首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   86篇
  免费   1篇
  国内免费   1篇
废物处理   5篇
环保管理   5篇
综合类   14篇
基础理论   12篇
污染及防治   42篇
评价与监测   6篇
社会与环境   4篇
  2023年   2篇
  2022年   12篇
  2021年   11篇
  2020年   3篇
  2019年   5篇
  2018年   3篇
  2017年   6篇
  2016年   8篇
  2015年   7篇
  2014年   7篇
  2013年   9篇
  2012年   3篇
  2011年   4篇
  2009年   1篇
  2007年   1篇
  2005年   1篇
  2002年   1篇
  1996年   1篇
  1995年   1篇
  1993年   1篇
  1985年   1篇
排序方式: 共有88条查询结果,搜索用时 0 毫秒
1.
The interaction of the phototoxic alkaloid coralyne with bovine and human serum albumins (BSA, HSA) was investigated. Absorbance and fluorescence quenching experiments revealed the formation of strong complexes. Based on the binding parameters calculated from Stern-Volmer quenching method, coralyne has higher affinity to BSA (∼105 M−1) compared to HSA (∼104 M−1). Forster resonance energy transfer studies showed that the specific binding distances between Trp (donor) of the proteins and coralyne (acceptor) were 2.95 and 3.10 nm, respectively. The bindings were favored by negative enthalpy and a stronger favorable entropy contribution. The heat capacity values for binding to BSA and HSA were similar, indicating the involvement of similar molecular forces in the complexation. Competitive binding experiments using site markers demonstrated that coralyne binds to site I (subdomain IIA) of both proteins. The secondary structure of the proteins was altered, suggesting a small but definitive partial unfolding on complexation.  相似文献   
2.
In the present paper, the optimum design of a PV system used to operate a water pumping system was determined for Oman. The system design focused on the environmental conditions of Sohar city. The implementation and measurement of the designed system are presented to prove the effectiveness of the proposed system. The results show that the system can provide the required power at peak hours, leading to a substantial reduction in the sizing of the PV system. Consequently, the investment capital costs 2400 USD, and the cost of energy is equal to 0.309 USD/kWh. Furthermore, the results indicate that the system annual yield factor is 2024.66 kWh/kWp and that the capacity factor is 23.05 %, which is encouraging since the latter is typically 21 %. The system capital cost and the cost of energy are worth comparing to a diesel generator. A comparison is made between the proposed system and several others in the literature. The comparison indicated that the system cost of energy is promising.  相似文献   
3.
Environmental Science and Pollution Research - Strategic valorization of readily available sugarcane bagasse (SB) is very important for waste management and sustainable biorefinery. Conventional SB...  相似文献   
4.
Environmental Science and Pollution Research - In northern Tunisia, Sidi Driss sulfide ore valorization had produced a large waste amount. The long tailings exposure period and in situ minerals...  相似文献   
5.
Hydrogen cyanide (HCN) poisoning due to amygdalin (AMY) in apricot seeds is one of the public health issues in Turkey. The aim of this study was to investigate the AMY content of 13 different apricot seeds including bitter and sweet ones, and which are either sulfurized or roasted. The AMY content was determined by a high-performance liquid chromatography. Release of HCN was predicted and total amount of seeds which can cause poisoning was calculated. The mean AMY content of bitter seeds was 26 ± 14 mg g?1 and that of sweet seeds was 0.16 ± 0.09 mg g?1. The consumption of small amounts of bitter seeds may cause cyanide poisoning.  相似文献   
6.
In this study, an experimental investigation on the performance of a small-scale residential-size solar-driven adsorption (silica gel-water) cooling system that was constructed at Assiut University campus, Egypt is carried out. As Assiut area is considered as hot, arid climate, field tests for performance assessment of the system operation during the summer season are performed under different environmental operating conditions. The system consists of an evacuated tube with a reflective concentration parabolic surface solar-collector field with a total area of 36 m2, a silica gel-water adsorption chiller of 8 kW nominal cooling capacity, and hot and cold water thermal storage tanks of 1.8 and 1.2 m3 in volume, respectively. The results of summer season field test show that under daily solar insolation varying from 21 to 27 MJ/m2, the solar collectors employed in the system had high and almost constant thermal efficiency. The daily solar-collector efficiency during the period of system operation ranged from about 50% to 78%. The adsorption chiller performance shows that the chiller average daily coefficient of performance (COP) was 0.41 with the average cooling capacity of 4.4 kW when the cooling-water and chilled-water temperatures were about 31°C and 19°C, respectively. As the chiller cooling water is cooled by the cooling tower in the hot arid area, the cooling water is at a higher temperature than the design point of the chiller. Therefore, an experiment was carried out using the city water for cooling. The results show that an enhancement in the chiller COP by 40% and the chilling power by 17% has been achieved when the city water was 27.7°C.  相似文献   
7.
Environmental Science and Pollution Research - The instant endeavor was undertaken to monitor copper (Cu) contents in water, soil, forage, and cow’s blood impacted by heavy automobiles in...  相似文献   
8.
9.
10.
Journal of Material Cycles and Waste Management - Effective municipal solid waste collection and disposal system is not possible without reliable solid waste generation and classification data...  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号