首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   5篇
  免费   0篇
污染及防治   3篇
评价与监测   2篇
  2010年   1篇
  2007年   1篇
  2003年   2篇
  1989年   1篇
排序方式: 共有5条查询结果,搜索用时 0 毫秒
1
1.
When Saccharomyces cerevisiae was cultured in the presence of thorium, the element was accumulated by the cells and was visible in electron micrographs as electron dense granules. When thorium was present during exponential growth, these granules were located mainly in the vacuole, with some present in the cytosol. Where thorium was present only during the stationary phase, there appeared to be greater thorium deposition in the cell wall than during exponential growth and some vacuolar deposits were also evident. Thorium uptake by exponential-phase cells was not stimulated by glucose and was thus independent of metabolic energy.  相似文献   
2.
In this report, we have identified oxalic acid as an important metabolite elaborated in the response of wood-rotting fungi to toxic metal stress. The formation of oxalate crystals by white rot fungi (Bjerkandera fumosa, Phlebia radiata and Trametes versicolor) and the brown rot fungus Fomitopsis pinicola, grown on media containing high levels of toxic metal ions has been visualized using scanning electron microscopy (SEM) with energy-dispersive X-ray micro-analysis (EDXA) and HPLC. There were no significant differences between the growth of controls (metal-free) and on the 0.5% CaCO(3), Co(3)(PO(4))(2) or Zn(3)(PO(4))(2)-amended plates. ZnO inhibited the growth of all strains. Crystals were not detected in Zn(3)(PO(4))(2)-amended plates. The four examined strains displayed the formation of crystals on ZnO, Co(3)(PO(4))(2) and CaCO(3)-amended plates.  相似文献   
3.
Agricultural wastes are a source of steroid estrogens and, if present, conjugated estrogens may add to the estrogen load released to soil and aquatic environments. Dairy shed effluent samples were collected from 18 farms for analysis of steroid estrogens by GC-MS, conjugated estrogens by LC-MS-MS, and estrogenic activity by E-screen in vitro bioassay. 17α-estradiol was found at highest concentrations (median 730 ng l−1), followed by estrone (100 ng l−1) and 17β-estradiol (24 ng l−1). Conjugated estrogens (estrone-3-sulfate, 17α-estradiol-3-sulfate and 17β-estradiol-3,17-disulfate) were measured in most samples (12-320 ng l−1). Median estrogenic activity was 46 ng l−1 17β-estradiol equivalents. Conjugated estrogens contributed up to 22% of the total estrogen load from dairy farming, demonstrating their significance. Steroid estrogens dominated overall estrogenic activity measured in the samples. Significantly, 17α-estradiol contributed 25% of overall activity, despite potency 2% that of 17β-estradiol, highlighting the importance in environmental risk assessments of this previously neglected compound.  相似文献   
4.
A biochemical oxygen demand (BOD) monitoring system, based on electrochemically-active bacteria in combination with a microbial fuel cell, has been developed for the purpose of on-site, on-line and real-time monitoring of practical wastewater. A microbial fuel cell that had been enriched with electrochemically-active bacteria was used as the basis of the measurement system. When synthetic wastewater was fed to the system, the current generation pattern and its Coulombic yield were found to be dependent on the BOD5 of the synthetic wastewater. A linear correlation between the Coulombic yields and the BOD5 of the synthetic wastewater were established. Real wastewater obtained from a sewage treatment plant also produced a highly linear correlation between the Coulombic yield and BOD5 in the system. To examine on-site, on-line and real-time monitoring capability, the BOD monitoring system was installed at a sewage treatment plant. Over 60 days, the measurement system was successfully operated with high accuracy and good stability with the measuring period for a sample being 45 min. This application showed that the application of the measurement system was a rapid and practical way for the determination of BOD5 in water industries.  相似文献   
5.
A novel biomonitoring system using microbial fuel cells   总被引:2,自引:0,他引:2  
A novel biomonitoring system using microbial fuel cells for detecting the inflow of toxic substances into water systems has been developed for the purpose of on-site and on-line monitoring. The characteristics of electric current generation by electrochemically-active bacteria were conveniently monitored using a microbial fuel cell format and a computer-controlled potentiometer. When toxic substances (an organophosphorus compound, Pb, Hg, and PCBs) were added to the microbial fuel cell, rapid decreases in the current were observed. The inhibition ratios caused by inflow of these toxic substances (1 mg l(-1)) were 61%, 46%, 28% and 38%, respectively, when compared to the control, and generally increased in proportion to the addition time and concentration of toxic substances. When real wastewater was applied from a local wastewater treatment plant, more significant current decreases and higher inhibition ratios were observed following the introduction of toxic substances than in the laboratory tests. For example, the inhibition ratio was 76% on addition of a 1 mg l(-1) Cd and 1 mg l(-1) Pb mixture. Application of the microbial fuel cell for pollutant biomonitoring is discussed.  相似文献   
1