinfectants (1.6 (0.3-3.5)×10(-1)ng/ml) or welding/soldering fumes (1.4 (-0.2-2.9)×10(-1)ng/ml). Occupational exposure to pesticides, disinfectants, and exhaust fumes seemed to be associated with increased plasma EEQs: 1.5 (-0.2-3.2)pg/ml, 2.1 (0.2-3.9)pg/ml, and 2.9 (0.6-5.2)pg/ml, respectively. Moderate to high plasma dioxin levels, measured in a subgroup by the dioxin-responsive CALUX?, were accompanied by a 20% increase in AEQs. This is the first study in which CALUX? was used to assess hormone activities in total plasma. Although the results are not yet readily interpretable, they indicate that these measurements can be valuable for epidemiologic studies on endocrine disruptors and give direction for further research. 相似文献
2.
Scheepers PT Cremers R van Hout SP Anzion RB 《Journal of environmental monitoring : JEM》2012,14(2):429-439
During periods of two weeks in February and June 2010 the performance of portable air treatment units (PATUs) was evaluated in a primary school classroom using indicators of indoor air quality. Air samples were collected in an undisturbed setting on weekend days and in an occupied setting during teaching hours. In the first week PATUs were turned off and in the second week they were turned on. On weekend days PATUs reduced indoor levels of PM-10 by 87% in February and by 70% in June compared to weekend days when PATUs were turned off. On schooldays, indoor PM-10 was increased by 6% in February and reduced by 42% in June. For PM-2.5 reductions on weekend days were 89% in February and 80% in June. On school days PM-2.5 was increased by 15% in February and reduced by 83% in June. Turning on the PATUs reduced total VOC by 80% on weekend days and by 57% on school days (but not in June). No influence on formaldehyde, NO(2), O(3) and molds was observed. PATUs appeared to be less effective in removal of air pollutants when used in an occupied classroom compared to an unoccupied setting. Our study suggests that such devices should be tested in real-life settings to evaluate their influence on indoor air quality. 相似文献
3.
中国煤中氟的含量及其分布 总被引:18,自引:1,他引:18
在全国主要产煤的26个省、市和自治区根据各煤田的地质储量、成煤时期和煤变质程度,兼顾各矿区的煤炭产量,采集305个煤样,用高温热水解-离子选择性电极法测定了全部样品的氟含量.煤中的氟主要以无机形态赋存,氟含量和变质程度之间没有必然的联系.成煤时代等单一因素对氟含量的影响可能为其它各种因素的综合作用所掩盖,对此有必要进行更深入、具体的研究研究了各省、市和自治区的煤氟含量的分布,有必要重新审视、甄别燃煤型氟中毒区氟的来源.全国煤的氟含量服从对数正态分布,90%的样品含氟范围为47~347mg/kg,宜用几何平均值136mg/kg作为全国平均煤氟含量.与世界煤相比,中国煤氟含量并无异常. 相似文献
1